box junct round 3way 16mm

Junction and Adaptable Boxes PVC, Round Junction Boxes - 16mm Entries, 3 Way

Catalogue Number: 240/16/3
box junct round 3way 16mm
Colour: Grey
Colour: Per UOM Std.
  • Grey 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 240
Product brand
Clipsal
Material
PVC (polyvinyl chloride)
Shape
round
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the part number for a plug to suit the 240/25?

The part number for a plug to suit the 240/25/3 is a 220/25.
 

What is the rating of transformer in the PDL shaver sockets

Rating are 240/115V 20va

Is a 30USM-WE a normal switch rocker mechanism

30USM-WE = Universal switch mechanism 20/16AX - compared to the 10A only 30M-WE
(see attached 30USM Brochure)

What voltage is the XB4BD33 rated for?

Issue:
What voltage is the XB4BD33 rated for?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Cause:
Product Features

Resolution:
The XB4 standard contact blocks are rated for 600 VAC.

Characteristics Conforming to IEC/EN 60947-5-1
Utilization category AC-15
Standard blocks (single or double) with screw clamp terminals:
A600: Ue = 600 Vac and le = 1.2 A or Ue = 240 Vac and le = 3 A
or Ue = 120 Vac and le = 6 A
Continuous Thermal Current = 10 A
Blocks for plug-in connector:
A300: Ue = 120 Vac and le = 6 A or Ue = 240 Vac and le = 3 A
Standard blocks for printed circuit board connection:
B300: Ue = 120 Vac and le = 3 A or Ue = 240 Vac and le = 1.5 A


CTA-ID : 2011683

How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

Issue:
Implementing a hardwire stepdown transformer in a 208v or 240v environment


Product Line:

Smart-UPS / Symmetra

Environment:

APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

Cause:

Unbalanced UPS outputs require a stepdown transformer to power 120v loads


Resolution:

This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

The wiring block outputs are as follows:


For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



 Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

What are the minimum required clearances for the ATS48 unit for enclosure mounting.

Issue:
What are the minimum clearances required on the ATS48 soft starters?

Product line:
Altistart 48, ATS48

Environment:
all

Cause:
Mounting inside an enclosure

Resolution:
There is a minimum of 4 inches (100 mm) on the top and bottom of the softstart.  A minimum clearance of 2 inches (50mm) on each sides.
The enclosure must also allow for proper ventilation to maintain a temperature of 40C (104F) and required wire bending space.