SWITCHED SOCKET TWIN STANDARD PTN 15A
socket swt twin std ptn 15a
SWITCHED SOCKET TWIN STANDARD PTN 15A
socket swt twin std ptn 15a

Twin Switch Socket Outlet, 250V, 15A, Standard Size

Catalogue Number: 25/15
SWITCHED SOCKET TWIN STANDARD PTN 15A
socket swt twin std ptn 15a
SWITCHED SOCKET TWIN STANDARD PTN 15A
socket swt twin std ptn 15a
Colour: White Electric
Colour: Per UOM Std.
  • Red 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
2 gangs
Pin number
3
Number of power socket outlets
2
Actuator
  • switch
  • rocker
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      PC (polycarbonate)
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      15 A
      Depth
      16 mm
      Length
      115 mm
      Width
      73 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • Specifications

        • Certificates (MSDS)

        Frequently Asked Questions

        hide show

        Does the Ritika Circuit breaker 25815 have the same dimensions as the 25823

         It has the same physical size

        What is a 2pole, 6A, C Curve, 6kA circuit breaker

         Part code 25815 Multi 9 - Acti 9 A9F44206

        Does the PDL 695/15 comply with AS/NZS 3112 standard

         Yes it does

        What is the replacement for 25018 MCB?

        The replacement for 25018 MCB is A9F54450
        A9F54450
        Acti9 iC60H 4P 50A C Miniature Circuit breaker
        For more information see:
        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F54450

        What is part number for 35/125 duct?

        The part number for 35/125 duct is a - PL35125D

        For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=PL35125DW

        What is the part code for a 1P 32A relay

         The part code is 15515

        What is the part code for a RCBO 4P 32Amp C-curve

         Combine a mccb 25016 32Amp C-curve with a 23382 rccb = RCBO

        What is the part code for a 2P 16A 6kA C-curve circuit breaker

         The part code is 25817

        What is the part code for the replacement rubber seal for PDL 14/15 Tuff light

        The part code is PDL20/8

        What is replacement for part number 25014?

        The replacement for part number is a 9f54420.

        Is the junction box 265/1 UV rated?

        No it doesn't have a rating as such, however it is UV resistant.

        Does Clipsal have a blank plate in the standard series, the same size as a 25/2?

        Yes we do, it's the 31/2VX-WE.

        What is the part code for a caravan lead with RCD 15m permanent connection

         The part code is PDL 953/15

        Is there a PDL 953/15 that is longer than 15m

         No not available 
        Please note this product is being phased out

        In the 600 Series, is the 691/15 available in RED

        Not available, but Clipsal 2015/15 is available in red but it's horizontal.

        Does 25/1510 have two separate connection for each outlet?

        Yes this plate has a 15A and a 10A outlet and they are separately wired.
        For further information please follow link below
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=25/1510

        What screws would suit a 265/1-GY.

        The part number for the screws would be 265SCREW.

        Does the 252/32/2A come in orange?

        No, the 252/32/2A only comes in grey.

        Is there a 15 amp plug available in the 900 series with lock ring?

        No, only the 905/15 is available without lock ring

        what is the Acti 9 code for Merlin Gerin 15515?

        A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

        What is part number for double GPO 15&10amp?

        Part number 25/1510 with 15amp & 10amp sockets & switches.

        Do you do the 265/1 in a orange colour?

        Yes, we can offer the 265/1 in electric orange. The part number is 265/1-EO.
        Some of the key features are:
        • Surface mount
        • Dimension: 77 mm Length x 77 mm Width x 54 mm Height
        • 63.5 mm screw centres C, 63.5 mm screw centres D
        • Weatherproof, full cover plate
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=265/1


         

        What is part number for mounting clip to suit 25/2V?

        The part number for mounting clip is a 154/2.

        Are the 265 series insulated boxes (suitable for numerous junctions and terminations) IP rated?

        The 265 series is a range of IP56 rated insulated boxes suitable for numerous junctions and terminations. Each box is supplied with a 3mm sealing gasket.

        This applies to the 265/1, 265/3, 265/4, 265/5, 265/7 and 265/7D.

        Will 25/2V double outlet, large size, vertical fit on 155P2 plaster bracket?

