switch vingcard 4x16a 250v

Switch Vingcard 4X16A 250V

Catalogue Number: 2036VC4
switch vingcard 4x16a 250v
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Device presentation
basic element with full cover plate
Actuator
vingcard
Local signalling
without
[Ue] rated operational voltage
250 V AC
Rated current
16 A
Marking
without marking
EU RoHS Directive
Compliant
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Product Environmental

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the part number for the key only for the 2036VKT4?

The part number for the key only for the 2036VKT4 is 2036VKT.

Some of the key features are:
  • To suit 2036VKT and 36VKT series switches
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2036VKT
 

What is the white cover plate for a 2031VCS

The part code is 2000-WE surround cover plate

Can I purchase a replacement mechanism for the 2033CC & C2033CC credit card switches?

Yes, a 2036VC-4-WE  16A mechanism would suit the 2033CC & C2033CC ving card switches.

For further information please visit https://www.clipsal.com/Trade/search-results?q=2036VC-4-WE.

What is the software for programming the Zelio SR2 and SR3 Smart Relays?

Issue:
What is the software for programming the Zelio SR2 and SR3 Smart Relays?

Product Line:
Relays and Timers

Environment:
All Products

Cause:
Product Features

Resolution:
The software is zelio soft, which can be purchased as: SR2SFT01


CTA-ID : 2036494

Do you make a 2031VHA like the 2032VHA?

Unfortunately, we only make a 2 gang version.

Can mechs in part number 2036CC3N be changed?

Yes. Mechs cant be changed in part number 2036CC3N.

Does the 2031V66 come in architrave?

No it doesnt

What is the card for 2033cc1 credit card switch

This is not done by clipsal but an outside contractor please  contact PLACARD in NSW on 02 9588 8200 Contact Helen Perente

Do you do the 2031V66 with double pole switches?

No, the 2031V66 does not have double pole mechanisms.

Some of the key features are:
  • Switches have been re-designed to provide mechanisms that can be re-orientated horizontally or vertically
  • 1 gang weatherproof switch

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

Can the grid for the 2031v66 be purchased without mechs?

No, We do not supply or encourage this as the 2031v66 has a specific gasket set up to ensure weatherproof rating and this may be compromised if tampered with therefore we only sell them assembled.

What is the mech that fits in the 2031V66 switch?

Unfortunately we dont do the mech as a spare part it is essentually a 30 mech with a rubber seal between the contacts ant the dolly and we dont do that mech as a spare part.

Can part number 30M35 be used in 2031V66?

No. Unfortunately, part number 30M35 CANNOT be used in 2031V66.

 

What is the normal operating temperature for a QO breaker?

Product Line:
Circuit Breakers
QO 

Environment:
Electrical Distribution Equipment

Resolution:
Normal operating temperature will depend on breaker rating, load carried, proximity, loading, and type of other breakers in the panel, and ambient temperature.


 

What is the accuracy of the KWH or MWH power meter for the ATV58 type drives?

Issue:   What is the accuracy of the KWH or MWH power meter for the ATV58 type drives?
 
Product Line:   ATV58
 
Environment:  All
 
Cause:   KHW MWH accuracy
 
Resolution:   
The kW and kWH measurements have +/- 5% accuracy.
The drive calculates the kW and kWH rather than making actual power measurements to the motor.
Information provided by the PLE (Product Line Engineer), Chuck Cudlipp.


 

What is the part number for a flip cover for the 22mm pushbutton operators?

Issue:
What is the part number for a flip cover for the 22mm pushbutton operators?

Product Line:
Harmony Pushbuttons

Environment:

All Products

Cause:
Product selection

Resolution:
Use the ZB4BZ62 for black or ZB4BZ64 for red cover. This cover is padlockable.


 

Is there an XB4 or XB5 push to test pilot light?

Issue:
Are push to test pilot lights available for 22mm?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Resolution:
There is no push to test operator set up. Suggest using an illuminated pushbutton with (1) NO and (1) NC contact. The normal pilot light circuit is wired through the normally closed contact, and the test circuit is wired through the normally open contact. Customer will also have to jumper between the contacts.
 

Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

Issue:
Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
 
Product Line:

Tesys GV Manual Starter and Protectors

Environment:
TeSys GV, GVA, GV2, GV3P

Resolution:
These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

What is a Harmonic Mitigating Transformer?

