Mounting box 20mm entries
box mounting pvc rect 3 ent
Mounting box 20mm entries
box mounting pvc rect 3 ent

Surface Enclosures, Mounting Box With 20 mm End Entries - 20 mm Spout One Side

Catalogue Number: 238A
Mounting box 20mm entries
box mounting pvc rect 3 ent
Mounting box 20mm entries
box mounting pvc rect 3 ent
Colour: White Electric
Colour: Per UOM Std.
  • Grey 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Number of gangs
1 gang
Shape
rectangular
Device mounting
surface
Cable entry number
3
Material
plastic
Length
115 mm
Depth
38 mm
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the part number for 238A with 25mm spout?

The 238/25 has 1 x 25 mm spout & 2 x25 mm conduit entries.

Part numbers for replacement phoenix contact connectors for common ION and Powerlogic meters and gateways.

Issue
A user would like a replacement terminal connector for an ION or Powerlogic meter or gateway

Product Line
ION6200 Series meters
ION7300 Series meters
ION7500/7600/7550/7650 Series meters
PM5000 Series meters
PM8000 Series meters
EGX100/300 Gateways

Environment
Power Monitoring
Energy Management


Cause
Replacement parts needed for Phoenix contacts.

Resolution
Schneider Electric does not sell the connectors. A distributor who sells PhoenixContact connectors is required. The parts are referred to as terminal block plugs. Common connectors and the PhoenixContact part number are shown below.
 
ION6200 Connectors

Phoenix Contact part #

Control Power 1900785
 
ION7300 Connectors

Phoenix Contact part #

Control Power 1767012
Analog Input 4 x 1803578
Analog Output 1803604
Digital Output 1803617
Communications 1803617
 
ION7330 & ION7350
ION 7550

Phoenix Contact part #

Control Power 1767012
Digital Input 1803604
Digital Output 1803617
Communications 1803617
 
ION7550 & ION7650
Connectors

Phoenix Contact part #

Control Power 1767012
Digital Input 1900840
Digital Output 1900837
Analog Input 1900837
Communications 1792281

 
PM8000 PM 5000

Phoenix Contact part #

Control Power 1745629
Digital Input 1900811
Digital Output 1900772
RS485 1900798
Voltage Input 1745645
 
PM5000 EX

Phoenix Contact part #

Control Power 1745629
Relays 1900798
Inputs/Outputs 1840405
Voltage Input 1745645
 
EGX100/EGX300 Conectors

Phoenix Contact part #

Control Power 1900772
Communications 1900808


Note: All these connectors are green

What is the part number of a 23A -32A overload to fit LC1D40U7 contactor?

LRD3353 is a 23A -32A overload to fit LC1D40U7 contactor. 
For further information, please visit https://www.schneider-electric.com/en/product/LRD3353/tesys-lrd-thermal-overload-relays---23...32-a---class-10a



 

Do you do a 238 mounting block with a 50mm entry?

No, unfortunately the 238/25 has the largest conduit entry with a 25mm entry at each end.

For further information please visit https://www.clipsal.com/Trade/search-results?q=238/25

Does Clipsal do a 238 with 25mm entries, top and bottom?

No we don't. The closest we get is the 238A/25 with one 25 entry on the top.

What is the part number for a 238 in black?

The part number for a 238 in black is 238-BK.

Some of the key features are:
  • 1 gang
  • 84 mm mounting center
  • Horizontal and vertical mounting direction
  • 2 way
  • Suitable for 1 outlet
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238




 

Is there an insulated version of 450VC vertical corrugated iron mounting block?

Unfortunately, we do not have an insulated version of 450VC. Depending on the requirement we have 238 mounting boxes or the black plastic insulating shroud which can be used with 450VC. Customer needs to ensure they are following the wiring regulation. 

For further information, please visit 
https://www.clipsal.com/Trade/Products/ProductDetail?catno=238 
https://www.clipsal.com/Trade/search-results?q=insulating%20shroud


238

What is the coil consumption or burden for the Tesys LC*D** contactors?

* 1 or 2
** 09 through 38

Issue:
Coil consumption or burden for the Tesys LC1D/2D contactors from 9A - 38A

Product Line: 
Contactors and Starters - IEC

Environment:
North American Products

Resolution:
All AC coils for the LC1D09 through LC1D38 3-pole contactors ( including ring tongue, quick connect and spring terminal versions ) have an inrush of 70 volt-amps for either 50 or 60 Hertz applications, and a sealed value of 7 volt-amps for 50Hertz applications or 7.5 volt-amps for 60 Hertz applications.

How to configure the SER2408/3200 device to work with the Generator Performance module in PME.

Issue
When attempting to assign I/O in the generator performance module, one is unable to locate all input assignments.

Product Line
Power Monitoring Expert 8.x
Data center Edition
Health Care Edition

Environment
Generator Performance module 
Data center

Cause


Resolution
Before the device can be properly configured in the Generator Performance Configuration Tool it must first be configured and added into PME properly.
After device data is logged into the database, you can assign device measurements using the Generator Performance Configuration Tool with EPSS Test Module.

Please refer to page 238 of t he Applications modules configuration guide for instructions on configuring the SER hardware.
 

Details Returned from APC Devices via Advanced Device Crawlers

Issue:

Details Returned from APC Devices via Advanced Device Crawlers

Product Line:

NetBotz

Environment:

NetBotz version 2 Advanced Device Crawlers.

Cause:

The following information can be queried via Advanced Device Crawlers for APC UPS systems assuming the APC DDF (Device Definition File) is installed on the NetBotz appliance and the APC UPS is SNMP enabled. Please note that not all information listed below is available on all APC models.

Resolution:

 
  • Battery Status
  • Time On Battery
  • Remaining Battery Capacity
  • Internal UPS Temperature
  • Battery Run Time Remaining
  • Battery Replace Indicator
  • Number of External Battery Packs
  • Number of Bad External Battery Packs
  • AC Input Phase
  • Utility Line Voltage
  • Maximum Utility Line Voltage Last Minute
  • Minimum Utility Line Voltage Last Minute
  • Input Frequency
  • Reason For Last Transfer to Battery Power
  • UPS Status
  • Output Phase
  • Output Voltage
  • Output Frequency
  • Current UPS Load - Rated Capacity
  • Current Load Draw on UPS
  • Nominal Output Voltage
  • Maximum Line Voltage Before Switching to Battery
  • Minimum Line Voltage Before Switching to Battery
  • Ambient Temperature Probe 1
  • Relative Humidity Probe 1
  • Ambient Temperature Probe 2
  • Relative Humidity Probe 2
  • Outlet Control
  • Overload Condition
  • Low Load Condition
  • Current Load
  • Outlet Control
  • MSP Outlet Control
  • Nominal Battery Voltage
  • Actual Battery Voltage
  • Battery Current
  • Total DC Current
  • DC Power Plant Model Number
  • Automatic Transfer Switch Model Number