box wall pvc 2 gang deep

WAll Boxes - Plastic, Moulded Plastic WAll Box 2 Gang - Deep Type

Catalogue Number: 257D2
box wall pvc 2 gang deep
Colour: Grey
Colour: Per UOM Std.
  • Grey 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Shape
rectangular
Number of gangs
2 gangs
Material
plastic
Length
102 mm
Width
96 mm
Depth
60 mm
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the part number for a 10A 6kA 1p MCB

 The part code is 25802

What is the replacement for 25736 MCB?

The replacement for 25736 MCB is A9F55363

A9F55363 
Acti9 iC60H 3P 63A D Miniature Circuit Breaker

 

What is the wall box for a P2033/2VA-WE

 Part code 157/2

What is the terminal size for the 847 series?

Up to 25mm2

What is the wallbox to suit the 4025H2?

The part name is as follows: 2157H2

What are the dimensions for wall boxes , 2157/2 and 2157/3?

Dimensions are :
2157/2 -  L136mm x W98mm x  D58mm
2157/3 -  L207mm x W98mm x  D58mm
For further information , visit links below:
https://www.clipsal.com/Trade/search-results?q=2157/2
https://www.clipsal.com/Trade/search-results?q=2157/3
User-added image
 

What is the part code 2 AMP MCB 6kA + fault auxiliary

 You will need a 25798 +26927

What is alternative for Schneider part number 25730?

The part number A9F55320 replaces 25730.

new codes for 25642 and 256741

25642
A9F54104

 
25674
A9F54320 

What is the flush box to suit the Clipsal 4025H2-OM ?

Use a Clipsal 2157H2

What is the dimensions for a Clipsal PT80-BK

 Dimension 60 x 52 x 30 and takes up to 25mm2 cables

L1JCN - What is the code for the flush box to suit 31/2VX-WE

157/2 wall box 2gang

Is the extra switch removable on 25XD, twin socket outlet?

Yes, the extra switch on 25XD is a removable double pole extra switch. 25XD is Twin Switched Socket Outlet, 250V/10A, double pole and dimensions are 115mm(L) x 73mm(W) x 16mm(D). Mounting centers are 84mm apart.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=25XD

 

What is the flush box to suit the Clipsal 4025H2-OM ?

Use a Clipsal 2157H2

What is the flush box to suit the P2025/2?

Standard 2 gang flush box will suit -  part number 157/2

Is the 25, Standard Series, double outlet,10A available in the colour Blue?

Yes, the 25, Standard Series, double outlet,10A is available in the colour Blue. The part number is 25-DB.

What are the part names for the mounting equipment for the Saturn 4025H2?

Wall clip - 2154H2
Wall Bracket - 2155PHRM2
Wall Box - 2157H2

What is wall box to suit Saturn Zen part no Z4025H2

The 2157H2 is used on both standard Saturn & Saturn Zen

What mounting options can be used with 4025H2 or Z4025H2 ?

Use a 2154H2 ( wall clip) , 2155PHRM2 ( plaster mount bracket ) or 2157H2 ( Wall box) recessed 8mm
for more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=4025h2

What bracket is used to suit the larger Prestige range.

The bracket would be the 156/2.
This is also available in a wall box version as a157/2.
Please see below documentation for more information.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=156/2

Can you use two flush boxes behind a Saturn quad socket?

Yes you can it has 2x84mm mounting centers. Or you can use the 2154H2 mounting bracket or the 2157H2 Metal wall box.

What are the hole sizes in the BP165/7?

The hole sizes in the BP165/7 are as follows:
Dimensions: 100 x 43 x 40mm.
Terminal bar: 16 x 16 x 76mm.

2 tunnels: 9.5mm diameter accommodate 50mm2 cables.
1 tunnel: 8.0mm diameter accommodates 35mm2 cable.
2 tunnels: 7.1mm diameter accommodate 25mm2 cables.
2 tunnels: 5.5mm diameter accommodate 16mm2 cables.

Mounting centres: 71 x 29mm.

Why does my Network Management Card report warmstart/coldstart or network interface restart/coldstart?



Issue

My UPS Network Management Card or Network Management Card enabled product is reporting one or more of the following alarms: System: Warmstart, System: Coldstart, System: Network Interface restarted, System: Network Interface Coldstarted.


