2032APBL

Push Button Led 2 Gang Architrave Switch Impress

Catalogue Number: 2032APBL
2032APBL
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
  • Series 2000
  • Impress
    • Product or component type
      push-button
      Product brand
      Clipsal
      Device presentation
      basic element with full cover plate
      Actuator
      push-button
      Local signalling
      indicator light
      Fixing mode
      by screws
      Material
      plastic
      [Ue] rated operational voltage
      250 V AC
      Inrush current
      20 A
      Depth
      30 mm
      Length
      86 mm
      Width
      34 mm
      Fixing center
      70 mm
      Mounting position
      vertical
      EU RoHS Directive
      Under investigation

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the part number for a replacement cover plate for the 4062PBL?

      The part number for a replacement cover plate for the 4062PBL is - 4062PBC

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=4062PBC
      User-added image

      False Events When Using A SEL 2020/2030 and ION Enterprise

      Goals and Symptoms

      Summary

      SEL 2030 devices are used to communicate with Schweitzer Engineering Laboratories (SEL) relays. The relays only communicate with SEL proprietary protocol. The 2030 can convert this to Modbus for the use of PRODUCTS such as ION Enterprise 5.0.
      We use the name SEL 2030 but this article also applies to other modules in this product family including the SEL 2020 and SEL 2032.

      ION Enterprise 5.0 is configured to translate the Modbus data into the ION network. Within this network a Virtual ION Processor (VIP) can be used to perform logical actions based on the information obtained from the relay.

      One common action is to detect a change in state of a Boolean value. A series of VIP Setpoint modules can be configured to monitor the state of each value.  When the state changes the VIP Setpoint module records an event but can also be used to trigger an action.

      Symptoms

      The VIP Setpoint module shows repeated events without an actual change in the relay state.  This may always appear as an OFF event.

      Causes and Fixes

      Cause

      The ION Enterprise Modbus master repeatedly asks the SEL 2030 for updates.  If the SEL 2030 is providing the data directly from the port which the relay is attached to (as opposed to the port the master is attached to) then the SEL 2030 will randomly reply with Modbus exceptions. These happen when the incoming request happens at the same time as the relay is updating its information in the SEL 2030.

      These Modbus exceptions may cause a VIP Setpoint module to incorrectly register an event.

      Workaround

      There are two ways to work around this problem.

      On newer SEL 2030 devices the master port can be configured to not send exceptions when it is busy. In the port set-up configure the "BUSY_DIS" setting to "Yes" from the default "No"

      On all SEL 2030 devices you can use Memory Move commands to remap the individual relay's data into the memory used by the Modbus master. 

      Attachments

       

      • (Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/dc5af2e8c4694664c125765d001625da/fl_block_5/0.1AF2?OpenElement&FieldElemFormat=gif)

        Original article#10181

        All content © 1992-2007 Schneider Electric


      Legacy KB System (APS) Data: RESL186793 V2.0, Originally authored by KBAdPM on 07/10/2007, Last Edited by DaMi on 10/28/2009
      Related ranges: VIP, ION Enterprise V5.0, Modbus / JBus