end cap conduit 16mm

SoLid Fittings - PVC, Conduit Caps, 16mm

Catalogue Number: 262/16
end cap conduit 16mm
Colour: Grey
Colour: Per UOM Std.
  • Grey 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series 262
Material
PVC (polyvinyl chloride)
Diameter
  • inner: 16 mm
  • outside: 20 mm
    • Length
      20 mm
      Sustainable offer status
      Green Premium product
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP100802EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      How many 261/16 Clipsal saddles are there in a carton?

      There are 50 16mm saddles in a carton.

      Note: This information can be found in your Clipsal pocketbook right next to the part code.

      Are the Clipsal Conduit Clips available in Electric Orange?

      No, they are only available in grey.

      This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

      Are the 265 series insulated boxes (suitable for numerous junctions and terminations) IP rated?

      The 265 series is a range of IP56 rated insulated boxes suitable for numerous junctions and terminations. Each box is supplied with a 3mm sealing gasket.

      This applies to the 265/1, 265/3, 265/4, 265/5, 265/7 and 265/7D.

      What is the standard pack size of the 262/25?

      The standard pack size of the 262/25 is 50

      Some of the key features are:
      • Rigid Tube
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=262/25
       

      Is the junction box 265/1 UV rated?

      No it doesn't have a rating as such, however it is UV resistant.

      What screws would suit a 265/1-GY.

      The part number for the screws would be 265SCREW.

      Does the 252/32/2A come in orange?

      No, the 252/32/2A only comes in grey.

      With an ATV212, is there a auto/ manual configuration to switch between PID reference and a second analog reference?

      [Auto/man speed ref] Auto/Manual Speed Reference Switching 0
      0 [Enable]
      1  [Disable]
      Switching between two speed reference sources by means of a logic input is enabled if parameter F200 is set to 0.
      To use this function, you need to assign a logic input to function 38, Auto/Man speed ref.
      When the assigned logic input is off, the drive will follow the speed reference source defined by parameter [Frequency mode sel]
      (FMOd)
      When the assigned logic input is on, the drive will follow the speed reference source defined by parameter [Remote spd ref 2]
      (F207)
      When parameter F200 is set to 1, the drive will follow the FMOd speed reference source when it is operating above 1 Hz.
      Below 1 Hz, it will follow the F207 speed reference source



      CTA-ID : 2062816

      Do you do the 265/1 in a orange colour?

      Yes, we can offer the 265/1 in electric orange. The part number is 265/1-EO.
      Some of the key features are:
      • Surface mount
      • Dimension: 77 mm Length x 77 mm Width x 54 mm Height
      • 63.5 mm screw centres C, 63.5 mm screw centres D
      • Weatherproof, full cover plate
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=265/1


       

      What are the dimensions for a 261S Saddle Spacer?

      The dimensions for a 261S Saddle Spacer are 261S are:
       
      Saddle Spacers
      Catalogue Number Size Length (L) Width (W) Centres (CRS.) Standoff (T) Height (H)
      261S16 16mm 55mm 21mm 32mm 8mm 14mm
      261S20 20mm 61mm 22mm 40mm 8mm 14mm
      261S25 25mm 74mm 26mm 48mm 8mm 14mm

      Saddles Spacers set a conduit run off the wall 8mm to allow easier cleaning and repainting and to facilitate entry into equipment. They are available in sizes 16mm through 25mm.
      Standard colour is Grey (GY), with Orange (EO) also available at extra cost.

      For further information please visit www.clipsal.com/Trade/search-results?q=261S


       

      Is there an alternative for SS165/15/2?

      There is no direct replacement for the SS165/15/2
      The closest product to the SS165/5/2 is the 362 and 363 series of surface switches

      For more information please visit the Clipsal web site on the links provided .
      https://www.clipsal.com/Trade/search-results?q=362
      https://www.clipsal.com/Trade/search-results?q=363

      What are the processes associated with PowerSCADA Expert?

      Issue
      The processes associated with PowerSCADA Expert.

      Product Line
      PowerSCADA Operations, PSO
      PowerSCADA Expert, PSE
      PowerLogic SCADA, PLS

      Environment
      Runtime Manager
      Task Manager

      Cause
      In cases that a project does not start or shut down properly, it is advised to check the processes.  In the case the project did not shut down properly, the process can be killed manually using Windows Task Manager.  This way upon a restart of Runtime Manager, the project starts without any problem.

      As such it is important to know the associated processes.

      Resolution
      The example below shows a project with six I/O Servers (numbered 2, 4, 6, 8, 10 and 12), a Trend Server, one Alarm Server and a Client (represents the main project); a total of 9 processes as shown in Runtime Manager.

      NOTE: While the screenshot below applies to older version of SCADA, the same analogy applies to newer versions.

                

      The processes above can be verified in Windows Task Manager as shown below.  There is an entry for each of the above 9 processes, each labeled Citect32.exe *32.  Note the one-to-one correspondence among the Process IDs in Task Manager and Process IDs in Runtime Manager.  For example PID 22716 in Task Manager corresponds to IOServer6 as show in the above picture.

                


      NOTE: The last three processes in the above screenshot applies to PSE 8.1 and older; more explanation below.

      In case SCADA application is open for editing a project, there will be additional processes.  Process names and their corresponding application are shown below.  Depending on the version, different applications open.

      1. SCADA version 8.1 and older:

      CtDraw32.exe *32     Citect Graphics Builder
      CtEdit32.exe *32       Citect Project Editor
      CtExplor.exe *32       Citect Explorer

      2. SCADA version 8.2:

      PowerSCADA Studio (32 bit)     PowerSCADA Studio

                



      Example of a PowerSCADA 8.2 project with 5 process and PowerSCADA Studio open for editing:

      1. Runtime Manager:

                

      2. Task Manager (Details tab):