terminator 90deg 20mm

Flexible Conduit Terminator, 2 Piece Angled 20mm Male Threadx16mm Plain Male End

Catalogue Number: 268AA
terminator 90deg 20mm
Colour: Black
Colour: Per UOM Std.
  • Black 1 PCE

Specifications

hide show
Product brand
Clipsal
Material
plastic
External diameter
  • 16 mm
  • 20 mm
    • Length
      53 mm
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP100802EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      Does the 26886 RCBO switch the Neutral

       The 26886 does NOT switch the Neutral

      Does the 26889 RCBO switch the neutral

       No it doesn't

      What can I use the 26888 RCBO for

       This RCBO is to protect machinery not people

      What is the replacement part for a 26896 RCB?

      The replacement part is a A9D61820.
      A9D11220 is best solution
      A9D11820 is an alternative 1 pole wide but no Neutral switching
      A9D61820 is an alternative 1 pole wide but no Neutral switching and only 6kA
       

      What is the Acti 9 replacement for the Multi 9 26888 RCBO?

      The replacement is the Acti 9 A9D11820

      Model   |   Current Rating   |   No. of poles   |   Sensitivity   |   Width in mod. of 9mm
      iC60H*   |            20A              |       1P + Ns        |      30mA         |                2

      What is the replacement for 26860 RCBO?

      The replacement for 26860 is A9D11820

      For more information see attachment:

      How are the Color Codes 568A and 568B different?

      Issue:
      The difference between T568A and T568B color codes is needed.

      Product Line:
      Cables and Connectivity Solutions, Patch Panels

      Environment:
      CAT6PNL-24 and CAT6PNL-48, all serial ranges. 

      Cause:
      Not following the correct color code can cause wiring errors.

      Answer: 
      568A and 568B are color code standards that show which color wire matches up with a specific position on an RJ45 connector. When designing a network infrastructure only one color code can be followed. All commercial and residential wiring in the US follows TIA 568B color code. Some Federal agencies had historically followed 568A, but many have changed to 568B. 

      T568B Color Code
      RJ45 Pin---Pair Color
      1-------------White/Orange
      2-------------Orange
      3-------------White/Green
      4-------------Blue
      5-------------White/Blue
      6-------------Green
      7-------------White/Brown
      8-------------Brown

      T568A Color Code
      RJ45 Pin---Pair Color
      1-------------White/Green
      2-------------Green
      3-------------White/Orange
      4-------------Blue
      5-------------White/Blue
      6-------------Orange
      7-------------White/Brown
      8-------------Brown

      Are APC Cat 6 Patch Panels color coded for 568B or 568A?

      Issue: 
      The installer needs to know the color code on the rear of the Cat 6 patch panel.  
       
      Product Line:
      Cables and Connectivity Solutions, Patch Panels
       
      Environment:
      CAT6PNL-24, CAT6PNL-48
       
      Cause:
      Installers need to know if the patch panel has the color code they require.
       
      Resolution : 
       
      The CAT6PNL-xx series of Patch Panels have both 568B and 568A color codes. Cat 5e, 6 and 6a patch cables and other cabling accessories can be viewed at www.apccables.com 

      ATV31 - ATV71 overvoltage threshold OSF.

      Issue:   ATV31 - ATV71 overvoltage threshold OSF.
       
      Product Line:   ATV31 ATV71
       
      Environment:  ATV71***N4 ATV31***N4
       
      Cause:   Overvoltage threshold
       
      Resolution:   
      Description: Line voltage too high
      OSF : overvoltage when the drive is not running
      OSF Fault cannot be automatically reset. The cause of the fault must be corrected before resetting by cycling the power:

      ATV71 OSF Thresholds:
      200V Range 400V range
      OSF high 269Vac 535Vac
      OSF low 265Vac 530Vac


      ATV31 OSF Thresholds:
      200V Range 400V range 500V range
      OSF high 283Vac 594Va 707Vac
      OSF low 268Vac 560Vac 670Vac


      Legacy KB System (APS) Data: RESL173050 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Altivar 71

      How do you read the color code on the IDC connectors of the Cat 6 Patch Panels?

