box junct round 3way 20mm

Junction and Adaptable Boxes PVC, Round Junction Boxes - 20mm Entries, 3 Way

Catalogue Number: 240/20/3
box junct round 3way 20mm
Retail
$17.70
RRP (Inc. GST)
Colour Grey (GY)
  • Grey 1 PCE
  • Electric Orange 1 PCE

Specifications

hide show
Range of product
Series 240
Product brand
Clipsal
Material
PVC (polyvinyl chloride)
Shape
round
Package 1 Weight
0.088 kg
Package 1 Height
40 mm
Package 1 width
80 mm
Package 1 Length
96 mm
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Frequently Asked Questions

hide show

What is the part number for a plug to suit the 240/25?

The part number for a plug to suit the 240/25/3 is a 220/25.
 

What is the part number of a Junction box with 25mm entry but entries in U shape?

Unfortunately we dont make U entry junction box any more, closest will be 240/25/2A and similar.

What edition of SQL Server 2000 is installed with System Manager Software (SMS) Professional Edition (PE) 4.0?

The SQL Server 2000 edition is operating system dependant:
Windows XP Professional installs SQL2K_Personal edition
Windows 2000/2003 Server installs SQL2K_Standard edition


Legacy KB System (APS) Data: RESL201502 V1.0, Originally authored by MaTh on 03/02/2010, Last Edited by MaTh on 03/02/2010
Related ranges: System Manager 4.0

What is the part number for din mounted transformer 240/24V AC 60VA?

The part number for din mounted transformer 240/24V AC 60VA is ABL6TS06B + ABL6AM02
+ Related image

  ABL6TS06B                                                                             ABL6AM02
voltage transformer - 230..400 V - 1 x 24 V - 63 VA                     plate for mounting on symmetrical DIN rail - for voltage transformer

For more information see:

https://www.schneider-electric.com/en/product-range-selector/1537-phaseo-abt7--abl6/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecatalogue%2Fbrowse.do%3Fel_typ%3Dproduct%26cat_id%3DBU_AUT_1537_L3%26prd_id%3DABL6TS06B%26scp_id%3DZ000                                                      
                                                                                                                                         

How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

Issue:
Implementing a hardwire stepdown transformer in a 208v or 240v environment


Product Line:

Smart-UPS / Symmetra

Environment:

APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

Cause:

Unbalanced UPS outputs require a stepdown transformer to power 120v loads


Resolution:

This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

The wiring block outputs are as follows:


For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



 Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

Is there an alternative for 1239/20/1, Round, 20mm, 1 Way Entry, Light Duty Junction Box?

 Yes, however the alternatives may vary in style, material or number of entries.

The closest alternative in galvanised cast iron is a Junction Box, Round- 20mm I.D, 1 Way Entry, Heavy Duty. The Part number is 1239H20/1.
The closest alternative in PVC is a Junction and Adaptable Boxes PVC- 20mm Entries, 1 Way. The partn number is 240/20/1.

For further information please visit https://www.clipsal.com/Trade/searchround/jbox20MMENTRY1



             1239/20/1                          1239H20/1                           240/20/1                           



 

What is the part number for a Contactor with Low consumption?

The part number for a low consumption contactor is LC1D09.
General Product information:
Range of product TeSys D
Product or component type Contactor
Device short name LC1D
Contactor application Motor control Resistive load
Utilisation category AC-1, AC-3
Poles description 3P
Power pole contact composition 3 NO
[Ue] rated operational voltage <= 300 V DC for power circuit
<= 690 V AC 25...400 Hz for power circuit
[Ie] rated operational current 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
Motor power kW 5.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 500 V AC 50/60 Hz
4 kW at 415...440 V AC 50/60 Hz
4 kW at 380...400 V AC 50/60 Hz
2.2 kW at 220...230 V AC 50/60 Hz
Motor power HP (UL / CSA) 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
Control circuit type AC 50/60 Hz
Control circuit voltage 415 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A at <= 60 °C for signalling circuit
25 A at <= 60 °C for power circuit



For more information please visit https://www.schneider-electric.com.au/en/productcontaLC1D