Product Lines
 
  • Web/SNMP Card - AP9606
    Devices with an embedded Web/SNMP Card include (but are not limited to): Environmental Monitoring Unit 1 (AP9312TH)
     
  • Network Management Card 1 (NMC1) - AP9617, AP9618, AP9619
    Devices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP78XX, AP79XX), Rack Automatic Transfer Switches (AP77XX, Environmental Monitoring Units (AP9320, AP9340, NetBotz 200)
     
  • Network Management Card 2 (NMC2) - AP9630/AP9631CH, AP9631/AP9631CH, AP9635/AP9635CH
    Devices with an embedded Network Management Card 2 include (but are not limited to): 2G Metered/Switched Rack PDUs (AP84XX, AP86XX, AP88XX, AP89XX), Rack Automatic Transfer Switches (AP44XX), Certain Audio/Video Network Management Enabled products, Smart-UPS Online (SRT).

 
Environment
  • All serial numbers
  • All firmware versions

     
Note: As of APC Operating System (AOS) v5.1.5 or higher, the critical alerts of System: Warmstart or System: Coldstart have now been renamed to an Informational alert of System: Network Interface restarted or System: Network Interface coldstarted, respectively.


Cause


A System Coldstart event indicates that the NMC (Network Management Card) has just been powered and has completed startup.
  • Power interruption to the NMC - If a device powering the NMC suffers an interruption of power, the NMC will restart when power is reapplied to that device.

A System Warmstart (or restart) event indicates that the NMC has rebooted and completed startup, without losing power. This may be due to any of the conditions mentioned below.
  • The default gateway is wrong or the network traffic is too heavy and the gateway can not be reached.
The default gateway can be any valid node's IP on the network management card's network. The Management Card implements internal watchdog mechanisms to protect itself from becoming inaccessible over the network. For example, if the Management Card does not receive any network traffic for 9.5 minutes (either direct traffic, such as SNMP,or broadcast traffic, such as an Address Resolution Protocol [ARP] request), it assumes that there is a problem with its network interface and restarts to prevent further problems. To ensure that the Management Card does not restart if the network is quiet for 9.5 minutes, the Management Card attempts to contact the default gateway every 4.5 minutes. If the gateway is present, it responds to the Management Card, and that response restarts the 9.5-minute timer. If your application does not require or have a gateway, specify the IP address of a computer that is running on the network most of the time and is on the same subnet. The network traffic of that computer will restart the 9.5-minute timer frequently enough to prevent the Management Card from restarting.  
  • FTP upload completion - After a new AOS or Application firmware upgrade has been uploaded to the NMC the NMC will automatically reboot and run the new firmware.
  • Logout if settings are changed - Modification of some NMC settings will require a reboot of the NMC.
  • Reset Switch - If the Reset button on the front panel of the NMC is pressed the NMC will reboot immediately.
  • Web Interface Reboot request - One of the NMC options for Reboot was selected in the Web User Interface.
  • Network settings have changed - At least one of the TCP/IP settings changed. The system will need to reboot for the settings to take effect.
  • Restart SNMP Agent (SNMP v1 or v3) - A request to restart the current SNMP agent service was received. Majority of SNMP configuration changes will require an SNMP agent service restart to apply the change.
  • Load and Execute SNMP Agent Service (SNMP v1 or v3) - An internal request to load and execute a new SNMP agent service was received. Enabling or disabling SNMP v1 or v3 will require a restart to apply the change.
  • Clear Network and Start SNMP Agent (SNMP v1 or v3) - A request to clear the NMC's network settings and restart the SNMP agent service was received.
  • Smart-UPS Output Voltage Change - Some Smart-UPS models allow the output voltage to be changed. This requires a reboot of the NMC firmware.
     
  • Remote Monitoring Service (RMS) communication has been lost (NMC2 only) - If for a certain period of time, RMS communication is lost, you may see several System: RMS failed to communicate with the server events followed by a Warmstart/Network Interface Restart message in the NMC2 event log. This is normal and the NMC2 reboots in this situation as a failsafe mechanism in case the communication problem is internal to the NMC2. On NMC2, it may be helpful to obtain the debug.txt or dump.txt file from the card's file system in the /dbg folder to help validate, if the files are present.
  • Detected Firmware Error - An internal firmware error was detected by the NMC and to clear the error, the NMC firmware explicitly reboots itself as a failsafe. On NMC2, it may be helpful to obtain the debug.txt or dump.txt file from the card's file system in the /dbg folder to help validate, if the files are present.
  • Unrecoverable Firmware Error - An undetected firmware error occurred and the hardware watchdog reboots the NMC to clear the error. On NMC2, it may be helpful to obtain the debug.txt or dump.txt file from the card's file system in the /dbg folder to help validate, if the files are present.