        Yes, 25/2V will fit on 155P2. 25/2V is  Large Size Format 115 x 115mm, Double Power Outlet rated to 250V 10A.
        For further information please visit:
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=25/2V
        User-added image

        155P2 is a large plaster mounting bracket with 84mm mounting centre. For further information please visit:
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=155P2
        User-added image
         

        What are the part number for a 15 amp outlet with RCD protection?

        Not available as 1 unit. Would have to use 2015/15 with 2031VRCD30
        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2015/15
        https://www.clipsal.com/Trade/search-results?q=2031VRCD30
        User-added image
        User-added image

        What is the part number for the Relay and RPO connector for the Conext CL inverters?

        One set of dry contact Relay and RPO connectors are provided along with the wiring box packaging.
        The Relay and RPO connector is included in a plastic bag with other connectors, if it is lost, you will have to purchase another one.
        The part number is 0J-0L2344 (Lit Kit IEC CL 20/25 kw Rohs package)

        What is the part number of the mounting block to suit 25/2V Standard range, double socket outlet, large size format 115 x 115mm?

        448SD and 448 are the mounting blocks to suit 25/2V, Standard range, double socket outlet, large size format 115 x 115mm.  Dimensions of the mounting block are as follows:

        For further information , please visit
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=448SD
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=448
        448SD
        User-added image
        448
        User-added image
         

        What is the part number for a replacement for 15/15/EL30?

        There is no direct replacement for this unit. Customer would be able to use 3 items to make this up - 2015/15 , 2031RC30 & 2000H2

        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2015/15
        https://www.clipsal.com/Trade/search-results?q=2031RC30
        https://www.clipsal.com/Trade/search-results?q=2000H2
        User-added image

        User-added image
        User-added image

        What are the part numbers of slip type expansion couplings?

        Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
        16mm = 251/16
        20mm = 251/20 *
        25mm = 251/25 *
        32mm = 251/32
        40mm = 251/40 *
        * = only available in Grey
        Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
        Dimension details are attached.
         

        Is there a skirting mount double power outlet rated to 15A, 250V?

        Unfortunately not, we do not have skirting mount double power outlet rated to 250V 15A .

        In 15A , 250V, skirting mount, we have the following options:

        16/15 -  Single Power Outlet 250V 15A, Skirting Mount, Plate size 98 x 41mm at centre.
        For further information, please visit
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=16/15

        16/2MF1510 - Double Power Outlet 250V 15A and 10A combination, Skirting Mount, suits ducting (156.5 x 44mm).
        For further information, please visit
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=16/2MF1510

         

        How to perform MSET on a BPH motor using Lexium 17/15 Servo Drive?



        Issue:  Although the BPH motors that are used with the Lexium 17 and 15 range of Servo drives are factory MSET, occasionally there may be a need to MSET this in the field due to commutation error being reported. 


        Product Line: Lexium BPH


        Environment:


        Cause: Due to an incorrect offset value set in the drive, the drive may report a F25, commutation error.


        Resolution: This resolution discusses the MSET procedure for a BPH motor with a Lexium 17/15 series drive.

         
        Proper commutation and position feedback are required to interface a particular servo drive and motor combination. When using Schneider Electric BPH motors and Lexium drives, this setup (or “characterization”) process has been completed and verified for the user at the factory. Occasionally there may be a need to MSET the BPH motor and this is detailed in this procedure.
         
        Perform the following steps, as described, and in the order presented, to complete the MSET procedure. 
         
        1.    Disconnect the Motor from the Mechanical Load
        2.    Electrical Connections
        A.   Verify that the required electrical connections for drive power, logic power, motor power and resolver are as described in the Lexium drive user manual.
        B.   Apply 24VDC logic and AC input power to confirm proper drive startup sequence and self-checks.
         
         Follow this MSET procedure only if the drive firmware is ver 5.51 and above.
         