      Issue:
      Customers may question which color code instructions to follow, 568B vs. 568A. Or they may not understand how to read the color code.

      Product Line:
      Cables and Connectivity Solutions, Cat 6 Patch Panels

      Environment:
      All versions and serial ranges.

      Cause:
      The color code instructions may be confusing.

      Resolution:
      For high speed networking 568B is used almost universally.
      If you need help determining how to terminate to the 568B or 568A color code please see the attached file.
       

      What is the part number for Saturn ZEN series two gang plate with Cat6 data mechanisms?

      Saturn ZEN series two gang plate with Cat6 data mechanisms can be built using the below part numbers:
      Z4032VH - Grid and Plate Assembly 2 Gang Saturn ZEN
      +
      2 off 30RJ45SMA6 - 30 Series Cat6 UTP Connector Mechanisms, Modular socket, 568A, RJ45.

      For further information, please visit the below links:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=Z4032VH

      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30RJ45SMA6

      How to Calculate the Required Capacity kVA Rating or Amperage Capacity for Single and Three Phase Transformers

      Issue:
      Calculation of kVA capacity for a Single or Three Phase Transformer, based on Winding Voltage and Amperage information.
       
       
      Environment:
      Applies to all Single and Three Phase Transformers.
       
      Cause:
      kVA sizing must often be calculated from Primary or Secondary Winding Voltage and Amperage information.
       
      Resolution:

      To determine kVA you must have at least two pieces of information:  

      1. the load line-to-line voltage (V)
      2. the maximum load phase current (I)

      Single Phase Transformers: kVA = (V * I) /1000
      Three Phase Transformers:  kVA = (V * I * 1.732) / 1000
      where 1.732 is the simple numerical value for the square root of 3 (1.7320508...)
      Then round up to the next standard 3ph kVA rating as found in Section 14 of SquareD/Schneider Electric Catalog, Digest 177.

      Single Phase Transformer Example: V = 240, I = 175; Therefore: kVA = (240 x 175) / 1000 = 42 kVA
      This calculates to 42 kVA, thus we round up to a standard Single Phase size 50kVA.  From the Digest, an EE50S3H will satisfactorily serve this load.

      Three Phase Transformer Example:  V = 208, I = 175; Therefore: kVA = (208 x 175 x 1.732) / 1000 = 63.05kVA
      This calculates to 63+ kVA, thus we round up to a standard Three Phase size 75kVA.  From the Digest, an EX75T3H will satisfactorily serve this load.

      Note:  This is a sample kVA calculation and does not take into account possible special load requirements, such as found with motors or some medical equipment, or other specialty applications.


      Amperage provided for a given KVA can be determined by similar techniques:

      Single Phase Example:  Using a 50 KVA Single Phase Transformer as a starting point.  50KVA is equal to 50,000 VA. (K= 1,000)  The full value in VA, 50,000 is then divided by the Voltage 240V = 208 Amperes.  This is a "Two Step Division", technique:  VA / Voltage = Amperage

      Three Phase Example:  Using a 75 KVA Three Phase Transformer as a starting point.  75 KVA is equal to 75,000 VA. (K= 1,000)  The full value in VA, 75,000 divided by 1.732 = 43,302, which is then divided by the Voltage 208V = 208.2 Amperes.  This is a "Three Step Division", technique:  VA / 1.732 / Voltage = Amperage


      As an alternative to these calculations, you may prefer to use the charts below.  Standard KVA sizes are shown on the left margin, Standard Line-to-Line Voltages are shown along the top margin. 

      Chart Example:  Using the numbers from the earlier Three Phase Transformer Example V=208, I=175.  Use the chart titled "Three Phase Low Voltage Dry Type Transformers".  Following the 208V top margin entry, and reading down vertically, it is seen that the first entry in that 208V vertical column that will cover 175A, and then some, is 208A, which indicates a 75 KVA Transformer, shown in the next over vertical column to the left.

