sock swt twin 10a 250v e/sw

Twin Switch Socket Outlet, 250V, 10A, Standard Size, Extra One Way Switch

Catalogue Number: 25X
sock swt twin 10a 250v e/sw
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Cream 1 PCE
  • Dark Blue 1 PCE
  • Red 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
2 gangs
Pin number
3
Number of power socket outlets
2
Actuator
  • switch
  • rocker
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      PC (polycarbonate)
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      16 mm
      Length
      115 mm
      Width
      73 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN
        Circularity Profile
        N/A

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • CAD Files and Packs

        • Technical Data Catalogues

        • Installation Instruction

        • Product Environmental

        • Specifications

        • Case Studies

        • Certificates (MSDS)

        Frequently Asked Questions

        hide show

        What is the power supply to suit the 560125R/2 25W audio amplifier?

        The power supply to suit the 560125R/2 25W audio amplifier is a 5600P24H3750A.

        What does the suffix 25K indicate on an MPZ device?

        Issue:
        What does the suffix 25K indicate on an MPZ device?

        Product Line:
        Mini power zone

        Environment:
        MPZ mini power zone

        Cause:
        Product features

        Resolution:
        The 25K suffix indicates the MPZ is rated at 25KAIC. The standard AIC is 18K. The 25K units have a higher rated 25K AIC primary main breaker installed, and so the entire unit AIC is then rated at 25K. Same for the 65K.

        Is the extra switch in the 15X removable?

        Yes, the extra switch in the 15X is removable. Any 230v rated 30 series mec will fit in it's place.

         

        Can a 751 be used with 25W LED?

        Yes, it can but you will need to put a 31CAP in parallel with the load.

         

        Will 30USBCM fit into 25XD socket outlet

        Yes the 30USBCM will fit into 25XD.

        For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=25XD
         

        What are the dimensions for a 4FCC10?

        286 MM Width, 258 MM height and 100 MM + wall thickness depth 

        What is the part number for the flap of 255 as a spare?

        The part number for the flap of 255 as a spare is 255FLAP-TR.

        What is the max distance for the Wireless (Harmony) pushbuttons without a relay antenna

         The maximum distance is 100m without obstructions, this is reduced to 25m if the receiver is enclosed in a metal enclosure.

        What is the part number for a 25A 3 phase D curve breaker?

        The part name is A9F55325

        Can the Com'X Series have a Publication Time smaller than an hour?

        Unfortunately it is not possible to have a publication time for less than an hour for either the Com'X 5xx or Com'X 2xx series units.

         

        What is a 2pole 25A 56 Series isolator for a dock

        Part number is PDL 56SW332

        What is the DC22A rating for the PDL 56SW432KG

        25A @ 115V

        Is there a 40A version SPN N Vigi RCBO

         No - 25A is the largest

        What is the part code for a slim RCBO 25A

         The part code is 19586

        What is the part number for 4 pole ,C Curve, 10KA, 25A breaker?

        The part number for 4 pole , C curve, 10KA, 25A breaker is A9F54425

        A9F54425
        Acti9 iC60H 4P 25A C Miniature Circuit breaker
        For more information see:
        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F54425
         

        What is the interrupt rating of the obsolete KAL36250?

        Product Line:
        Legacy Circuit Breakers

        Environment:
        Electrical Distribution Equipment

        Resolution:
        The interrupt ratings below:

        42k AIR at 240V
        25k AIR at 480V
        22k AIR at 600V.  
         

        Do you have a double pole outlet with USB mechanism?

        No. However, you can assemble one yourself using a 25XD and a 30USBCM.

         

        What is the part number for flap to suit 255?

        The part number for flap to suit 255 is 255FLAP-TR.

        Does a 2025RCD30-WE fit into a 255 weather protected box?

        Yes, the 2025RCD30-WE will fit into a 255 weather protected box.The 2025RCD30-WE is 27mm deep and the 255 has 35mm depth. The bottom screwed plug will need to be shortened if not used as a cable entry.

