coupling conduit pvc 25mm

SoLid Fittings - PVC, PVC Couplings, 25mm

Catalogue Number: 242/25
coupling conduit pvc 25mm
Colour: Grey
Colour: Per UOM Std.
  • Electric Orange 1 PCE
  • Grey 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Series 242
Material
PVC (polyvinyl chloride)
Product destination
diameter: 25-25 mm tube
Length
42-42 mm
Standards
AS/NZS 2053
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the standard pack size of the 262/25?

The standard pack size of the 262/25 is 50

Some of the key features are:
  • Rigid Tube
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=262/25
 

Is part number 260/25 available in Orange?

No. Unfortunately, the 260/25 is only available in Grey.

Is part number 242/50 suitable for underground?

Yes. Part number 242/50 is suitable for underground.

What would be a longer screw to suit Clipsals round j-boxes (Junction Boxes)?

The part number would be 248/20 which is a combination screw head 20MM 3/16 BSW.

Does the 1240/25 series come with gaskets?

No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
For more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=1240

Whati s pitch thread for part number 1245/25?

Pitch thread is 1.5mm

What is the part number for a plug to suit the 240/25?

The part number for a plug to suit the 240/25/3 is a 220/25.
 

Can I get the 242/32 in orange?

Yes, the 32mm coupling is available in orange. The part number is 242/32-EO.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=242/32

 

Is there an extension ring to suit the 343?

Yes, there is the 93ER and also the 249/12 or 249/25.

What is the part number for 238A with 25mm spout?

The 238/25 has 1 x 25 mm spout & 2 x25 mm conduit entries.

Are the Clipsal Conduit Clips available in Electric Orange?

No, they are only available in grey.

This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

What is the part number for a surface mount enclosure to suit 319HP Pneumatic timer?

238/25 is a surface mount enclosure with 25mm end entries that will suit 319HP.

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238/25

What are the part numbers for the 25mm PVC saddles and spacers?

The part numbers are 261/25 for the saddles and 261S25 for the spacers. 

Some of the key features are:
  • 63mm Length x 20mm Width x 29mm Overall Height
  • 48mm Mounting Centre
For further information please visit https://www.clipsal.com/Trade/search-results?q=261/25



 

Comment fonctionne les compteurs d'energie de l'ATS48.

Goals and Symptoms

Comment fonctionne les compteurs d'énergie de l'ATS48.

Causes and Fixes

Il existe 2 compteurs:

- le compteur en kW ( puissance active ) de 0 à 999 kW;
- le compteur en kW/h qui nécessite le fonctionnement du démarreur pendant au moins une heure ( pour la première ). Son échelle est de 0 à 65535, soit 7,4 années ( 7j/7 et 24h/24 ).

What are the part numbers of slip type expansion couplings?

Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
16mm = 251/16
20mm = 251/20 *
25mm = 251/25 *
32mm = 251/32
40mm = 251/40 *
* = only available in Grey
Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
Dimension details are attached.
 

Can Power Supply ABL7RM 24025 be din rail mounted?

Yes, ABL7RM24025 can be din rail mounted, it also has 2 x 4mm panel mount holes.

 

What is the part number for the Relay and RPO connector for the Conext CL inverters?

One set of dry contact Relay and RPO connectors are provided along with the wiring box packaging.
The Relay and RPO connector is included in a plastic bag with other connectors, if it is lost, you will have to purchase another one.
The part number is 0J-0L2344 (Lit Kit IEC CL 20/25 kw Rohs package)

What are the pinouts for current inputs on the AMI0810 when using the FTW308 cable with pigtail leads ?

 

 

 
  : Here are the pin assignments for current inputs I0 - I7 when using the FTW308 cable and the BMXAMI0810 .
 
      
    Current input 0  +                   pins 1/3 blue/white & white/blue are jumped together
    Current input 0  common        pin 2 white/orange
 
    Current input 1  +                   pins 4/6  green/ white & white/green are jumped together
    Current input 1  common        pin 5 orange/white
 
    Current input 2  +                   pins 7/9 white/brown  & brown/white are jumped together
    Current input 2  common        pin 8   white/gray 
 
    Current input 3  +                   pins 10/12 blue/red & red/blue are jumped together
    Current input 3  common        pin 11 gray/white
 
    Current input 4  +                   pins 15 /17 red/ orange & orange/ red are jumped together
    Current input 4  common        pin 16 red/green
 
    Current input 5  +                   pins 18/20 brown/red & red/brown are jumped together
    Current input 5  common        pin 19 green/red  
 
   Current input 6  +                 pins 21/23 red/gray & gray/ red are jumped together
   Current input 6  common        pin 22 black/blue
 
   Current input 7  +                   pins 24/26 black/orange & orange/ black are jumped together
   Current input 7  common        pin 25 blue/black 


R-6-30-17

Legacy KB System (APS) Data: RESL211859 V1.0, Originally authored by DaSo on 06/21/2013, Last Edited by DaSo on 06/21/2013
Related ranges: Modicon M340

PowerSCADA Expert 8.2 Update 5 - Release Notes

Issue
What is new in PSE8.2 and a detailed listing of resolved problems and minor enhancements.

