sck swt twin 15 /10a 250v

Twin Switch Socket Outlet, 250V, 10/15A, Standard Size

Catalogue Number: 25/1510
sck swt twin 15 /10a 250v
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
2 gangs
Pin number
3
Number of power socket outlets
2
Actuator
  • rocker
  • switch
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      PC (polycarbonate)
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
    • 10 A
    • 15 A
      • Depth
        16 mm
        Length
        115 mm
        Width
        73 mm
        Fixing center
        84 mm
        Standards
      • AS/NZS 3100
      • AS/NZS 3112
      • AS/NZS 3133
      • AS/NZS 3000:approval number S/1
        • Sustainable offer status
          Green Premium product
          EU RoHS Directive
          Compliant
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          Product out of China RoHS scope. Substance declaration for your information
          Environmental Disclosure
          ENVPEP120506EN

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • Technical Data Catalogues

          • Specifications

          Frequently Asked Questions

          hide show

          Does 25/1510 have two separate connection for each outlet?

          Yes this plate has a 15A and a 10A outlet and they are separately wired.
          For further information please follow link below
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=25/1510

          What is part number for double GPO 15&10amp?

          Part number 25/1510 with 15amp & 10amp sockets & switches.

          What is the length of the bell mouth 288/150


           The length is 290mm long.
          please see following website for catalogue information as well as Technical specifications
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=288/150

          What size Duct Entry does the 900RMB have?

          It has 2x 25x16mm entries (one at each end).

          In some documentation, the picture shows the XALD211H29, but the listing doesn`t have the H29.

          Issue:
          In some documentation, the  picture shows the XALD211H29, but the listing doesn`t have the H29.

          Product Line:
          Harmony Control Stations

          Environment:
          All Products

          Cause:
          Product Features

          Resolution:
          H29 is a country code for Great Britain. It would have a metric conduit entry. For a standard 1/2 inch conduit entry for US, order a XALD211.


          CTA-ID : 2001110

          Symmetra PX 250/500: What happens when EPO is activated?

          Issue:
          Symmetra PX 250/500; What does the EPO (Emergency Power Off) trip
           
          Product line:
          Symmetra PX 250/500
           
          Environment:
          All serial numbers
           
          Cause:
          What occurs when the EPO on a Symmetra PX 250/500 button is engaged?
           
          Resolution:
          When the EPO is activated, UPS output breaker Q2 and the battery breakers are tripped. The Power Modules (inverter) and if in Static Bypass operation will the UPS turn off

          Does the ATV28 unit have MOVs on the line side?

          Issue:Does the ATV28 unit have MOVs on the line side?
           
          Product Line: ATV28
           
          Environment: All
           
          Cause: N/A
           
          Resolution: No.


           

          Symmetra PX 250/500 Battery to Power Module Ratio

          Issue:
          Symmetra PX 250/500 Battery to Power Module Ratio

          Product line:
          Symmetra PX 250/500

          Environment:
          All Product models, all serial numbers

          Cause:
          Required battery to power module ratio for a Symmetra PX 250/500

          Resolution:

          Ratio between numbers of battery shelves and power modules (PM)

          Maximum recommended discharge level on the batteries used for Symmetra PX 250/500 is 3CA, where CA means the current (Amps) by which the battery is charged or discharged divided by its Amp-hour (Ah) rating.  The 250kW runtime ratio is 10 PMs to 16 battery shelves resulting in a ratio of 1.6 battery shelf per 1 PM. Need to always round up the number of shelves

          Results if ratio is not maintained

          In some situations, the Power Modules will attempt to draw power from the batteries and if the ratio is not observed, you will potentially clear fuses in the battery modules and (less likely, but it happened before) burn traces on the battery backplane boards due to the DC inrush current.

           

           

          Video: How do I Change Language & Regional settings on my Symmetra PX 250-500 UPS?

          Issue:
          How to Change Language, date format & temperature unit settings on the APC Symmetra™ PX 250/500 UPS.
           
          Product line:
          Symmetra PX 250-500
           
          Environment:
          All Product models, all serial numbers
           
          Cause:
          The display may be accidentally changed to an unwanted language.

          Resolution:

           

          Begin at the home screen of the UPS.  



          Press the wrench key at the lower left of the screen.
          Select Language settings



          The following screen will have the available list of languages. Select you desired language.



          Press the Finish to lock in change.

          How do I configure network settings on my Symmetra PX 250/500 UPS?

          Issue:
          Video: How to Configure network settings

          Product line:
          Symmetra PX 250-500

          Environment:
          All Product models, all serial numbers

          Cause:
          How do I Configure network settings  on my Symmetra PX 250-500 UPS

          Resolution:
          Begin at the home screen of the UPS
          Press the wrench key at the lower left of the screen
          Select Configuration then User configuration
          Enter the user password (apc by default)
          Select NMC settings
          Select Configure NMC Settings on the card you would like to configure.
          Ensure the ‘UPS configuration access’ is set to read or read/write for the card
          Make desired changes and Select Apply to save changes.

          See the following video tutorial:

          Video: How do I adjust Display settings on my Symmetra PX 250/500 UPS

          Issue:
          How to adjust Display settings            

          Product line:
          Symmetra PX 250/500

          Environment:
          All Product models, all serial numbers
           
          Resolution:



          How to adjust your display brightness, timeout, other display settings, or calibrate the touch screen, on your Symmetra PX 250-500 kVA UPS.
           
          Begin at the home screen of the UPS.  



          Press the wrench key at the lower left of the screen.
           
          Select Configuration then User Configuration



          Enter the User password (apc by default)



          Select 'Display Settings'

          What is the material of the cover for a 9013GHG2 made of?

          Issue:
          material of the cover for a 9013GHG2 made of

          Product Line: 
          Pressure, Vacuum, and Float Switches

          Environment:
          9013GHG2

          Resolution:
          Noryl SE-1X is used on 9013G devices for the cover, and on 9013F products with 3R rating.
          Show More