switch 2g arch 10a 250v

Flush Switches - 2000 Series, Architrave Size, Switch 2 Gang 250V 10A

Catalogue Number: 2032A
switch 2g arch 10a 250v
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Cream 1 PCE
  • Red 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Device presentation
basic element with full cover plate and grid
Switch function
1-pole
Actuator
rocker
Number of rocker
2
Number of poles
1
Device mounting
flush
Fixing mode
by screws
Material
PC (polycarbonate)
Local signalling
without
[Ue] rated operational voltage
250 V AC
Rated current
10 A
Marking
without marking
Sustainable offer status
Green Premium product
REACh Regulation
Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Product Environmental

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Can you still get a 2033A in Desert Sand?

What is the part number for the Surround to suit a 2034A ?

The part number is a 2003/4-WE , this is the surround for both 3 and 4 gang architrave plates in the 2000 series
For more information please visit the Clipsal website on the link provided.
https://www.clipsal.com/Trade/search-results?q=2003/4
User-added image
 

Does Clipsal offer 5 gang architrave switch plate?

Unfortunately not. We do not have a 5 gang architrave switch plate. 4 gang is the biggest we make in architrave size and the part numbers are 2034A and 34A. 
For further information, please visit 
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2034A​
https://www.clipsal.com/Trade/Products/ProductDetail?catno=34A



 

What is the operating and storage temperature of the I range (iSW) switches.

There are two types of I range switch (iSW Switches) they have different properties and temperature ranges
The difference is the ISO Standard that the product is manufactured to comply with:
  • IEC/EN 60669
  • IEC/EN 60947-3
For 20-32A they comply with IEC/EN 60669
For 40-125A they comply with IEC/EN 60947-3

The operating temperature of I range switches is:-
  • For IEC/EN 60669 devices between - 20°C...+50°C without derating.
  • For IEC/EN 60947-3 devices -25...+60 °C without derating.

Their storage temperature must be:-
  • For IEC/EN 60669 devices between - 40...+100°C
  • For IEC/EN 60947-3 devices between -40...+85 °C

What is the part code for a Multi 9 circuit breaker clips

 The part code is 27052A

Is SoMachine v3.1 compatible with Windows Server 2012?

No, it is not.  Somachine v3.1 is only supported on Windows XP Pro, Windows 7 Pro 32bit, and Windows 7 Pro 64bit.

Is it Possible to Upgrade a 1600A NW16 Breaker to a 2000A NW20 by Changing the Sensor Plug.

No. It is not possible. As per the attached document the NW16 have sensor rating only from 800 - 1600A, So a 2000A Sensor Plug is not suitable for NW16 Breaker. So it can not be changed. 

What is the part number for the cover of the C2032 white

  C2032C-WE

Do you have a weatherproof cover that can be used with a C2032 plate?

Yes, the part name is 223H-WE.

 

Need a version of an XX930A1A1M12 sensor with a 2 metre range

Use a XX930A3A1M12 sensor. The range is adjustable between 203mm - 8m (use XXZPB100 to teach the sensor)

What is the dimensions for the B32A (Stainless Steel) and BB32A (Polished Brass) Architrave Switches ?

The dimensions are:
Length x 110mm
Width x 35mm
Depth x 30mm
Mounting Centres x 95mm

​Is there an alternative C-Bus Switch for 5032NL-WE?

Yes, one off 2032VH + one off 5031NMML + one off 5031NMS

What is the overload for LC1D65AU7 Contactor, when rating is 20-25A ?

17-25 Amps = LRD325
23-32 Amps =LRD332

Can i get a brushed aluminium cover plate for a C2032A?

Yes,you can get a brushed aluminium cover plate for a 2 gang architrave switch. The part number is C2002C-BA.

Do you make a 2031VHA like the 2032VHA?

Unfortunately, we only make a 2 gang version.

What is the part number for a mounting block to suit a C2033A?

Unfortunately there is no mounting block for this product.

