bracket mounting for conduit

Cable Management Fixing Accessories, Corrugated Conduit Clamp and Bracket, 20mm

Catalogue Number: 280C20
bracket mounting for conduit
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
clamp and bracket
Material
PVC (polyvinyl chloride)
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Are the Clipsal Conduit Clips available in Electric Orange?

No, they are only available in grey.

This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

Can I order the 220/20 in white?

Yes, you can order the 220/20 in white but it needs to be done as a special.
For more information, please refer to the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=220/20

Is the Clipsal 279C20 20 mm Gland UV rated ?

 No  - only UV stabalised

Is there a black version of the 220S20?

Yes, there is.  The 220S20 comes in 3 colors.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=220S20 

Air flow for ATV78 from 200kw up to 710kw

Goals and Symptoms

For our costumer in the M30 project that are going to buy some ATV78, they are asking me about the flow of the fans necessary for the enclousure, in the catalog page 38 it apeears up to 160kw, and I need for the powers from 200 to 710kw high torque

Causes and Fixes

From ATV 780C20Y to ATV 780C31Y -> air cooling: 2600m3/h
From ATV 780C35Y to ATV 780C50Y -> air cooling: 3900m3/h
From ATV 780C56Y to ATV 780C71Y -> air cooling: 5200m3/h


Legacy KB System (APS) Data: RESL180523 V1.0, Originally authored by on , Last Edited by YoBl on 01/16/2007
Related ranges: Altivar 78

Video: What is the default grid snap setting in Vijeo Designer v6.2?

The default spacing is 20x20 pixels.  It can also be changed from the Graphical Panels Properties.

The following video demonstrates adjusting the grid snap spacing in Vijeo Designer via the Graphical Panels Property Inspector.

 

Wrench Icon flickers on the Series 700 or 200 Power Meter (PM200 or PM700)

Product Line
PM700 Series
PM200 Series

Environment
Firmware

Cause
A possible reason for the flickering wrench icon to occur is a relatively low load of approximately 500 to 525 mA RMS being applied on the current inputs of the PM200 or PM700 (with firmware version 2.020 or previous). This low load will cause the gain change to flip back and forth between low and high gain. This causes the wrench icon to flicker on and off due to clipping during high gain at the transition point.

Firmware version 3.050 or later will check the peak amplitude prior to changing from low gain to high gain and delay the transition to high gain to prevent clipping.

Resolution
The Series 700 and 200 Power Meters with firmware 2.020 requires a firmware update to version 3.050 or above.

To verify the firmware version from the front panel of the meter, press MAINT > INFO for the PM700 and press DIAGN > INFO for the PM200.

See FA237920 for latest firmware, firmware upload software, and instruction on how to upgrade the firmware.

Using Modbus to trigger a Waveform Capture on a CM2000

Product Line
CM2000 series meter

Environment
Modbus Register Writes

Resolution
In order to trigger a waveform capture, it will be necessary to use Modbus Command Writes to trigger the waveform capture.

Using Modbus Tester (or another Modbus read/write program):

Write the value 4913 to register 7700.
Write the value 1 to register 7701.
Write the value 28120 to register 7702.

Why are PM700s pulse weights different on different PM700s?

Issue
Some PM700 have the possibility for adjusting pulse weight to 0.01 kWh/pulse even though the documentation says the minimum value that can be set is 0.1 kWh/pulse.

Product Line
PM700

Environment
Firmware

Cause
OS 2.020 added a higher amount of accuracy for the pulse weight option.

Resolution
With firmware OS 2.020, the lowest pulse weight value that can be set on the meter was reduced from 0.1 to 0.01kWh/pulse. That is to say, starting from firmware version OS 2.020, lowest pulse weight option is now 0.01 kWh/pulse instead of .1 kWh/pulse. 