 
Resolution
 
It is recommended to follow the instructions in article FA156131 and download all available event logs for your product. This includes event.txt, data.txt, and config.ini for NMC1 and NMC2 as well as debug.txt and dump.txt for NMC2 only.

For NMC1:
 
  • Review the event.txt file to see if any of the causes listed above could be why your Network Management Card has restarted or coldstarted.
  • Is this affecting more than one Network Management Card in your environment? This may point to a network traffic issue (too much, to little, or "bad" packets)  causing the Management Card to reboot due to the watchdog mechanism outlined above.
  • Note the frequency of the events in question. Can you pinpoint it to a certain time/certain set of events before and after?
    • If the warmstarts/network interface restarts are always the same amount of time apart, this may relate to a network traffic issue as well.
  • Depending on what you find, try rebooting your card's interface or resetting the card to defaults (after backing up your configuration). See if the issue persists.
  • Please contact APC support at any time for additional options and help to obtain a root cause for a warmstart/restart/coldstart. Also note these types of events don't always necessarily indicate a problem and only affect the Network Management Card's interface. Your UPS or device load is unaffected. Please have your log files (event.txt, data.txt, config.ini) available for tech support to review.
 
 
For NMC2:
  • Review the event.txt file to see if any of the causes listed above is why your Network Management Card has restarted or coldstarted. 
  • Is this affecting more than one Network Management Card in your environment? This may point to a network traffic issue (too much, to little, or "bad" packets) causing the Management Card to reboot due to the watchdog mechanism outlined above.
  • Note the frequency of the events in question. Can you pinpoint it to a certain time/certain set of events before and after?
    • If the warmstarts/network interface restarts are always the same amount of time apart, this may relate to a network traffic issue as well.
  • Depending on what you find, consider rebooting your card's interface or resetting the card to defaults (only after backing up your configuration and obtaining the aforementioned log files). See if the issue persists.
  • Please contact contact APC support for additional options and help to obtain a root cause for a warmstart/restart/coldstart. Also note these types of events don't always necessarily indicate a problem and only affect the Network Management Card's interface. Your UPS or device load is unaffected. Please have your log files available for tech support to review - event.txt, debug.txt and dump.txt are most important as these files can easily debug the situation. These two files are not available on NMC1 products.
  

What is the difference between the iC60N and the iC60H Circuit Breakers?

The differences between the iC60N and iC60H series of circuit breakers is the iC60N has a breaking capacity of 6kA at 240/415V, C Curve in accordance with AS/NZS60898.1, where as the iC60H has a breaking capacity of 10kA at 240/415V B, C & D Curve in accordance with AS/NZS60898.1.

In Australia the iC60N is only available in C Curve where as the iC60H is available in B, C & D Curve.
 
iC60N & iC60H Dimensions

Connection: Tunnel terminals for the following cables
- up to 25A : 25mm2 stranded
- 32 to 63A : 35mm2 stranded

For further information please visit https://www.schneider-electric.com.au/en/product-subcategory/1605-acti-9-miniature-circuit-breakers---mcbs/


 

What is the replacement for the part number 25733?

The replacement for the part number 25733 is "A9F55340"

https://www.schneider-electric.com.au/en/search/A9F55340

What is the replacement for the 25729?

The replacement for part number 25729 is "A9F55316"

https://www.schneider-electric.com.au/en/search/A9f55316


 

What is the size of the fascia on the B10/30/5?

The Multi Gang Switch Assemblies (less mechanisms) - Metal Plate Range, 30 Series Rocker Type, Switch Plate 10 Gang, 2 rows of 5 ( B10/30/5) has facia dimensions of
257mm (W) X 120mm (H).
Some of the key features of the  B10/30/5 are:
  • 30 series rocker type
  • B-Style
  • Switch arrangement 5 horizontal and 2 vertical
  • Fascia size: 257 mm Width x 120 mm Height
  • 10 number of switch apertures


For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=B10/30/5