Quantcast

Cable Management Pressed Metal Conduit Fittings, Conduit Size Earth Clip 20mm

Cable Management Pressed Metal Conduit Fittings, Conduit Size Earth Clip 20mm

Cable Management Pressed Metal Conduit Fittings, Conduit Size Earth Clip 20mm

Item Number: 207M

Retail
$6.49
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110719EN

Others

Package 1 Weight

24 g

Package 1 Height

10 mm

Package 1 width

70 mm

Package 1 Length

95 mm
Show all specifications

Frequently Asked Questions

hide show

What is the part number of an hot dip galvanized earth clip to suit 3/4" conduit?

207M is a hot dip galvanized earth clip to suit 3/4"  or 20mm conduit. 

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=207M


 

Is part number 209M available in Stainless Steel?

The part number 209M is not available in Stainless.

What would be the part number for an Earth Clip, 16/20 mm.

203M.
Pressed Metal Conduit Fittings, Earth Clips, Water pipe adjustable earth clip 15 - 20mm or 1/2 - 3/4 inch.
Please see following link under the documentation tab for full catalogue.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=203M

"The port is in use or an attempt was made to access a socket in a way forbidden by its access permissions." when starting PowerLogic SCADA Runtime

Goals and Symptoms

The following error message appears in PowerLogic SCADA (PLS) v7.10 after starting Runtime:
Cannot Open Server <ServerName>. The port is in use or an attempt was made to access a socket in a way forbidden by its access permissions.

As a result, the IO Server will not start.

Causes and Fixes

The default port used by the I/O Server is 2078. The above issue can be resolved by assigning a different port to the IO Server in the Servers > I/O Server field in the Project Editor.



For a complete list of default ports used in PLS, refer to the System Integrator Manual (search for 'default port'). Here are a few:

2075 Reports server communications
2076 Alarm server communications
2077 Trends server communications
2078 Legacy I/O communications
2082 Publish subscribe I/O server communications

To determine which ports are already in use, open a Command Prompt window and run the command 'netstat -a'. This will list all of the TCP port numbers currently in use in the system.

For additional information, refer to RESL197082.

Keywords: PLSCADA, PL SCADA, PowerSCADA, Power SCADA, StruxureWare PowerSCADA Expert, SPE 7.1, 7.2, 7.10, 7.20, net stat


Legacy KB System (APS) Data: RESL209208 V1.0, Originally authored by AnVa on 09/27/2012, Last Edited by AnVa on 09/27/2012
Related ranges: PowerLogic SCADA 7.1, PowerSCADA Expert 7.2

What is the part number for a 20mm conduit cap?

The part number for a 20mm conduit cap is- 262/20

 

What is part number for 20mm HFT corrugated conduit?

The part number for 20mm HFT corrugated conduitart is 9020CHF.
Show More