What is the replacement for the part number 29322?

The replacement for the part number 29322 is "LV429516"

https://www.schneider-electric.com.au/en/search/LV429516
 

What is the part numbers for the covers only to suit C2000 1 gang and 2 gang switches ?

The part numbers are 1 gang - C2031C & 2 gang it is C2032C

Has the 56SW432 changed design?

No, the design and or mechanism hasn't changed since December 2002. The mechanism was changed to a seven series mechanism.

Which RS-232 cable is used for communication from PC to SCADAPack 4000 series Transmitters?

Schneider Electric 3-wire serial cable p/n TBUM297801 is used to connect from an 3-pin based RS-232 port on the SCADAPack 4000 series Transmitter (4012, 4032, 4102, 4203DR, 4203DS) to DE-9P connector on a DTE such as a PC.

What is the Pin out detail for the Modbus programming cable 110 XCA 20 3000?

The pin out details of the Modbus programming cable 110 XCA 20300 is as shown in the attached.

 

What is the replacement for the 29324?

The replacement part number for 29324 is LV429518
For further information, please visit:
https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LV429518
User-added image

What is the part number for the internal mechanism that actuates the snap switch in a 9002AW2 foot switch?

Issue:
Replaceable internal mechanism of 9002AW2 foot switch

Product Line:
Foot Switches

Environment:
9002A Heavy Duty Industrial

Resolution:
Not available as a repair part.

Will changing the cover on the C2032V66 affect the IP rating ?

Changing the Cover ( C2032C ) does not affect IP rating as long as mechs not changed

For more information regarding this product please visit the Clipsal web site on the link provided

https://www.clipsal.com/Trade/search-results?q=c2032v66

Application of 17-18, 20-21 Contacts in the UA Controller (P/No. 29472)

They are the additional control contacts for the external signals, where 

20-21 Contact ("Replacement" source voltage contact) This can be controlled by a specific test on the "Replacement" source. Transfer to "Replacement" source occurs only if the the test passed and the contact is closed. 
For example: This contact can be used to test the frequency of the "Replacement" source voltage. Transfer to the "Replacement" source will only take place if the test result is within tolerances.

17-18 Contact: (Voluntary transfer) An external signal can be used to initiate transfer to the "Replacement" source. The load returns to the "Normal" source when the signal is cleared

Attached document for reference. 

How to correct error 22321 Liquid:Calculation of Density at base conditions unsuccessful in Realflo?

Scenario:
  • The scadapack is polling values from the Coriolis Meter.
  • When the Coriolis Meter losses connections or it stop communicating, The Realflo Run liquid will use the default setting parameters.
  • Make sure that correct parameters are entered on the Default value.
For example: If the default value for the Density was set to 1 when measuring Liquid and the Coriolis meter losses communications then
the flow computer will used the default value 1 to calculate the flow and will give an error result of 22321 "Liquid:Calculation of Density at base conditions unsuccessful"

Use the table below for Density default value:

Is my 6600A part of the product from the recall circa 2002?

Both Schneider Electric and Gerard Corporation make a bathroom unit called the 6600A.
This was a recall by Chief Kitchenware which was/is a part of the Gerard Corporation.
Clipsal and Schneider Electric have no responsibilities to this recall.

For further information please see the link below.
https://www.recalls.gov.au/content/index.phtml/itemId/954606



 

What is the part number for surround to suit 2030?

The surround to suit 2030 architrave is part number 2001.

Some of the key features are:
  • 1 gang
  • Architrave
  • Curved side

For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2001

 

What is the part number for a Brass cover for the classic range 2 gang switch - C2032VA?

The part number for a Brass cover for the classic range 2 gang switch - C2032VA is - C2032C-BS

For further information visit link below:-
https://www.clipsal.com/Trade/search-results?q=C2032C-BS
User-added image

We want to upgrade coprocessor firmware with OSLoader. What ports on firewalls should be allowed for successful firmware download and upgrade?