Product Line
PowerSCADA Expert 8.2 (PSE8.2)

Environment
Installer
 
Cause
A new PSE8.2 cumulative update release.

Resolution
PowerSCADA Expert 8.2 Update 5 - Release Notes
Release Notification (Updated 25 April 2018)

This is a detailed listing of resolved issues and minor enhancements in this release.

 


 

Prerequisite

You must have PowerSCADA 8.2 installed prior to installing this update. No previous updates are required.

Cybersecurity Announcement

Floating License Manager v2.1 addresses vulnerabilities in the Flexera FlexNet Publisher component detailed in CVE-2016-10395, CVE-2017-5571 and CVE-2016-2177. Uninstall the current version of the Floating License Manager, and then install version 2.1.
NOTE: The Floating License Manager v2.1 installer is included with this hotfix release but is not a part of the hotfix installer. Unzip "Floating License Manager v2.1.zip" and run "setup.exe".

Important Notice: There is a known issue with the Floating License Manager v2.1.0.0 installer. When installing with a logged-in Windows User name containing a space, the install will not succeed. The workaround is to install the Floating License Manager with a user that does not include a space character in their name.

Bug Fixes and Enhancements

TFS 21482 - AlarmEvents with a state of normal returned in GetAlarmEvents response for EWS

GetAlarmEvents was changed to not return alarms in the normal state.

TFS 21483 - Incorrect timestamp information provided for AlarmEvents not in the Active state

Alarm timestamps are now updated to reflect the true timestamp of occurrence for all state changes (active, drop out, acknowledge).

TFS 21484 - Unable to filter AlarmEvents by Type using EWS

Alarms are now filtered based on type. 

TFS 21485 - Unable to successfully acknowledge alarms using EWS

In some situations, EWS would not acknowledge alarms correctly.  This behavior has been fixed.

TFS 21486 - Unable to filter alarms using the PriorityTo and PriorityFrom fields

EWS did not observe the priority field correctly. This has been addressed and the minimum allowable priority has been set to 1 (to exclude non-alarm objects in the PowerSCADA alarm database).

TFS 21557 - PowerSCADA projects - including the starter project, PLS_Include, and PLS_Example - need to be upgraded to support the new DBF schemas

PowerSCADA projects have been upgraded to the latest DBF schemas.  If there are existing projects created from the starter project, set [CtEdit] Upgrade = 1 in the Citect.ini file using the Setup Editor, and then restart PowerSCADA Studio.

TFS 21564 - Alarm Proxy does not show the analog alarm states

Alarm Proxy now reports the analog alarm states (HIGH HIGH, HIGH, LOW, LOW LOW) instead of ON / OFF.

TFS 21566 - If a CSV file that does not exist is selected in the I/O Device Manager, the application throws a runtime exception

 

A message is displayed indicating that the file does not exist.

 

TFS 21569 - On large systems with 200k configured alarms, the GetAlarmDefinitions call in Alarm Proxy is slow and causes ENM to timeout

Performance issue in alarm proxy has been resolved.

TFS 21649 - When CoreServiceHost adds and removes devices, it may lose the original IDs

CoreServiceHost now keeps a device chronicle.  When the device is removed and then later added, the ID will remain the same.

TFS 21913 - If the equipment name is changed in the system, but the I/O Device name is unchanged, CoreServiceHost will not refresh the equipment name

CoreServiceHost now properly updates the equipment on name change.

TFS 21935 - Logs that are too large for the Windows Event Log do not get logged properly

Large logs are now broken down into smaller log entries.

TFS 21970 - Profile Wizard and Automation does not support IPv6

Profile Wizard and Automation now supports IPv6 for TCP/IP Board level drivers.  This requires the TCP/IP Driver version 4.0.0.0 or later.

TFS 21975 - Open and Close buttons are disabled at runtime on equipment popup when separate digital tags are used for commands

The form now enables the command buttons if the Pos_On or Pos_Off tags are defined.

TFS 21979 - Alarm Proxy cannot return alarms that transition to inactive

This setting is now configurable in the Application Configuration Utility.

TFS 22043 - Single sign-on calls from a remote thick client do not work

Single sign-on now detects remote clients.

TFS 22060 - The I/O Device Manager cannot bulk import devices with device names greater than 16 characters

The I/O Device Manager now reads the device name length from the equipment.profiles file for proper validation.

TFS 22066 - Wonderware ArchestrA Logger Security Patch

Wonderware ArchestrA Logger Patch 2017.517.2328.1 is applied.

TFS 22150 - Alarm filters do not work on some resolutions

Alarm filter AN numbers are fixed for all alarm page resolutions.

TFS 22155 - Alarm filters perform exact matching

The alarm filter screen allows the user to select the filtering mode. The default setting is read from the INI file [Alarm] FilterMode.  0 (default) = Exact Match, 1 = Starts With, 2 = Ends With, 3 = Contains.