Issue:
Harmonic Mitigating Transformers

Product Line:
LV Transformers

Environment:
Applies to Low Voltage Transformers by SquareD/Schneider Electric

Cause:
Some electrical equipment can generate harmonic energy which can produce harmful heating effects

Resolution:
Harmonic Mitigating Transformers are special types of Transformers that use phase shifting, electromagnetic flux, and source impedance to help reduce harmonics in electrical distribution systems.

Is there a mechanical interlock for the U-line starter?

Issue:
Checking for a mechanical interlock for the U-line starter.

Product Line:
Tesys U Starters

Environment:
IEC Contactors and Starters

Resolution:
No, you cannot interlock two seperate U-Lines together to make a reversing device. Instead the reversing block takes care of the reversing and interlocking internally.

 

What is the temperature rating of the 9080LBA power distribution blocks?

Issue:
9080LBA363106 operating temperature

Product Line:
9080LB, Power Distribution Blocks

Environment:
NEMA Type LB Power Distribution Blocks

Resolution:
The 9080LB distribution blocks temperature range is:
-40 to +302 degrees F
-40 to +150 degrees C

The miniature blocks (Part numbers 9080LBA161101, 9080LBA361101, 9080LBA161104, 9080LBA261104 and 9080LBA361104) are:
-40 to +266 degrees F
-40 to +130 degrees C

With an Econo-flex® drive, when adding the 0-10 Vdc to 4-20 mAdc Converter Kit 31158-297-50, how should it be connected?

Place the kit into the control terminals on the control board so that the +24 terminal on the kit connects to the +24 terminal in the control board. (On drives with control board versions 5.1 and greater, this will cause the AO1 connection to be empty.)
The wires that were on the terminal strip should be placed into the same positions with the exception of the wire that was in AI2. This wire can be left disconnected and placed in a condition that will not cause it to accidentally touch any metal parts or terminals.
Connect the 0-10 VDC control signal to AI2A and AI2B with AI2A as the positive terminal and AI2B as the negative terminal.

What are the dimensions and weight for the ATV31HU11M2, ATV31HU15M2, ATV31HU22M3X, ATV31H037N4, ATV31H055N4, ATV31H075N4, ATV31HU11N4, ATV31HU15N4, ATV31H075S6X or ATV31HU15S6X?

Issue:   What are the dimensions and weight for the ATV31HU11M2, ATV31HU15M2, ATV31HU22M3X, ATV31H037N4, ATV31H055N4, ATV31H075N4, ATV31HU11N4, ATV31HU15N4, ATV31H075S6X or ATV31HU15S6X?
 
Product Line:   ATV31
 
Environment:  ATV31HU11M2, ATV31HU15M2, ATV31HU22M3X, ATV31H037N4, ATV31H055N4, ATV31H075N4, ATV31HU11N4, ATV31HU15N4, ATV31H075S6X or ATV31HU15S6X
 
Cause:   
 
Resolution:   This is the size 6 and the dimensions are:
Width = 4.13 inches 105 mm
Height = 5.63 inches 143 mm
Depth = 5.91 inches 150mm
The weight is 2.92 lbs (1.35 kg)


 

Can a 9012GAR5 be used on water systems?

Issue:     
Can a 9012GAR5  be used on water systems?

Product Line:
Pressure Switches

Environment:
9012 Pressure Switches

Resolution:
Yes, all components are compatible with water systems. However, salt water may attack standard flange material and may work best with 9013F Form Q. It is important to note that these switches are control rated devices. An interposing starter, or contactor must be used for switching a pump motor . Low level signals to PLCs or computers requires the use of an interposing low level switching relay.


 

What Is The Difference Between "Mixed" and "Separate" Contact Terminals?

Issue:
What is the difference between a Zelio Plug-In relay socket with "mixed" vs. "separate" contact terminals ?

Product Line:
General Purpose Relays

Environment:
Sockets and Accessories for Zelio™ Relays

Resolution:
Sockets with "mixed" terminals have input terminals mixed together on the same side with coil terminals and are one or 2 tier design . Sockets with "separate" terminals have inputs and outputs on the same side in 2 or 3 tiers while the coil terminals are on the opposite side.

What is an ATV31****378?

Issue:  
What is an What is an ATV31****378?
 
