coupling conduit pvc 20mm

SoLid Fittings - PVC, PVC Couplings, 20mm

Catalogue Number: 242/20
coupling conduit pvc 20mm
Colour: Grey
Colour: Per UOM Std.
  • Electric Orange 1 PCE
  • Grey 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series 242
Material
PVC (polyvinyl chloride)
Product destination
diameter: 20-20 mm tube
Length
44-44 mm
Standards
AS/NZS 2053
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Is part number 242/50 suitable for underground?

Yes. Part number 242/50 is suitable for underground.

What would be a longer screw to suit Clipsals round j-boxes (Junction Boxes)?

The part number would be 248/20 which is a combination screw head 20MM 3/16 BSW.

Is there a 246/50 in orange?

Yes we do but it is manfactured to order.

Can I order the 220/20 in white?

Yes, you can order the 220/20 in white but it needs to be done as a special.
For more information, please refer to the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=220/20

Can I get the 242/32 in orange?

Yes, the 32mm coupling is available in orange. The part number is 242/32-EO.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=242/32

 

Do you have a cap/ flange to for 20mm conduit?

Yes the part number is 221/20

Are the Clipsal Conduit Clips available in Electric Orange?

No, they are only available in grey.

This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

What is the standard pack size of the 262/25?

The standard pack size of the 262/25 is 50

Some of the key features are:
  • Rigid Tube
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=262/25
 

Comment fonctionne les compteurs d'energie de l'ATS48.

Goals and Symptoms

Comment fonctionne les compteurs d'énergie de l'ATS48.

Causes and Fixes

Il existe 2 compteurs:

- le compteur en kW ( puissance active ) de 0 à 999 kW;
- le compteur en kW/h qui nécessite le fonctionnement du démarreur pendant au moins une heure ( pour la première ). Son échelle est de 0 à 65535, soit 7,4 années ( 7j/7 et 24h/24 ).

What are the part numbers of slip type expansion couplings?

Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
16mm = 251/16
20mm = 251/20 *
25mm = 251/25 *
32mm = 251/32
40mm = 251/40 *
* = only available in Grey
Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
Dimension details are attached.
 

How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

Issue:
Implementing a hardwire stepdown transformer in a 208v or 240v environment


Product Line:

Smart-UPS / Symmetra

Environment:

APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

Cause:

Unbalanced UPS outputs require a stepdown transformer to power 120v loads


Resolution:

This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

The wiring block outputs are as follows:


For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



 Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

What are the pinouts for current inputs on the AMI0810 when using the FTW308 cable with pigtail leads ?

 

 

 
  : Here are the pin assignments for current inputs I0 - I7 when using the FTW308 cable and the BMXAMI0810 .
 
      
    Current input 0  +                   pins 1/3 blue/white & white/blue are jumped together
    Current input 0  common        pin 2 white/orange
 
    Current input 1  +                   pins 4/6  green/ white & white/green are jumped together
    Current input 1  common        pin 5 orange/white
 
    Current input 2  +                   pins 7/9 white/brown  & brown/white are jumped together
    Current input 2  common        pin 8   white/gray 
 
    Current input 3  +                   pins 10/12 blue/red & red/blue are jumped together
    Current input 3  common        pin 11 gray/white
 
    Current input 4  +                   pins 15 /17 red/ orange & orange/ red are jumped together
    Current input 4  common        pin 16 red/green
 
    Current input 5  +                   pins 18/20 brown/red & red/brown are jumped together
    Current input 5  common        pin 19 green/red  
 
   Current input 6  +                 pins 21/23 red/gray & gray/ red are jumped together
   Current input 6  common        pin 22 black/blue
 
   Current input 7  +                   pins 24/26 black/orange & orange/ black are jumped together
   Current input 7  common        pin 25 blue/black 


R-6-30-17

Legacy KB System (APS) Data: RESL211859 V1.0, Originally authored by DaSo on 06/21/2013, Last Edited by DaSo on 06/21/2013
Related ranges: Modicon M340