The Port 20,21 and 502 of PLC should be enabled in firewall to access the Quantum and M580 during FW upgrade. 
Security settings of Quantum Coprocessor and M580 should be enabled to allow the firmware upgrade in Unity application. 
 

Does StruxureWare Power Monitoring (SPM) 7.0.1 support Windows Server 2012 and SQL Server 2012?

SPM 7..0.1 does not support Windows Server 2012 or SQL Server 2012.


Legacy KB System (APS) Data: RESL211178 V1.0, Originally authored by MaTh on 04/10/2013, Last Edited by MaTh on 04/10/2013
Related ranges: Power Monitoring 7.0

Video: How to assemble the XB4 illuminated multicap?

You can find in attachment a video showing the procedure to assemble them :

https://youtu.be/Ye6lr3gN8EA

PowerLogic System Display (SD700) for Power Server, 63230-216-221A1, September 2002.

See attached document:
63230-216-221A1.pdf

  • Last Revised: 26/7/2007

    Public

    All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL198191 V1.0, Originally authored by KBAdPM on 04/01/2009, Last Edited by KBAdPM on 04/01/2009
Related ranges: PowerServer

Video: What is the default grid snap setting in Vijeo Designer v6.2?

The default spacing is 20x20 pixels.  It can also be changed from the Graphical Panels Properties.

The following video demonstrates adjusting the grid snap spacing in Vijeo Designer via the Graphical Panels Property Inspector.

 

Setting up a Write_VAR function block in a M340 to write to SDOs in a CAN device.

Goals and Symptoms

M340, CANopen, Write_Var

Causes and Fixes


First your project Configuration and double click on the CAN port to configure it



Configure the CAN port as needed for your application and notice the Channel # of the CAN port (Channel 2)
Note: The Inputs & Outputs configured here are for PDOs not SDOs.



Next open the CANopen Network from the Configuration. Double click on the Node to add a CAN device.



From the available list chose the CAN device you will be using and press OK.
For this example we are using a Altivar 71 drive.



A picture of the device will appear on the network. Double click in the Node box to adjust the Node ID of the device.
Then double click on the device for its configuration.



Configure the CAN Device as needed.
Note: PDOs are memory mapped directly to memory locations within the M340 SDOs are not.



Next open the Project Settings and configure them so that you can directly address arrays in your program.
This step is optional however if you do not do this you will need to declare variables as array's in you program.



Next open you program section and add a ADDM block (for addressing the CAN device) and a
Read_Var block.

The ADDM block for CAN has an input syntax of r.m.c.e (rack.module.channel.equipment) and is
entered as a string so a ' is needed before and after the string. The OUT pin is connected directly to the
ADR pin of the Read_Var.

The remaining parameters of the WRITE_VAR are configured as follow:

OBJ (object type we are reading, string input)
NUM (location in the CAN device we are reading from. Subindex_index for CAN)
NB (length of read in words)
EMIS (location array in the M340 where the information to be written is stored)
GEST (Array of 4 INTs used for the Write Manager Exchange)

In this Example we are writing a value from %MW110 of the M340 to the ACC Acceleration
at Subindex 0002 (hex) and Index 2032 (hex) in the Altivar drive.

Before you can download this to you PLC there is one additional step required.
For CANopen writes to SDOs from a Write_Var block a timeout value and transmission length
need to be configured in the Write Manager Exchange array.

Open the Variable Declaration editor declare variables for the 4 INTs in the Write Manager Exchange array.
The third and fourth INTs are for the timeout value (in tenths of a second) and the transmission length (in Bytes).

In our example we are writing 1 word so the length is 2 bytes.



Finally Build/Download your project and Run the PLC.


What is the 25-32A overload to suit the 56MS400?

Overloads and parts are no longer available for the 56MS range, these have been replaced with the 56DOL range, neither of which would handle 32A.
The largest 56DOL starter is rated at 16A and the 12-18A overload is LRD21.
If a 32A DOL starter is required selct from the LE1D range, the LE1D35 has a 15kW 32A rated contactor in it to which an LRD32 23 - 32A overload can be fitted.
 

