Mounting Box, 1 Gang, 4 Way, 20mm Entry

Mounting Box, 1 Gang, 4 Way, 20mm Entry

Mounting Box, 1 Gang, 4 Way, 20mm Entry

Item Number: 238B-WE

Retail
$31.89
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

Number of gangs

1 gang

Device mounting

surface

Length

115 mm

Depth

38 mm

EU RoHS Directive

Under investigation

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Material

Material

plastic

Others

Shape

rectangular

Cable entry number

4

Package 1 Weight

142 g

Package 1 Height

37 mm

Package 1 width

110 mm

Package 1 Length

115 mm
Show all specifications

Frequently Asked Questions

hide show

What is the part number for 238A with 25mm spout?

The 238/25 has 1 x 25 mm spout & 2 x25 mm conduit entries.

Part numbers for replacement phoenix contact connectors for common ION and Powerlogic meters and gateways.

Issue
A user would like a replacement terminal connector for an ION or Powerlogic meter or gateway

Product Line
ION6200 Series meters
ION7300 Series meters
ION7500/7600/7550/7650 Series meters
PM5000 Series meters
PM8000 Series meters
EGX100/300 Gateways

Environment
Power Monitoring
Energy Management


Cause
Replacement parts needed for Phoenix contacts.

Resolution
Schneider Electric does not sell the connectors. A distributor who sells PhoenixContact connectors is required. The parts are referred to as terminal block plugs. Common connectors and the PhoenixContact part number are shown below.
 
ION6200 Connectors

Phoenix Contact part #

Control Power 1900785
 
ION7300 Connectors

Phoenix Contact part #

Control Power 1767012
Analog Input 4 x 1803578
Analog Output 1803604
Digital Output 1803617
Communications 1803617
 
ION7330 & ION7350
ION 7550

Phoenix Contact part #

Control Power 1767012
Digital Input 1803604
Digital Output 1803617
Communications 1803617
 
ION7550 & ION7650
Connectors

Phoenix Contact part #

Control Power 1767012
Digital Input 1900840
Digital Output 1900837
Analog Input 1900837
Communications 1792281

 
PM8000 PM 5000

Phoenix Contact part #

Control Power 1745629
Digital Input 1900811
Digital Output 1900772
RS485 1900798
Voltage Input 1745645
 
PM5000 EX

Phoenix Contact part #

Control Power 1745629
Relays 1900798
Inputs/Outputs 1840405
Voltage Input 1745645
 
EGX100/EGX300 Conectors

Phoenix Contact part #

Control Power 1900772
Communications 1900808


Note: All these connectors are green

Do you do a 238 mounting block with a 50mm entry?

No, unfortunately the 238/25 has the largest conduit entry with a 25mm entry at each end.

For further information please visit https://www.clipsal.com/Trade/search-results?q=238/25

Does Clipsal do a 238 with 25mm entries, top and bottom?

No we don't. The closest we get is the 238A/25 with one 25 entry on the top.

What is the part number for a 238 in black?

The part number for a 238 in black is 238-BK.

Some of the key features are:
  • 1 gang
  • 84 mm mounting center
  • Horizontal and vertical mounting direction
  • 2 way
  • Suitable for 1 outlet
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238




 

What are the battery specifications for the Quantum PLCs?

Issue
Battery Specifications

Product Line
Modicon Quantum 

Resolution
The shelf life of the Quantum battery 990XCP98000 is 10 years with 0.5% loss of capacity per year. The same specifications applies to a PLC in the on condition 24x7.
With the PLC in the off condition, the battery will maintain the memory to the following PLCs as indicated:

140CPU11302 454 days
140CPU11303 238 days
140CPU21304 454 days
140CPU42402 238 days
140CPU43412X 238 days
140CPU53414X 119 days

Is there an insulated version of 450VC vertical corrugated iron mounting block?

Unfortunately, we do not have an insulated version of 450VC. Depending on the requirement we have 238 mounting boxes or the black plastic insulating shroud which can be used with 450VC. Customer needs to ensure they are following the wiring regulation. 

For further information, please visit 
https://www.clipsal.com/Trade/Products/ProductDetail?catno=238 
https://www.clipsal.com/Trade/search-results?q=insulating%20shroud


238

How to configure the SER2408/3200 device to work with the Generator Performance module in PME.

Issue
When attempting to assign I/O in the generator performance module, one is unable to locate all input assignments.

Product Line
Power Monitoring Expert 8.x
Data center Edition
Health Care Edition

Environment
Generator Performance module 
Data center

Cause


Resolution
Before the device can be properly configured in the Generator Performance Configuration Tool it must first be configured and added into PME properly.
After device data is logged into the database, you can assign device measurements using the Generator Performance Configuration Tool with EPSS Test Module.

Please refer to page 238 of t he Applications modules configuration guide for instructions on configuring the SER hardware.
 

Details Returned from APC Devices via Advanced Device Crawlers

Issue:

Details Returned from APC Devices via Advanced Device Crawlers

Product Line:

NetBotz

Environment:

NetBotz version 2 Advanced Device Crawlers.

Cause:

The following information can be queried via Advanced Device Crawlers for APC UPS systems assuming the APC DDF (Device Definition File) is installed on the NetBotz appliance and the APC UPS is SNMP enabled. Please note that not all information listed below is available on all APC models.

Resolution:

 
  • Battery Status
  • Time On Battery
  • Remaining Battery Capacity
  • Internal UPS Temperature
  • Battery Run Time Remaining
  • Battery Replace Indicator
  • Number of External Battery Packs
  • Number of Bad External Battery Packs
  • AC Input Phase
  • Utility Line Voltage
  • Maximum Utility Line Voltage Last Minute
  • Minimum Utility Line Voltage Last Minute
  • Input Frequency
  • Reason For Last Transfer to Battery Power
  • UPS Status
  • Output Phase
  • Output Voltage
  • Output Frequency
  • Current UPS Load - Rated Capacity
  • Current Load Draw on UPS
  • Nominal Output Voltage
  • Maximum Line Voltage Before Switching to Battery
  • Minimum Line Voltage Before Switching to Battery
  • Ambient Temperature Probe 1
  • Relative Humidity Probe 1
  • Ambient Temperature Probe 2
  • Relative Humidity Probe 2
  • Outlet Control
  • Overload Condition
  • Low Load Condition
  • Current Load
  • Outlet Control
  • MSP Outlet Control
  • Nominal Battery Voltage
  • Actual Battery Voltage
  • Battery Current
  • Total DC Current
  • DC Power Plant Model Number
  • Automatic Transfer Switch Model Number