clip conduit pvc 40mm

Fixing Accessories, PVC, Conduit Clips and Mounting Channel, Conduit Clip 40mm

Catalogue Number: 280/40
clip conduit pvc 40mm
Colour: Grey
Colour: Per UOM Std.
  • Grey 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Material
plastic
Length
49 mm
Width
12 mm
Height
46 mm
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Are the Clipsal Conduit Clips available in Electric Orange?

No, they are only available in grey.

This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

Typical 3-line drawings for Sepam Series 20, 40 and 80 current and voltage input connections

Goals and Symptoms

Typical 3-line drawings of Sepam 20/40 Feeder, Sepam 20/40 Main and Sepam 80 Main/Feeder.

Causes and Fixes

See attachment
Sepam.zip



AEDL3
Legacy KB System (APS) Data: RESL203669 V1.0, Originally authored by MiZe on 10/09/2010, Last Edited by MiZe on 10/09/2010
Related ranges: Sepam series 80, Sepam series 40, Sepam series 20

Can I order the 220/20 in white?

Yes, you can order the 220/20 in white but it needs to be done as a special.
For more information, please refer to the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=220/20

What is the part no for 40mm Screw caps

Part no 220S40 available as standard in Grey
Orange can be supplied as special

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=220S40
User-added image

Looking to replace the LXM23DU04M3X and BCH0602O12A1C

Issue:
Looking to replace the LXM23DU04M3X and BCH0602O12A1C servo motor

Product Line:
LXM23

Resolution:

The direct replacement is:
 
LXM28AU04M3X and BCH2LD0431CA5C combination:
 
- Supply voltage single phase 200/240 VAC or 3 phase 200/240 VAC, 50/ 60 Hz
- Nominal torque 1.27 Nm
- Maximum peak torque 3.81 Nm
- Nominal speed 3000 RPM
- 0.4 Kw motor rating
- 0.27 kgcm2 motor inertia without holding brake
 
You cannot copy the parameters from the old drive to the new drive. They will have to be entered manually in the new LXM28 drive.

What is the part number for a 50mm female and 50mm male bush?

The part number for a 50mm female and 50mm male bush is - 281/50 & 281F50
For further information , visit link below:-
www.clipsal.com/Trade/search-results?q=281/50
https://www.clipsal.com/Trade/search-results?q=281F50
User-added image

 

What is the replacement AC coil for CAD32 and CAD50 relay?

Issue:
Are replacement  AC coil available for CAD32 and CAD50 relay?

Product Line:
Tesys Relays

Environment:
All Products

Cause:
Product selection

Resolution:
Volt = coil part number
12 = LXD1J7
21 = LXD1Z7
24 = LXD1B7
32 = LXD1C7
36 = LXD1CC7
42 = LXD1D7
48 = LXD1E7
60 = LXD1EE7
100 = LXD1K7
110 = LXD1F7
115 = LXD1FE7
120 = LXD1G7
127 = LXD1FC7
200 = LXD1L7
208 = LXD1LL7
220/230 = LXD1M7
230 595 21 LXD1P7
230/240 = LXD1U7
277 781 30 LXD1W7
380/400 = LXD1Q7
400 = LXD1V7
415 = LXD1N7
440 = LXD1R7
480 = LXD1T7
600 = LXD1X7
690 = LXD1Y7

 

How do i seal up a 50mm hole in the 230DRAVL?

Using parts 220S50-GY and 260/50-GY. Placethe 260/50 on the inside and the 220S50 on the out side place it in the hole and screw them together. This willl then seal the hole.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=260/50
https://www.clipsal.com/Trade/Products/ProductDetail?catno=220S50
 
 
 

How can you configure the ATV32 drive to use assemblies 20/70 and 21/71?

Issue:
How can you configure the ATV32 drive to use assemblies 20/70 and 21/71?

Product Line:
Altivar ATV32

Environment:
ATV32 with Ethernet option card installed

Cause:
Set up configuration to use assemblies 20,21,70 and 71.

Resolution:
See case #2 example in the following attachment.
 

What is the part number of the surface mounting box that has a duct entry?