      See attached document 7400HO9501 "Looking for Low Voltage Transformer Solutions" for more information.

      Where can I get support for APC and MGE Products?

      For support on APC and MGE products please visit:  https://www.apc.com/support/

      AC Power
      Additional Management Cards and Options
      Air Cooled Chillers
      Air Distribution Accessories
      Airflow Management
      AIS 3000
      AIS 5000
      AIS Accessories
      AIS Battery Systems
      APC CS
      APC Enterprise Manager
      APC ES
      APC RS
      Application Shutdown Utilities
      Assessment Services
      Auto and Air Inverters
      AV Accessories
      AV Power Conditioners & Battery Backups
      AV Power Filters
      AV Pro Interconnects
      AV Surge Protectors
      Backpacks and Messenger Bags
      Back-UPS
      Back-UPS Accessories
      Back-UPS BI
      Back-UPS CS
      Back-UPS ES
      Back-UPS HI
      Back-UPS HT
      Back-UPS LS
      Back-UPS Office
      Back-UPS Pro
      Back-UPS RS
      Back-UPS XS
      Basic Rack PDU
      Battery Management
      Battery Replacement Services
      Biometric Security
      Bulk Cable
      Cabinet Power Distribution
      Cable Management
      Charge-UPS EX
      Commercial/Industrial Surge Suppression
      Condensers
      Configurable Power Accessories
      Configurable Power Distribution
      Console Port Servers
      CyberFort
      Data Center Facility Cooling - Andover Continuum or TAC Vista
      Data Center Facility Power - PowerLogic ION Enterprise
      Data Center Software Integration Kits
      Data Center University
      Data Distribution Cable
      DC Battery
      DC Components
      DC Distribution Components
      DC600
      Desktop KVM
      Desktop Notebook Stands
      EcoBreeze Air Economizers
      Environmental Management System
      Environmental Monitoring Unit
      Ethernet Switches
      Extended Warranties
      Fiber Optics
      Firmware Upgrades
      FLM Series
      Fluid Coolers
      FRP/Ferroresonant Power Supply
      Game Console Surge Protection
      Gender Changers
      Global Deployment
      Hardwire Surge Suppression Accessories
      High-Density Cooling Enclosures
      IDE Cables
      IEEE1394
      Industrial
      InfraStruxure for Large Data Centers
      InfraStruxure for Medium Data Centers
      InfraStruxure for Server Rooms
      InfraStruxure for Small Data Centers
      InfraStruxure for Wiring Closets
      InfraStruxure Manager
      InfraStruxure Type A
      InRoom Direct Expansion
      InRow Chilled Water
      InRow Direct Expansion
      InRow Pumped Refrigerant
      Installation Services
      Interface Cables
      International Plug Adapters
      Keyboard
      KVM Switches
      Laptop Power Adapters
      Line-R
      Magnum VS
      Magnum XS
      Magnum XS Rectifier
      Maintenance Bypass Panels
      Management Platform Integration
      Matrix Battery Systems
      Matrix-UPS
      Matrix-UPS Accessories
      Metered Rack PDU
      Metered-by-Outlet Rack PDU
      MGE Accessories
      MGE Alpes
      MGE Battery Systems
      MGE Comet
      MGE EPS
      MGE EPS 6000
      MGE EPS 7000
      MGE EPS 8000
      MGE Galaxy
      MGE Galaxy 300
      MGE Galaxy 3000
      MGE Galaxy 3500
      MGE Galaxy 4000
      MGE Galaxy 5000
      MGE Galaxy 5500
      MGE Galaxy 6000
      MGE Galaxy 7000
      MGE Galaxy 9000
      MGE Galaxy PW
      MGE Legacy
      MGE Service Bypass
      MGE Sinewave
      MGE Static Transfer Switches
      MGE UPS 4000
      Microsol Estabilizadores
      Microsol Modules Isoladores
      Mobile Notebook Stands
      Modular Components
      Modular Power Accessories
      Modular Power Distribution
      Monitor
      Mounting Hardware
      Mouse
      MRC1800
      MRE2400
      Multimedia
