clamp band flex cond 25mm

Flexible Conduit Terminators, Clamp Bands, 25mm

Catalogue Number: 267/25
clamp band flex cond 25mm
Colour: Black
Colour: Per UOM Std.
  • Black 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Sustainable offer status
Green Premium product
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
ENVPEP100802EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Is part number 260/25 available in Orange?

No. Unfortunately, the 260/25 is only available in Grey.

What is the standard pack size of the 262/25?

The standard pack size of the 262/25 is 50

Some of the key features are:
  • Rigid Tube
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=262/25
 

What are the part numbers for the 25mm PVC saddles and spacers?

The part numbers are 261/25 for the saddles and 261S25 for the spacers. 

Some of the key features are:
  • 63mm Length x 20mm Width x 29mm Overall Height
  • 48mm Mounting Centre
For further information please visit https://www.clipsal.com/Trade/search-results?q=261/25



 

What is the part number for 238A with 25mm spout?

The 238/25 has 1 x 25 mm spout & 2 x25 mm conduit entries.

Are the Clipsal Conduit Clips available in Electric Orange?

No, they are only available in grey.

This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

What is the height of a 261E25?

The 261E25 has a height of 18mm.
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=261E25

What is the part number for a surface mount enclosure to suit 319HP Pneumatic timer?

238/25 is a surface mount enclosure with 25mm end entries that will suit 319HP.

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238/25

What are the part numbers of slip type expansion couplings?

Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
16mm = 251/16
20mm = 251/20 *
25mm = 251/25 *
32mm = 251/32
40mm = 251/40 *
* = only available in Grey
Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
Dimension details are attached.
 

What are the dimensions for a 261S Saddle Spacer?

The dimensions for a 261S Saddle Spacer are 261S are:
 
Saddle Spacers
Catalogue Number Size Length (L) Width (W) Centres (CRS.) Standoff (T) Height (H)
261S16 16mm 55mm 21mm 32mm 8mm 14mm
261S20 20mm 61mm 22mm 40mm 8mm 14mm
261S25 25mm 74mm 26mm 48mm 8mm 14mm

Saddles Spacers set a conduit run off the wall 8mm to allow easier cleaning and repainting and to facilitate entry into equipment. They are available in sizes 16mm through 25mm.
Standard colour is Grey (GY), with Orange (EO) also available at extra cost.

For further information please visit www.clipsal.com/Trade/search-results?q=261S


 

What is the part number for the Relay and RPO connector for the Conext CL inverters?

One set of dry contact Relay and RPO connectors are provided along with the wiring box packaging.
The Relay and RPO connector is included in a plastic bag with other connectors, if it is lost, you will have to purchase another one.
The part number is 0J-0L2344 (Lit Kit IEC CL 20/25 kw Rohs package)

How to calculate Energy readings from the raw Integer register data on an Energy Meter

Issue
The energy values are stored across two 16-bit integer registers on an energy meter. 

Product Line
Energy Meter

Environment
Reading and converting Modbus register values

Resolution
The Energy Meter stores energy across two 16-bit integer registers.

Register #1 and Register #2 (Modbus address 257/258 for Register #1 and 259/260 for Register #2). Register #2 is the High WORD and Register #1 is the Low WORD. 

The Multiplier/Divisor table states that both of these registers must be divided by 32 to obtain the real value from the raw data.
The Multiplier/Divisor should NOT be applied to both registers. It is applied to the final value of both registers.

To calculate the Energy the registers must first be arranged as the register list states [2] is the High word and [1] is the Low word.

To make [2] the High word it needs to be shifted to the left 16 bits.
To accomplish this multiply the value in [2] by 65,356.
You will then add this value to the value in [1].
The final value will be divided or multiplied by the correct scaling value. Please see the example listed below.

For this example we will assume an Energy Meter with 300 amp CTs. According to the Integer Multiplier/ Divisor table, 300 amp CTs will give a divisor value, (d), of 32 and a multiplier value, (m), of 0.03125.
We will assume the following register values.
Register #1 = 29,586
Register #2 = 31

Using Divisor Table
kWh = ([R2]*65,536+[R1])/d
kWh = (31*65,536+29,586) / 32
kWh = 64412.56

Using Multiplier Table
kWh = ([R2]*65,536+[R1]) * m
kWh = (31*65,536+29,586) * 0.03125
kWh = 64412.56

*Note the divisor will not always be 32 and the multiplier will not always be 0.03125. For the correct values please see the Integer Multiplier Table.