The part number of the surface mounting box that can accept a duct is 900SPMB. The 900SPMB is a standard pattern Surface Mounting Box for single gang accessories. Internal depth - 33mm.
Features: 4 - 25 x 16mm Trunking Entries, including one each end and side.
Supplied with 3 - Cat. No. 900MBC Clip-in/ push out caps, 4 - Cat. No. 220/10 Insulating Caps and 2 - M3.5 x 0.8 x 16mm long pan head screws. Screws thread into brass inserts.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=900SPMB

 

What are the part numbers of slip type expansion couplings?

Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
16mm = 251/16
20mm = 251/20 *
25mm = 251/25 *
32mm = 251/32
40mm = 251/40 *
* = only available in Grey
Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
Dimension details are attached.
 

Customer is looking for a sizing tool for Schneider Electric solar products.

Customers are looking for a sizing tool for there solar projects or installations with Schneider Electric products. 

We can provide the customer with a Conext Designer tool which includes the following products:

Conext TX inverters
Conext Core XC
Conext TL
Conext RL
Conext CL
XW-MPPT 80/60

Download link for the Conext Designer:
https://schneider-electric.box.com/s/g5yyi93prdtogi877yu2




 

Does the SEPAM MES 114/120 I/O module have analog input availability?

The Sepam MES114/120 I/O module does not have an input that can monitor the value of an analog signal generated from an external power source. The Sepam I/O modules are designed to detect status changes of a circuit breaker, contactor, plc, etc....., and will output a "0" or "1", depending on the condition of the input signal. The MES114 I/O module (compatible w/ Series 20/40) has up to 10 input connections and the MES120 (compatible w/ Series 80) has up to 14 input connections.
The Accessory MES114 and MES 120 can be used only in Logical Status

The MES114 module, on the other hand, will accept analog input signals, but the input APS_SENSORS will only detect whether the status of the analog signal is high "1" or low "0" depending on a certain threshold. These thresholds can be located in the characteristics section of the MES114 install sheet:


For a 110 V AC analog signal, a signal greater than 88V will force a "1" state and a signal less than 22V will force a "0" state.
For a 220 V AC analog signal, a signal greater than 176V will force a "1" state and a signal less than 48V will force a "0" state.

These input status changes can then be used by the Sepam relay to influence control logic, display alarm messages & LEDs, trigger waveforms or open & close relay outputs.

Nevertheless sepam can use the Accessory MSA 141 to manage an Analogic Output

AEDL3



 
Legacy KB System (APS) Data: RESL203471 V1.0, Originally authored by MiZe on 09/21/2010, Last Edited by MiZe on 09/21/2010
Related ranges: Sepam accessories

How does a basic pressure switch work?

Issue:
How does a basic pressure switch work?

Product Line:
Digest 177 Section 22 : Pressure, Vacuum and Float switches

Environment:
North American Products

Cause:
Operation clarification

Resolution:
The switch has a `turn ON` set point and a `turn OFF` set point. ie.a 20-40 switch turns ON at 20psi or below and turns OFF at40psi or above. This range or differential prevents contact chatter in electromechanical devices.

 

What is the part number for a Contactor with Low consumption?

The part number for a low consumption contactor is LC1D09.
General Product information:
Range of product TeSys D
Product or component type Contactor
Device short name LC1D
Contactor application Motor control Resistive load
Utilisation category AC-1, AC-3
Poles description 3P
Power pole contact composition 3 NO
[Ue] rated operational voltage <= 300 V DC for power circuit
<= 690 V AC 25...400 Hz for power circuit
[Ie] rated operational current 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
Motor power kW 5.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 500 V AC 50/60 Hz
4 kW at 415...440 V AC 50/60 Hz
4 kW at 380...400 V AC 50/60 Hz
2.2 kW at 220...230 V AC 50/60 Hz
Motor power HP (UL / CSA) 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
Control circuit type AC 50/60 Hz
Control circuit voltage 415 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A at <= 60 °C for signalling circuit
25 A at <= 60 °C for power circuit



For more information please visit https://www.schneider-electric.com.au/en/productcontaLC1D



When can CCA634 replace a CCA630?

Issue  
Need a new CCA63x but not sure which one I need.

Product Line
SEPAM 20 Series
SEPAM 40 Series
SEPAM 50 Series
SEPAM 80 Series

Resolution
Current transformer are connected to SEPAM series 20,40 and 80 through CCA630 or CCA634 connector.
Both are inclunding interposing CTs.