         Connect to the drive using Hyperterm…
         
        1. Type OPMODE followed by Enter – note down the Opmode (xx) the drive is set to.
         
        1. Type OPMODE 2 followed by Enter – switch to digital torque mode
             C.     Type 'EN' followed by Enter.

             D.     Type "Zero" followed by ENTER - Motor shaft will jump to nearest pole. MPHASE value is automatically set.
         
          
        1. Type SAVE
         
        1. Type OPMODE xx followed by enter ( where xx is the default value that was originally set for the application.)
         
             G.    Type COLDSTART (the drive will reboot)
        This completes the MSET procedure.

        Where are I/O modules installed on a PM8000 meter

        Issue:
        User wants to know where to install I/O modules on a PM8000 meter.
         
        Product Line:
        PM8000 meters
        METSEPM89M2600 (Digital I/O module)
        METSEPM89M0024 (Analog I/O module)

        Environment:
        I/O modules installation

        Resolution:
        *Warning:  Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death.

        There are 2 methods to install I/O modules on a PM8000 meter. The method to choose will depend on your PM8000 model number

        If meter is PM8240 (Panel mount meter with integrated display)
        I/O module to be installed on the back of the meter. 
        1) remove connector's cover on back of the meter
        2) Make sure that connectors on meter and I/O module align with each other. Attach I/O module to the back of the meter.
        3) secure the I/O module in its location by a 5mm (5/16 in) screw
        4) reattach connector's cover that was removed in step 1 to the back of I/O module
        See illustration below:


        If meter is either PM8243 or PM8244 (DIN rail mount meter)
        I/O module to be installed on the side of the meter:
        1) remove connector's cover from side of the meter
        2) Hang the I/O module on your DIN rail
        3) Secure I/O module to the DIN rail using Mounting clip.
        4) Move I/O module using the DIN rail and attach it to the PM8000 meter> You should hear a click.
        5) Secure the I/O module to the meter using a 5mm (5/16 in) screw.
        6) reattach connector's cover that was removed in step 1 to the back of I/O module
        See illustration below:



         

        Soft starters and VSD Catalogue April 2003 (latest what I have in my hand) is not contains details about Interbus-S communication in Section 3, Commu...

        Goals and Symptoms

        Soft starters and VSD Catalogue April 2003 (latest what I have in my hand) is not contains details about Interbus-S communication in Section 3, Communication.
        There is only a short list on page 2/135 with the available solution.
        Why we have 3 different Part number in Vantive? In the catalog we have only the VW3-A58304E. Is it possible to buy VW3-A58304E, which not requires external power supply? If yes, it's missing from the Printed catalog.

        Would be nice to give detailed informations with each type of communication option board, like we provide for MBPLUS, FIPIO, ETHERNET in Section3. (I mean network topology, reccomendations, etc)
        Missing the Interbus-S, CAN-Open, Profibus-DP details there. Can-open will be intersting in point of communication, because Advantys and the new OEM strategy in Schneider is based on CAN!

        Pls see the possibility in the next version.

        Causes and Fixes

        VW3A58304 = First version, not recommended ( not exernal 24Vdc )
        VW3A58304E = Second version with an external 24Vdc to supply the option card even the ATV is switched off because Interbus-S is a circular ring and if a device is switched off, you loose the bus.
        VW3A58304EU = Version with USA documentation.

        For MBPLUS, Fipio, Ethernet you can find a large documentation in IANET, it's not possible to put more details in the catalog because it's a catalog and the customer or enginnering department is supposed to know the concerned field-bus.


        Legacy KB System (APS) Data: RESL160842 V1.0, Originally authored by on , Last Edited by on
        Related ranges: Altivar 58

        Which wall box suits the large size, twin socket outlet 25/2V?

        The wall box that suits the large size, twin socket outlet 25/2V is 257D2-GY.
        Its key features are:
        • 2 gang
        • 84 mm x 46 mm mounting center
        • Suits universal wall construction
        • With 20 mm cut-outs one end and 25 mm cut-outs at other, impact resistant, deep-type
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=257D2

        Are EasyPact CVS circuit breakers for sale in the USA or Canada?

        Product Line:
        EasyPact CVS circuit breakers

        Cause:
        This breaker is popular overseas and there is interest in the US

        Resolution:
        There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.

        Will the Compact NSX breaker be for sale in the USA or Canada?

        Issue:
        Where can I buy a Compact NSX breaker?

        Product Line:
        Circuit Breakers

        Cause:
        This breaker is popular overseas and there is interest in the US

        Resolution:
        There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

        If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

        For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
        https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page