Flush Switch, 1 Gang, 250VAC, 10A, Architrave

White Electric | Flush Switch, 1 Gang, 250VAC, 10A, Architrave

Flush Switch, 1 Gang, 250VAC, 10A, Architrave

Item Number: 30-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Device presentation

basic element with full cover plate and grid

Switch function

1-pole

Number of rocker

1

Number of poles

1

Device mounting

flush

Fixing mode

by screws

Local signalling

without

[Ue] rated operational voltage

250 V AC

Rated current

10 A

Marking

without marking

Actuator

rocker

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

0.03 kg

Package 1 Height

3 cm

Package 1 width

3.3 cm

Package 1 Length

7.5 cm

Unit Type of Package 2

BB1

Number of Units in Package 2

10

Package 2 Weight

0.35 kg

Package 2 Height

8.6 cm

Package 2 width

7.1 cm

Package 2 Length

16.7 cm

Unit Type of Package 3

CAR

Number of Units in Package 3

250

Package 3 Weight

8.75 kg

Package 3 Height

23.8 cm

Package 3 width

34.2 cm

Package 3 Length

39 cm
Show all specifications

Documents & downloads

hide show

Frequently Asked Questions

hide show

Video: How is a faulted Altivar drive reset?

Issue:
Reset a  fault on a Altivar drive.

Product Line:
Altivar ATV variable speed drives

Environment:
All

Cause:
Need to reset a fault status.

Resolution:
There are multiple ways to reset a fault, including a logic input assignment and communication network.  But an easy way to reset a fault is to remove line voltage from L1,L2,L3.  Allow enough time for the display to go completely blank and then wait another 30seconds.  Reapply power.  If the fault appears again, it means that the VFD has refaulted.

Note: Some faults have to be reset by removing and reapplying line voltage (power-cycling) the drive. Refer to your drive's Programming Manual for a list of faults that require a power cycle to clear. 

The following video demonstrates how to configure a logic input fault reset function on the Altivar 212:

Can I replace a broken toggle on an NS / NSX circuit-breaker or switch.?

No, the toggle on the breaker frame cannot be replaced as the toggle is integral to the breaker frame.

The breaker frame needs to be replaced.

However, the toggle extension (4 to 5 cm long piece screwed to the toggle) can be replaced, but only if the toggle thread is not damaged.
 
If the thread is damaged the breaker frame needs to be replaced.

For the NSX up to  250A - Part number is LV429313
For the NSX 400A to 630A - Part number is LV432553
 

What is the operating temperature range of the C60H circuit-breakers ?

The C60H circuit-breaker operating temperature range is between -30°C to +70°C.

Will an FAL or FHL breaker that has an electrical accessory such as shunt trip, undervoltage trip, auxiliary switch, or alarm switch fit into a standard FA enclosure?

Issue:  
Need to know if my FAL breaker will install in an enclosure with an accessory installed in it.  

Product line:  
Molded case circuit breakers

Resolution:  
Yes. These accessories are internal to the breaker frame and require no extra enclosure room.  

What is the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38?

Issue:
LC1D09 - LC1D38 Coil tolerance

Product Line:
Contactors and Starters, IEC

Environment:
Tesys D Contactors

Cause:
Needs the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38.

Resolution:
AC single frequency coils: 50Hz and 60 Hz (-20% / +10%);
AC dual frequency coils: 50Hz (-20% / +10%) ; 60Hz (-15% / +10%)
DC standard coil for LC1D09 -D38 and LC1DT20 to DT40: (-30% / +25%)
DC standard coil for LP1D12 and D25: (-20% / +10%)
DC wide range coil for LP1D12 and D25 : (-30% to +25%)

Can I connect aluminium or copper, flexible or rigid cables to the single and double terminals of the NSX 400 to 630 range.?

In the NSX 400 to 630 range:

Single terminals, part numbers LV432479 or LV432480, can take: aluminium or copper rigid cables with cross-section 35 to 300 mm² and flexible cables with cross-section 240 mm² maximum.

Double terminals, part numbers LV432481 or LV432482, can take: aluminium or copper rigid cables with cross-section 35 to 240 mm² and flexible cables with cross-section 185 mm² maximum.
Show More