CCA630:
includes 3 interposing CTs to connect 2 or 3 phases CTs.  
If CSH30 is used CCA630 is needed

CCA634:
includes 4 interposing CTs :
3 to connect 3 phases CTs
1 for the residual current acquisition (CSH30 is now integrated in CCA634 for this function) :
- the sum of the 3 CTs
- an earth/ground CT

A new SEPAM base, adding a connection for Io channel on SubD 9 connector, is needed to accept the CCA634.

THIS NEW FEATURE HAS BEEN IMPLEMENTED STARTING :
series 20 : 1st week of 2003 S/N 0301001
series 40 : week 23 of 2006 S/N 0623001
series 80 : week 29 of 2006 S/N 0629001

As modification is hardware, no firmware update can change the situation for SEPAM made before these dates.

 

How to control the frequency of the VFD over the network when using output assembly 20 or 22 when using DeviceNet or Ethernet IP?

Issue: 
How to control the frequency of the VFD over the network when using output assembly 20 or 22 when using DeviceNet or Ethernet IP?
 
Product Line:
Altivar 61, Altivar 71
 
Environment:
All serial number
 
Cause:
VFD will not respond to speed control from the network when the reference channel is programmed to Comm card and the drive shows the active reference channel is Comm Card.
 
Resolution:
When using output assembly 20 or 22, by default, the Net Ref parameter is set to 0.  This parameter must be set to 1 in order to control the speed from the network for Devicnet or EtherNet IP.   The net ref parameter must be set on each time the VFD is powered.
Net Ref parameter 2A/1/4 = 1
The address can be set with the Class Instance Editor or with a message instruction block.

Where can I get support for APC and MGE Products?