Product Line: 
ATV31
 
Environment:
N/A

 
Cause:   N/A
 
Resolution:   
This is a special drive for Buhler Company. The 378 suffix indicates that logic input LI6 can be used as a 24vdc pulsed speed reference. Would need to obtain a replacement from Buhler Company. May also be identified as S378 suffix.

Is the 2031V66 switch 2 way compatible?

Yes, as it is based on 30 series mech with 4 terminals it is 2 way compatible.

Some of the key features are:
  • 1 gang weatherproof switch
  • Standard size gridplate and surround complete with one 30M switch
  • Vertical mount
  • 116 mm Length x 76 mm Width x 30 mm Depth
  • 84 mm apart Mounting centres

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

What is the recommended line Fuse and Circuit Breaker size for the ATV58HD79N4XZU?

Issue:   What is the recommended line Fuse and Circuit Breaker size for the ATV58HD79N4XZU?
 
Product Line:   ATV58
 
Environment:  ATV58HD79N4XZU
 
Cause:   Breaker and fuse sizing
 
Resolution:   
The recommended maximum ratings depend on how the drive is used. This is due to the fact that the rated current of the drive varies due to application requirements.

For 60 HP Constant Torque Low Noise (CTLN) and 100 HP Variable Torque (VT) applications, the recommended maximum line fuses are Class J fast acting 200 amp fuses. Class T fuses are acceptable.

For 60 HP Constant Torque Low Noise (CTLN) and 100 HP Variable Torque (VT) applications, the recommended Circuit Breaker is KAL36200 with a minimum enclosure volume of 12900 cubic inches.

For 75 HP Constant Torque (CT) and 75 HP Variable Torque Low Noise (VTLN) applications, the recommended maximum line fuses are Class J fast acting 175 amp fuses. Class T fuses are acceptable.

For 75 HP Constant Torque (CT) and 75 HP Variable Torque Low Noise (VTLN) applications, the recommended Circuit Breaker is KAL36175 with a minimum enclosure volume of 12900 cubic inches.

It is acceptable to use fuses or circuit breakers with lower current ratings.


 

Video: Installing the 225 Amp Feed-through Lug Kit into NQ Panelboards. Is there documentation for installing a feed thru lug kit?

Issue:
Does Square D offer a 225A Feed Thru Lug Kit for a NQ Panelboards? 

Product Line:
NQ Paneboards

Environment:
Application

Cause:
Ordering and Installing 

Resolution:
The NQ Panelboard does have the option for Field installation of the NQFTL2L kit,  for (30, 42 ckt) interiors and the NQFTL2H for 54, 72. and 84 ckt interiors.

NOTE:
Boxes will NOT need to be changed out to larger sizes when using a 42 ckt Main lug, or Main breaker interior. All other interiors will require a larger boxes.
See pg 9-9; Tables 9.16 and 9.17 in DIG 176 Link below for Box size changes needed


https://editiondigital.net/publication/?i=150050&p=9



Instruction Bulletin for Installation is attached 

 

What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

Issue:
Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

Product Line:
Digest 177 Section 18 : Contactors and Starters IEC

Environment:
Products sold and used in the United States

Cause:
Spacer required

Resolution:
Compensation plate catalog number GV1F03, requires 2 pieces snap together.
 

Are the lugs included with ATV61 and ATV71 drives?

Issue:
Are Lugs included with ATV61/71 drives?

Product Line:
Altivar ATV61 and ATV71 drives

Environment:
All

Cause:
Needs to know if the lugs come with the ATV61 or ATV71 drives.

Resolution:
From the installation manuals, the 61/71 products up to the HD75N4 (in 460VAC), HD45M3X (for 230VAC) and HD90Y (600VAC) include terminals. All units above that size (HD90N4, HD55M3X and HC11Y and larger) include bus bar connections. The drives with the terminals are all included in the Low Horsepower manuals, and those with bus bar connections are High Horsepower. Lugs are not included with the High Horsepower drives, and need to be supplied by the installer.

This is true for open style drives. Our enclosed drives will have lugs included.


 

Can a Molded Case switch be reverse feed or back feed?

Issue:
Are the Powerpact and Legacy molded case switches marked Line and Load?
 
Product Line:
Molded Case Switches
 
Environment:
Square D Molded Case Switches
 
Resolution:
Yes, the molded case switches have been UL tested for reverse feed applications and are not marked line and load.