      MWF1700
      NetBotz 200
      NetBotz 300
      NetBotz 400
      NetBotz 500
      NetBotz Access Control
      NetBotz Accessories and Cables
      NetBotz Central
      NetBotz Rack Access
      NetBotz Sensors
      NetShelter CX
      NetShelter EP Enclosures
      NetShelter ES Enclosures
      NetShelter Open Frame Rack Accessories
      NetShelter SX
      NetShelter VL
      NetShelter VS Enclosures
      NetShelter VX Enclosures
      Network Integration Services
      Network Patch Cables
      NetworkAIR Accessories
      NetworkAIR AFX
      NetworkAIR CM
      NetworkAIR CW
      NetworkAIR FM
      NetworkAIR IR
      NetworkAIR TC
      Notebook Security
      On Site Service
      Open Frame Racks
      Operations Capacity
      Operations Change
      Operations Energy Cost
      Operations Energy Efficiency
      Operations Insight
      Operations Mobile
      Operations VIZOR
      Outdoor Enclosures
      Panelmount Environmental Monitoring
      Parallel
      Patch Panels
      PC1200
      Planning Tools and Publications
      Portable Cooling
      Power Cords
      Power Distribution Units
      Power Generation Systems
      Power Ready Notebook Cases
      PowerChute Business Edition
      PowerChute Inventory Manager
      PowerChute Network Shutdown
      PowerChute Personal Edition
      PowerChute plus
      PowerManager
      PowerShield
      Preventive Maintenance
      Project Management Services
      ProtectNet
      Rack Air Distribution
      Rack Components
      Rack LCD Consoles
      Rack PDU Accessories
      Rack-mount Transfer Switches
      Refrigerant Distribution
      Remote Monitoring Services
      Replacement Batteries
      Replacement Notebook Batteries
      Residential Hardwire Surge Suppression
      Retail
      Retractable Cables
      Room Air Distribution
      Room Cooling Accessories
      Router Cables
      Row Cooling Accessories
      SCSI
      Security Cameras
      Sensors
      Serial
      Service Bypass Panel
      Service Plans
      Silcon
      Silcon Accessories
      Silcon Battery Systems
      SLM/FLM Series
      SmartSlot Expansion Chassis
      Smart-UPS
      Smart-UPS Accessories
      Smart-UPS Battery Systems
      Smart-UPS DP
      Smart-UPS On-Line
      Smart-UPS RT
      Smart-UPS VT
      Software Configuration
      Software Education
      Software for NetBotz Appliances
      Software Installation
      Software Integration
      Spare Part Kits
      Specialty Enclosures
      Start-Up Service
      Stationary Power Distribution Units
      Step-Down Transformer
      StruxureWare Central
      StruxureWare Operations Suite
      SurgeArrest Essential
      SurgeArrest Home/Office
      SurgeArrest Notebook
      SurgeArrest Performance
      Switch Boxes
      Switched Rack PDU
      Symmetra
      Symmetra Accessories
      Symmetra Battery Systems
      Symmetra MW
      Symmetra MW Accessories
      Symmetra Power Module
      Symmetra PX
      Symmetra PX Accessories
      Sync and Charge Cables
      Thermal Containment
      Thick and Thin Ethernet
      Token Ring
      Toploading Cases
      Traditional Cases
      Training Services
      Transceivers
      Transportation
      Travel Mice
      TSP Accessories
      TSP Battery
      TSP/Generator
      TSP/Total System Power
      Tune-UPS for Symmetra
      Uniflair Chilled Water
      Universal Mobile Device Batteries
      Universal Notebook Batteries
      Universal Notebook Power Adapter
      Universal Power Accessories
      Universal Power Adapters
      UPS Network Hub Card
      UPS Network Management Cards
      USB Adapters & Converters
      USB Cables
      USB Charging Cables
      USB Hubs
      Wall-mount Transfer Switches
      Wheeled Cases
      Wireless
      Wizards and Configurators
      WS200