        Is part no 255 available in shallow version

        There is not a shallow version of part no 255 available

        for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=255


        User-added image

        Is the 25, Standard Series, double outlet,10A available in the colour Blue?

        Yes, the 25, Standard Series, double outlet,10A is available in the colour Blue. The part number is 25-DB.

        Vamp 255 communications maps

        Issue    
        Need the register list for my VAMP relay.

        Product Line
        Vamp 255

        Resolution
        See the attached files for the VAMP 255 communications maps, this includes maps for:
        Modbus
        Profibus
        SPA bus
        DNP3
        IEC101
        IEC103
        Modbus Master
        ProfibusDP

        Note:  Latest information is available in m.vamp.fi

        On a LC1D25 contactor , are the aux contacts rated at 25A

        The aux contacts on all our contactors are rated at 10A Ith

        Is there a 32A version of an SPN N Vigi

         No - the highest current rating is 25A

        What is the complete part number for a 25A 11Kw 3P Contactor with 24VDC coil?

        LC1D25BD is the correct part number

        "ISX Central's Internal Browser ""Home"" button doesn't work with 2.x NMC Firmware"

        Issue:

        ISX Central's Internal Browser ""Home"" button doesn't work with 2.x NMC Firmware

        Product Line:

        InfraStruxure Central / Struxureware Data Center Expert.

        Environment:

        InfraStruxure Central / Struxureware Data Center Expert
        Any version 2.x firmware on APC SNMP enabled devices.

        Cause:

        Any APC device running older 2.x firmware reacts differently due to coding differences.

        Resolution:

        There is no plan to update this feature at this time to work with the older devices.

        Will Zen switch plate fit in 223H and 255 enclosures?

        Yes, Zen switch plates will fit in 255 as it has a depth of 77mm. It will not fit in 233H as it has a depth of 29mm only.

        For further information, please visit 
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=223H

        https://www.clipsal.com/Trade/Products/ProductDetail?catno=255

         

        Do you have flexible cover for underground cables that is 150mm wide?

        Yes, we have 25m rolls of cable cover. The part number is 287R150HD.

        Some of the key features are:
        •  AS4702 and AS/NZS3000, DR94102 and AS1462.3.
        For further information please visit https://www.clipsal.com/Trade/search-results?q=287R150HD

        What does the "H" at the end of the Modicon M340 part number mean?

        The "H" at the end of the Modicon M340 part number stands for the "Ruggedized" version. This version allows the M340 to be used in more severe environments because of the protective coating on all their circuit boards and has an extended temperature range from - 25C to + 70C.

        Legacy KB System (APS) Data: RESL209489 V1.0, Originally authored by DiSa on 10/25/2012, Last Edited by DiSa on 10/25/2012
        Related ranges: Modicon M340

        Whats the part number for a Din rail mount 25A change over switch?

        The part number for a Din rail mount 25A change over switch is a 4PS25CO

        • Maximum 4 - Isolators - DIN rail mount
        • Night, off, day switching of luminaries where daylight supplements internal lighting
        • Incoming and outgoing terminals are screw down type and accommodate copper conductors up to 16 sq mm
        • Auto, off, manual switching of machines
        • Auxiliary, off, mains switching of small stand-by generators
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4PS25CO

        What is the timing range for a 2031VETR-WE?

        The timing range for a 2031VETR-WE is 15 seconds to 254 minutes.
        Please see following link for complete range
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3

        What is the operating voltage for the Vamp 255 digital inputs?

        Issue: Need to know the operating voltage of the Vamp 255 digital inputs.