IP protection and gas

Goals and Symptoms

Need to know if the power part with IP54 degree of protection (where is placed the heatsink), of Altivar 71 and 31 is proof (resistant) against the following chimical compound: NPK 8/24/24 - PK 9x36 - UREA 46% N - H8 N2 O4S - PK 14x24 - PK 20x20 - Mg SO4 7 H2O - KC1 60% K2O - K2 SO4 50% K2O - (NH4) 2 HPO4 - NH4 H2 PO4 - Ca (H2 PO4) 2 and "ammonium nitrate" with a percetage of nitrogen. I apologize for the "strange" question but I kindly ask you help for to give an answer to our customer. Please take care of this request ASAP because is very urgent (our PAE should give an answer for tomorrow).

Facts and Changes

heatsink

Causes and Fixes

Attached is a document with the protection again gas for our drive. The standard IEC721-3-3 is taken as a reference.

Where can I get support for APC and MGE Products?

For support on APC and MGE products please visit:  https://www.apc.com/support/

AC Power
Additional Management Cards and Options
Air Cooled Chillers
Air Distribution Accessories
Airflow Management
AIS 3000
AIS 5000
AIS Accessories
AIS Battery Systems
APC CS
APC Enterprise Manager
APC ES
APC RS
Application Shutdown Utilities
Assessment Services
Auto and Air Inverters
AV Accessories
AV Power Conditioners & Battery Backups
AV Power Filters
AV Pro Interconnects
AV Surge Protectors
Backpacks and Messenger Bags
Back-UPS
Back-UPS Accessories
Back-UPS BI
Back-UPS CS
Back-UPS ES
Back-UPS HI
Back-UPS HT
Back-UPS LS
Back-UPS Office
Back-UPS Pro
Back-UPS RS
Back-UPS XS
Basic Rack PDU
Battery Management
Battery Replacement Services
Biometric Security
Bulk Cable
Cabinet Power Distribution
Cable Management
Charge-UPS EX
Commercial/Industrial Surge Suppression
Condensers
Configurable Power Accessories
Configurable Power Distribution
Console Port Servers
CyberFort
Data Center Facility Cooling - Andover Continuum or TAC Vista
Data Center Facility Power - PowerLogic ION Enterprise
Data Center Software Integration Kits
Data Center University
Data Distribution Cable
DC Battery
DC Components
DC Distribution Components
DC600
Desktop KVM
Desktop Notebook Stands
EcoBreeze Air Economizers
Environmental Management System
Environmental Monitoring Unit
Ethernet Switches
Extended Warranties
Fiber Optics
Firmware Upgrades
FLM Series
Fluid Coolers
FRP/Ferroresonant Power Supply
Game Console Surge Protection
Gender Changers
Global Deployment
Hardwire Surge Suppression Accessories
High-Density Cooling Enclosures
IDE Cables
IEEE1394
Industrial
InfraStruxure for Large Data Centers
InfraStruxure for Medium Data Centers
InfraStruxure for Server Rooms
InfraStruxure for Small Data Centers
InfraStruxure for Wiring Closets
InfraStruxure Manager
InfraStruxure Type A
InRoom Direct Expansion
InRow Chilled Water
InRow Direct Expansion
InRow Pumped Refrigerant
Installation Services
Interface Cables
International Plug Adapters
Keyboard
KVM Switches
Laptop Power Adapters
Line-R
Magnum VS
Magnum XS
Magnum XS Rectifier
Maintenance Bypass Panels
Management Platform Integration
Matrix Battery Systems
Matrix-UPS
Matrix-UPS Accessories
Metered Rack PDU
Metered-by-Outlet Rack PDU
MGE Accessories
MGE Alpes
MGE Battery Systems
MGE Comet
MGE EPS
MGE EPS 6000
MGE EPS 7000
MGE EPS 8000
MGE Galaxy
MGE Galaxy 300
MGE Galaxy 3000
MGE Galaxy 3500
MGE Galaxy 4000
MGE Galaxy 5000