TFS 22306 - The equipment tree used on alarm pages is slow to render over the web client

Any page using the equipment tree should set the default library and symbol on the equipment tree genie, or set 'Hide Symbol Icons' to 'TRUE' if a default icon is not available.

TFS 22401 - Alarm filter and equipment tree filter operate independently

The alarm filter and equipment tree filter operate together to filter the alarm tables.

TFS 22896 - Core service host logs two warnings during shutdown - exception thrown during disposal.

 

Cleanup methods were reworked to prevent the exception.

 

TFS 22898 - EWS cannot obtain tag updates at a 5 second rate

EWS and core services were updated to obtain data at a 5 second poll rate.

TFS 23262 - Equipment popup alarm table does not acknowledge or disable alarms

Alarms can now be acknowledged or disabled in the equipment page.

TFS 23274 - Equipment.profiles cannot be imported into the Profile Editor in cases where the original Device Types and Device Profiles were lost

The Profile Editor can import the equipment.profiles file to generate device types, device profiles, and tags.

TFS 23437 - Citect 2016 Updates

 

Citect 2016 Update (April 10, 2018) is included with this update.

Project ID management was removed from Citect 2016.  Project IDs are now located in the ProjectInfo.xml file. 

MinUnitNumber and MaxUnitNumber (previously stored in UnitNumberRange.xml) have also been migrated to ProjectInfo.xml.

 

TFS 23637 - The Alarm Summary page does not display state information

The Alarm Summary page now displays the state that caused the alarm.

TFS 23650 - 8.2 install does not enable ASP feature within IIS

The installer now enables the ASP feature under IIS. This server role feature is required to run the Citect web control client. (Previously the View-Only web client was the only option for web deployment.)

TFS 24205 - When Core Services receives a timeout from the Client, alarm processing may halt until the service is restarted

Core Services properly recovers from a ctApi deadlock condition.

Files Modified

Applications\AppServices\bin\Framework.dll
Applications\AppServices\bin\Framework.ServiceHost.exe
Applications\AppServices\bin\Modules.CoreServices.dll
Applications\AppServices\bin\PowerLogic.Cipher.dll
Applications\AppServices\bin\Modules.ProviderBase.dll
Applications\AppServices\bin\Modules.ProviderEngine.TestHarness.exe
Applications\AppServices\bin\ObjectFactoryTools.exe
Applications\AppServices\bin\ProviderGatewayProviders.dll
Applications\AppServices\bin\PowerSCADA.Common.dll
Applications\AppServices\bin\Modules.Platform.Citect.dll
Applications\EWS\bin\Framework.dll
Applications\EWS\bin\EWS.dll
Applications\EWS\Web.config
Applications\EWS\DataExchange.svc
bin\de\ProfileEngine.resources.dll
bin\de\ProfileWizard.resources.dll
bin\de\WizardLibrary.resources.dll
bin\es\ProfileEngine.resources.dll
bin\es\ProfileWizard.resources.dll
bin\es\WizardLibrary.resources.dll
bin\fr\ProfileEngine.resources.dll
bin\fr\ProfileWizard.resources.dll
bin\fr\WizardLibrary.resources.dll
bin\it\ProfileEngine.resources.dll
bin\it\ProfileWizard.resources.dll
bin\it\WizardLibrary.resources.dll
bin\ja\ProfileEngine.resources.dll
bin\ja\ProfileWizard.resources.dll
bin\ja\WizardLibrary.resources.dll
bin\ko\ProfileEngine.resources.dll
bin\ko\ProfileWizard.resources.dll
bin\ko\WizardLibrary.resources.dll
bin\ru\ProfileEngine.resources.dll
bin\ru\ProfileWizard.resources.dll
bin\ru\WizardLibrary.resources.dll
bin\zh-chs\ProfileEngine.resources.dll
bin\zh-chs\ProfileWizard.resources.dll
bin\zh-chs\WizardLibrary.resources.dll
bin\zh-cht\ProfileEngine.resources.dll
bin\zh-cht\ProfileWizard.resources.dll
bin\zh-cht\WizardLibrary.resources.dll
bin\ProfileAutomation.dll
bin\ProfileEngine.dll
bin\ProfileWizard.exe
bin\WizardLibrary.dll
bin\ProfileAutomationUtility.exe
bin\CommsMethodProperties.xml
bin\DeviceManagementUserControlLibrary.dll
Applications\Profile Editor\Tags.xml
Applications\Profile Editor\ProfileEditor.Business.dll
Applications\Profile Editor\ProfileEditor.exe
Applications\Profile Editor\ProfileEditor.UserControls.dll
Applications\Profile Editor\Resources\ProfileEditor.UserControls.resources
User\PLS_Include\*
User\PLS_Example\*
Starter\Default_Starter.ctz

Installation

Unzip "PowerSCADA Expert 8.2 Update 5.zip" and run "PowerSCADA Expert 8.2 Update 5.exe".