Quantcast

Back Entry Lid, Round, 1mm

Grey | Back Entry Lid, Round, 1mm

Back Entry Lid, Round, 1mm

Item Number: 240/16BL-GY

Retail
N/A
RRP (Inc. GST)
Colour Grey (GY)
  • Grey 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Product or component type

lid

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Others

Mounting location

back side

Package 1 Weight

0.02 kg
Show all specifications

Frequently Asked Questions

hide show

What is the rating of transformer in the PDL shaver sockets

Rating are 240/115V 20va

What colours is the 4061PBL available in?

4061PBL-HB
4061PBL-HS
 
4061PBL-EB
4061PBL-PW
4061PBL-OM 
 
Z4061PBL-ZW
Z4061PBL-ZB

Will a 30USBC mech fit a 4061VH or similar plates?

No, a 30USBC mech will not fit a 4061VH or 4061PBL or similar plates
30USBC mechs will only fit a 4031VH or similar communication plates as 30USBC is a 30 series style of mech

What is the part number for a cover only for a Saturn series 1 gang switch , 4061PBL?

The part number for a cover only for a Saturn series 1 gang switch , 4061PBL is - 4061PBC

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=4061PBC
User-added image

What are the part numbers for a Saturn Horizon Silver 1 & 2 gang switches ?

The part numbers for a Saturn Horizon Silver 1 & 2 gang switches are - 4061PB or 4061PBL & 4062PB or 4062PBL
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=4061PB
https://www.clipsal.com/Trade/search-results?q=4061PBL
https://www.clipsal.com/Trade/search-results?q=4062PB
https://www.clipsal.com/Trade/search-results?q=4062PBL
User-added image
User-added image


User-added image
User-added image

How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

Issue:
Implementing a hardwire stepdown transformer in a 208v or 240v environment


Product Line:

Smart-UPS / Symmetra

Environment:

APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

Cause:

Unbalanced UPS outputs require a stepdown transformer to power 120v loads


Resolution:

This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

The wiring block outputs are as follows:


For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



 Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.