        Product Line: Vamp 255

        Resolution: The Vamp 255 has 2 sets of digital inputs. Digital inputs 1-6 are internally wetted with 48Vdc. The other 12 digital inputs operating voltage is defined by the part number ordering code:
        A = 40 - 265 VAC/VDC
        B = 18 - 36 VDC
        C = 40 - 265 VAC/VDC + ARC Protection
        D =  18 - 36 VDC + ARC Protection
        E = 40 - 265 VAC/VDC + D19, DI20 + ARC channel
        F = 18 - 36 VDC + D19, DI20 + ARC channel

        Keywords: Vamp 255, Vamp 255 digital inputs, Vamp 255 operating voltage

        Should the EGX300 stop logging a device after an error occurs?

        Issue
        An EGX continues to log a device despite the User Guide suggesting it should stop after a missed interval.

        Product Line
        EGX300 Gateway Device

        Environment
        EGX Data Log

        Resolution
        The table containing 'Error Codes for Data Logs' in the User Guide (pg. 39) states "Logging is left enabled unless the last interval was missed" for error codes 19 and 25. This suggests that the EGX should stop logging data from a device after an error appears. However, as seen in the image below, an error is observed more than once and the device continues to be logged.



        Since the EGX300 is an obsolete device, it is unlikely the User Guide will be updated. This article will serve as a correction for the EGX300 User Guide's wording.

        what is the KA rating 4rcbm232/30.

        For this 4RCBM series  range the KA rating is above 25a is limited to 6KA and below 25amps is 10ka.

        what is new code for Merlin Gerin 15960 CT Contactor ?

        new code = A9C20736  iCT Contactor 25A 2NC AC7a rated 
         

        What are the codes for the Fault Arc Detection Devices?

        6A - A9FDB606
        10A - A9FDB610
        16A - A9FDB616
        20A - A9FDB620
        25A - A9FDB625

        What is the explanation of the Parameter FLC1 in TeSys T.

        FLC1 is the parameter to enter the Motor nominal current in TeSys T. In this parameter, the Motor nominal current is entered as a percentage of the rated value of the TeSys T. 

        Example:
         
        For TeSys T of range 8Amps (LTMR08) and a motor of 2 Amps nominal current, you have to set the FLC1 value to 25% because the Motor nominal current is 25% of the full load current of TeSys T Module (LTMR08).
         
        This means that the current in register 466 (value of current in percent) take the value of 100% when you reach 25% of the current of the TeSys T Module rated current value.

        Looking for a stainless steel enclosure dimensions 500 x 500 x 250

         Options are NSY3X6625 - 600 x 600 x 250 or NSY3X7525 - 700 x 500 x 250

        What is the alternate to part number 4EL25/2/30, 25A , 30mA, 2 module RCD?

        4RC225/30 is an alternate for 4EL25/2/30, 25A , 30mA, 2 module RCD.

        Key Features

        • Unique new white finish for a fresh modern look
        • Base module = 18 mm wide, compact standardised and consistent module dimensions
        • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
        • Cable automatically guided to the correct position: terminals with guard
        • Fast closure
        • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
        • Same housing as AC type MCBs. Uniformity in space requirements and installation
        • Superior, safe and reliable DC breaking per pole
        • Used with marine, telecommunications, solar power, emergency power, battery power
        • Excellent breaking capability for its compact size
        • Standard type
        • 75 mm modular spacing
        • Surge current protected to 250 A at 8/20 uS
        • Operating temperature: -5 to 40 deg C
        • Degree of pollution is 2
        • Rated Impulse withstand voltage is 6 kV

        https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC225/30

        What is the part number for the 3 Pole 250 Amps 25kA MCCB?

        The part number for the 3 Pole 250 Amps 25kA MCCB is "LV431110"

        https://www.schneider-electric.com.au/en/search/LV431110

        What is a 'BMXNOE0100.2' ?

        The BMXNOE0100.2 indicates a BMXNOE0100 with firmware version 2.x or higher.


        Legacy KB System (APS) Data: RESL212295 V1.0, Originally authored by DaSo on 08/13/2013, Last Edited by DaSo on 08/13/2013
        Related ranges: Modicon M340

        Tenant Metering Software Commercial Edition (TMSCE) Documentation

        Issue
        TMSCE documentation.