MGE Galaxy 5500
MGE Galaxy 6000
MGE Galaxy 7000
MGE Galaxy 9000
MGE Galaxy PW
MGE Legacy
MGE Service Bypass
MGE Sinewave
MGE Static Transfer Switches
MGE UPS 4000
Microsol Estabilizadores
Microsol Modules Isoladores
Mobile Notebook Stands
Modular Components
Modular Power Accessories
Modular Power Distribution
Monitor
Mounting Hardware
Mouse
MRC1800
MRE2400
Multimedia
MWF1700
NetBotz 200
NetBotz 300
NetBotz 400
NetBotz 500
NetBotz Access Control
NetBotz Accessories and Cables
NetBotz Central
NetBotz Rack Access
NetBotz Sensors
NetShelter CX
NetShelter EP Enclosures
NetShelter ES Enclosures
NetShelter Open Frame Rack Accessories
NetShelter SX
NetShelter VL
NetShelter VS Enclosures
NetShelter VX Enclosures
Network Integration Services
Network Patch Cables
NetworkAIR Accessories
NetworkAIR AFX
NetworkAIR CM
NetworkAIR CW
NetworkAIR FM
NetworkAIR IR
NetworkAIR TC
Notebook Security
On Site Service
Open Frame Racks
Operations Capacity
Operations Change
Operations Energy Cost
Operations Energy Efficiency
Operations Insight
Operations Mobile
Operations VIZOR
Outdoor Enclosures
Panelmount Environmental Monitoring
Parallel
Patch Panels
PC1200
Planning Tools and Publications
Portable Cooling
Power Cords
Power Distribution Units
Power Generation Systems
Power Ready Notebook Cases
PowerChute Business Edition
PowerChute Inventory Manager
PowerChute Network Shutdown
PowerChute Personal Edition
PowerChute plus
PowerManager
PowerShield
Preventive Maintenance
Project Management Services
ProtectNet
Rack Air Distribution
Rack Components
Rack LCD Consoles
Rack PDU Accessories
Rack-mount Transfer Switches
Refrigerant Distribution
Remote Monitoring Services
Replacement Batteries
Replacement Notebook Batteries
Residential Hardwire Surge Suppression
Retail
Retractable Cables
Room Air Distribution
Room Cooling Accessories
Router Cables
Row Cooling Accessories
SCSI
Security Cameras
Sensors
Serial
Service Bypass Panel
Service Plans
Silcon
Silcon Accessories
Silcon Battery Systems
SLM/FLM Series
SmartSlot Expansion Chassis
Smart-UPS
Smart-UPS Accessories
Smart-UPS Battery Systems
Smart-UPS DP
Smart-UPS On-Line
Smart-UPS RT
Smart-UPS VT
Software Configuration
Software Education
Software for NetBotz Appliances
Software Installation
Software Integration
Spare Part Kits
Specialty Enclosures
Start-Up Service
Stationary Power Distribution Units
Step-Down Transformer
StruxureWare Central
StruxureWare Operations Suite
SurgeArrest Essential
SurgeArrest Home/Office
SurgeArrest Notebook
SurgeArrest Performance
Switch Boxes
Switched Rack PDU
Symmetra
Symmetra Accessories
Symmetra Battery Systems
Symmetra MW
Symmetra MW Accessories
Symmetra Power Module
Symmetra PX
Symmetra PX Accessories
Sync and Charge Cables
Thermal Containment
Thick and Thin Ethernet
Token Ring
Toploading Cases
Traditional Cases
Training Services
Transceivers
Transportation
Travel Mice
TSP Accessories
TSP Battery
TSP/Generator
TSP/Total System Power
Tune-UPS for Symmetra
Uniflair Chilled Water
Universal Mobile Device Batteries
Universal Notebook Batteries
Universal Notebook Power Adapter
Universal Power Accessories
Universal Power Adapters
UPS Network Hub Card
UPS Network Management Cards
USB Adapters & Converters
USB Cables
USB Charging Cables
USB Hubs
Wall-mount Transfer Switches
Wheeled Cases
Wireless
Wizards and Configurators
WS200