Quantcast

Conduit Bend, Large Sweep, 90Deg, PVC, 100mm

Electric Orange | Conduit Bend, Large Sweep, 90Deg, PVC, 100mm

Conduit Bend, Large Sweep, 90Deg, PVC, 100mm

Item Number: 247P100-EO

Retail
$346.91
RRP (Inc. GST)
Colour Electric Orange (EO)
  • Electric Orange 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Series 247P

Sustainable offer status

Green Premium product

Physical

Length

900 mm

Standards

AS/NZS 2053

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP100802EN

Material

Material

PVC (polyvinyl chloride)

Others

Diameter

100 mm

Operating angle

90 °

Inner radius

600 mm

Package 1 Weight

2.1 kg

Package 1 Height

120 mm

Package 1 width

116 mm

Package 1 Length

640 mm
Show all specifications

Frequently Asked Questions

hide show

Are there Certificates of Conformity for the 247P100 and 262P100?

No. Unfortunately, there are not.

What is the radius of part no 247PH100

Bend Radius for 247PH100 is 715mm

ACRP100 Installation Manual

Issue:  
This article contains the full ACRP100 Installation Manual.

Product line:
ACRP100, ACRP101, ACRP102.

Environment:  
All Serial Numbers.    
 
Cause:   
Installation Manual.

Resolution:   
See File below

Is a 9007C62B2 a complete switch?

Issue:
Checking if the 9007C62B2 is a complete switch.

Product Line:
9007C Limit Switches

Environment:
9007C62B2

Resolution:
It is a complete switch body, but requires a lever arm. The lever arm is not included in the part number.

 

How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

Issue:
Implementing a hardwire stepdown transformer in a 208v or 240v environment


Product Line:

Smart-UPS / Symmetra

Environment:

APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

Cause:

Unbalanced UPS outputs require a stepdown transformer to power 120v loads


Resolution:

This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

The wiring block outputs are as follows:


For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



 Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

What wire size, type(solid or stranded), quantity and torque will all the PK3GTA through PK27GTA,Ground Bars accept that are used in QO and Homeline load centers?

Issue:
Product features

Product Line:
Load Center Ground Bars

Environment:
Wire range

Cause:
Wire installation

Resolution:
The terminals provided on the PK3GTA through PK27GTA ground bars will accept the following:
NOTES:
1) 
The ground bars will accept either solid or stranded type wires. 
2) As shown below the PK ground bars will accept Mutiple wires for certain sizes.
3) ONLY the PK27GTA comes standard with one lug that mounts to the TOP of the ground bar and will accept (1) #6 - 2/0 Cu/Al wire


Wire Sizes for ALL the PK3GTA through PK27GTA ground bars: 
(1) #14 - #4 CU / AL  
(2) #14 CU wires
(2) # 12 CU / AL wires
(2) #10 AL wires 

Torque requirements:
Wire range                             Torque LB-IN
(1) #4 CU / AL                            35
(1) #6 CU / AL                            35
(1) #8 CU / AL                            25
(1) #10 - 14 CU, #10 - 12 AL     20 
(2) #14 CU                                 25
(2) #12 CU / AL                          25
(2) #10 AL                                  25

SEE THE ATTACHMENT FOR THE DIMENSIONAL INFORMATION FOR THE GROUND BARS.

 
Show More