For support on APC and MGE products please visit:  https://www.apc.com/support/

AC Power
Additional Management Cards and Options
Air Cooled Chillers
Air Distribution Accessories
Airflow Management
AIS 3000
AIS 5000
AIS Accessories
AIS Battery Systems
APC CS
APC Enterprise Manager
APC ES
APC RS
Application Shutdown Utilities
Assessment Services
Auto and Air Inverters
AV Accessories
AV Power Conditioners & Battery Backups
AV Power Filters
AV Pro Interconnects
AV Surge Protectors
Backpacks and Messenger Bags
Back-UPS
Back-UPS Accessories
Back-UPS BI
Back-UPS CS
Back-UPS ES
Back-UPS HI
Back-UPS HT
Back-UPS LS
Back-UPS Office
Back-UPS Pro
Back-UPS RS
Back-UPS XS
Basic Rack PDU
Battery Management
Battery Replacement Services
Biometric Security
Bulk Cable
Cabinet Power Distribution
Cable Management
Charge-UPS EX
Commercial/Industrial Surge Suppression
Condensers
Configurable Power Accessories
Configurable Power Distribution
Console Port Servers
CyberFort
Data Center Facility Cooling - Andover Continuum or TAC Vista
Data Center Facility Power - PowerLogic ION Enterprise
Data Center Software Integration Kits
Data Center University
Data Distribution Cable
DC Battery
DC Components
DC Distribution Components
DC600
Desktop KVM
Desktop Notebook Stands
EcoBreeze Air Economizers
Environmental Management System
Environmental Monitoring Unit
Ethernet Switches
Extended Warranties
Fiber Optics
Firmware Upgrades
FLM Series
Fluid Coolers
FRP/Ferroresonant Power Supply
Game Console Surge Protection
Gender Changers
Global Deployment
Hardwire Surge Suppression Accessories
High-Density Cooling Enclosures
IDE Cables
IEEE1394
Industrial
InfraStruxure for Large Data Centers
InfraStruxure for Medium Data Centers
InfraStruxure for Server Rooms
InfraStruxure for Small Data Centers
InfraStruxure for Wiring Closets
InfraStruxure Manager
InfraStruxure Type A
InRoom Direct Expansion
InRow Chilled Water
InRow Direct Expansion
InRow Pumped Refrigerant
Installation Services
Interface Cables
International Plug Adapters
Keyboard
KVM Switches
Laptop Power Adapters
Line-R
Magnum VS
Magnum XS
Magnum XS Rectifier
Maintenance Bypass Panels
Management Platform Integration
Matrix Battery Systems
Matrix-UPS
Matrix-UPS Accessories
Metered Rack PDU
Metered-by-Outlet Rack PDU
MGE Accessories
MGE Alpes
MGE Battery Systems
MGE Comet
MGE EPS
MGE EPS 6000
MGE EPS 7000
MGE EPS 8000
MGE Galaxy
MGE Galaxy 300
MGE Galaxy 3000
MGE Galaxy 3500
MGE Galaxy 4000
MGE Galaxy 5000
MGE Galaxy 5500
MGE Galaxy 6000
MGE Galaxy 7000
MGE Galaxy 9000
MGE Galaxy PW
MGE Legacy
MGE Service Bypass
MGE Sinewave
MGE Static Transfer Switches
MGE UPS 4000
Microsol Estabilizadores
Microsol Modules Isoladores
Mobile Notebook Stands
Modular Components
Modular Power Accessories
Modular Power Distribution
Monitor
Mounting Hardware
Mouse
MRC1800
MRE2400
Multimedia
MWF1700
NetBotz 200
NetBotz 300
NetBotz 400
NetBotz 500
NetBotz Access Control
NetBotz Accessories and Cables
NetBotz Central
NetBotz Rack Access
NetBotz Sensors
NetShelter CX
NetShelter EP Enclosures
NetShelter ES Enclosures
NetShelter Open Frame Rack Accessories
NetShelter SX
NetShelter VL
NetShelter VS Enclosures
NetShelter VX Enclosures
Network Integration Services
Network Patch Cables
NetworkAIR Accessories
NetworkAIR AFX
NetworkAIR CM
NetworkAIR CW
NetworkAIR FM
NetworkAIR IR
NetworkAIR TC
Notebook Security
On Site Service
Open Frame Racks
Operations Capacity
Operations Change
Operations Energy Cost
Operations Energy Efficiency
Operations Insight
Operations Mobile
Operations VIZOR
Outdoor Enclosures
Panelmount Environmental Monitoring
Parallel
Patch Panels
PC1200
Planning Tools and Publications
Portable Cooling
Power Cords
Power Distribution Units
Power Generation Systems
Power Ready Notebook Cases
PowerChute Business Edition
PowerChute Inventory Manager
PowerChute Network Shutdown
PowerChute Personal Edition
PowerChute plus
PowerManager
PowerShield
Preventive Maintenance
Project Management Services
ProtectNet
Rack Air Distribution
Rack Components
Rack LCD Consoles
Rack PDU Accessories
Rack-mount Transfer Switches
Refrigerant Distribution
Remote Monitoring Services
Replacement Batteries
Replacement Notebook Batteries
Residential Hardwire Surge Suppression
Retail
Retractable Cables
Room Air Distribution
Room Cooling Accessories
Router Cables
Row Cooling Accessories
SCSI
Security Cameras
Sensors
Serial
Service Bypass Panel
Service Plans
Silcon
Silcon Accessories
Silcon Battery Systems
SLM/FLM Series
SmartSlot Expansion Chassis
Smart-UPS
Smart-UPS Accessories
Smart-UPS Battery Systems
Smart-UPS DP
Smart-UPS On-Line
Smart-UPS RT
Smart-UPS VT
Software Configuration
Software Education
Software for NetBotz Appliances
Software Installation
Software Integration
Spare Part Kits
Specialty Enclosures
Start-Up Service
Stationary Power Distribution Units
Step-Down Transformer
StruxureWare Central
StruxureWare Operations Suite
SurgeArrest Essential
SurgeArrest Home/Office
SurgeArrest Notebook
SurgeArrest Performance
Switch Boxes
Switched Rack PDU
Symmetra
Symmetra Accessories
Symmetra Battery Systems
Symmetra MW
Symmetra MW Accessories
Symmetra Power Module
Symmetra PX
Symmetra PX Accessories
Sync and Charge Cables
Thermal Containment
Thick and Thin Ethernet
Token Ring
Toploading Cases
Traditional Cases
Training Services
Transceivers
Transportation
Travel Mice
TSP Accessories
TSP Battery
TSP/Generator
TSP/Total System Power
Tune-UPS for Symmetra
Uniflair Chilled Water
Universal Mobile Device Batteries
Universal Notebook Batteries
Universal Notebook Power Adapter
Universal Power Accessories
Universal Power Adapters
UPS Network Hub Card
UPS Network Management Cards
USB Adapters & Converters
USB Cables
USB Charging Cables
USB Hubs
Wall-mount Transfer Switches
Wheeled Cases
Wireless
Wizards and Configurators
WS200