        Product Line
        TMSCE 2.x

        Environment
        TMSCE Manuals: Installation guide, User Guide.

        Resolution
        The documents for the TMSCE 2.x software are attached. 

        Can the memory of a M221 logic controller be expanded?

        The memory of M221 cannot be expanded. The M221 has the following types of memory:

        RAM: 512 Kbyte, of which 256 Kbyte available for the application. It is used to execute the application and contains data

        Flash: 1.5 Mbyte, of which 256 Kbyte is used to backup the user application and data in case of power outage. It is used to save the application

        The SD card is only used to transfer the application or update the firmware

        What is the cut out size for a B10/30/5 switch plate?

        The cut out size for the wall box to suit the B10/30/5 is 232mm x 97mm x 58mm.

        Some of the key features are:
        • 30 series rocker type
        • B-Style
        • Switch arrangement 5 horizontal and 2 vertical
        • Fascia size: 257 mm Width x 120 mm Height

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=B10/30/5

        Can you get the flap / lid only for the 255 weatherproof enclosure?

        Yes, the part number for the flap / lid is 255FLAP-TR

        What is part number for lid to suit 255?

        Part number is actually 255FLAP -TR

        ETSNZ - How can we use the M221 to read UINT32 and FLOAT32 data types out of a Power meter PM5300?

        Symptoms:
        • If you use the READ_VAR at address 130 with quantity = 1 you will get an error : CommError = 254 and OperError = 3.
        • If you change the quantity = 2 you will still get the same error : CommError = 254 and OperError = 3: You will get the high order byte in %MW130 = 0 and lower order byte in %MW131 = 0.
        The general register list for the Power meters gives you the Jbus addressing registers and not the Modbus addressing registers.
        Jbus addressing starts a n and the Modbus addressing then should be n -1.
        • If you now use the READ_VAR at address 129 (n -1) with quantity = 1 you will get the same error : CommError = 254 and OperError = 3.
        • If you change the quantity = 2 life is good: You will get the high order byte in %MW130 = xxxx and lower order byte in %MW131 = xxx.

        Do you have a metal plug for the WMC532?

        The metal plug that suits the WMC532 is the P532.

        Some of the key features are:
        • 5 round pin-with plastic screw ring
        • Dimension 258 mm Height x 115 mm Width x 120 mm Depth

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P532
         


         

        What are the minimum operating system requirements to run the M340 UnityLoader version 10 software?

        System: Pentium processor 500 MHz or higher
        RAM memory: 256 MB
        Hard disk space: 25 MB including the memory space for the software installation, temporary space for execution.
        Operating System: Windows 7 or higher


        What are the part numbers for the Power and Feedback cables for a BMH1003 xxxxxx motor ?

        Issue: Part numbers

        Product Line: BMH

        Environment: None

        Cause:

        Resolution:

        The part number for the power cable for a BMH1003 xxxxxx motor is VW3 M5101 Rxxx . where xxx = 15, 30, 50, 100, 150, 200, 250, 500, 750 for cable lengths 1.5m, 3m, 5m, 10m, 15m, 20m 25m 50m and 75 m respectively, The composition of this cable is [(4 x 1.5 mm^2) + (2 x 1 mm^2)] and comes with a pre-made M23 style industrial connector on the motor end and free ends on the drive side.

        The part number for the feedback cable for a BMH1003 xxxxxx motor is VW3 M8102 Rxxx  where xxx = 15, 30, 50, 100, 150, 200, 250, 500, 750 for cable lengths 1.5m, 3m, 5m, 10m, 15m, 20m 25m 50m and 75 m respectively, The composition of this cable is [(3 x 2 x 0.14 mm^2) + (2 x 0.34 mm^2)] and comes with a pre-made M23 style industrial connector on the motor end and an RJ45 style connector on the drive side.
        Show More