What is the part number for the Relay and RPO connector for the Conext CL inverters?

One set of dry contact Relay and RPO connectors are provided along with the wiring box packaging.
The Relay and RPO connector is included in a plastic bag with other connectors, if it is lost, you will have to purchase another one.
The part number is 0J-0L2344 (Lit Kit IEC CL 20/25 kw Rohs package)

M251 boot up time

Issue:
What's the M251 boot up time?

Product Line:
M251

Resolution:
According to the validation lab, it takes around 20-25 seconds for the M251 to start. 
It could take up to 30 seconds with applications where a lot of code is called. 

Does the L5504RVF have it's own power supply?

Yes it has a 200mA power supply..
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=L5504RVF
User-added image
 

What is the difference between Windows Server 2008 R2 and Windows Server 2012?

A lot of functions were added in the newer Win Server OS, some examples below:
· No more Std and Ent SKU, all Win Server 2012 SKUs are with functions like Ent SKU, and Win Server 2008 R2 only supports Std functions.
· Win Server 2008 R2 is without Hyper V, Win Server 2012 default supports Hyper V.
· …

You may check attached file for further details comparison between Win Server 2008 R2 and Win Server 2012.

What is the coil consumption or burden for the Tesys LC*D** contactors?

Issue:
What is the coil consumption or burden for the Tesys LC*D** contactors?

Product Line:
Tesys Contactors and Overload Relays

Environment:
All Products

Cause:
Product Features

Resolution:
All AC coils for the LC1D40 through LC1D80 3 or 4-pole contactors have an inrush of 200VA for 50 Hertz applications or 220VA for 60Hz.
Sealed values are 20VA for 50 Hertz applications or 22VA for 60 Hertz applications. For 50/60 Hertz coil inrush is 245VA and sealed is 26VA


CTA-ID : 2029994

Can Concept error '801 - error opening loadable file' be corrected?

Cause:
    Concept is unable to locate a loadable in the Concept \DAT folder when doing a compare or download.

Resolution:
    Make sure the loadable used in the project resides on the "Installed" side of the Configure - Loadables section of the Configurator.

    If not, move if from the "Available" column on the left to the "Installed" column on the right.

    If it is not "Available", hit the <Unpack> button and point to the loadable's .EXE or .DAT file and <Unpack> it.  It will then
    show up in the "Available" column and can be "Installed".

    Make sure that all user loadables needed in the project are in the Concept \DAT folder.
    

What are the cradle rejection (cell keying) kits for NT/NW circuit breakers?

Issue:
What are the cradle rejection (cell keying) kits for NT/NW circuit breakers?

Product Line:
Circuit Breakers

Environment:
Masterpact NT and NW

Resolution:
Cell keying kits are standard, however the field installable kits are S33767 for NT, NWCELLKEY for NW.

NW cell keying history:
Cell Keying Kit for W/Y-frame (pins of varying lengths)  All production after December 2012:   NWCELLKEY

Older part numbers:
S48562C was developed to provide complete mismatch protection. It is used on breakers and boards assembled in Columbia. This has been replaced with NWCELLKEY.
The S48562 kit has pins all the same length and is from France. It has gaps in protection against mismatch. It was sold to OEM`s.

What are the contact ratings of the 9001 BG***, BW***, and BR*** control stations?

 
Product Line:
9001BG, 9001BW, 9001BR, control stations, 30MM

Environment:
9001 Control Stations

Resolution:
They are rated NEMA B600 for AC and NEMA P600 for DC. This is 5 amps continuous and 600 volts maximum. They don`t have horsepower ratings so they are not rated for direct motor starting duty.
 
CTA-ID : 2007833

How to power a Xantrex System Control Panel when no XW+ or SW is present?

When using a Xantrex System Control Panel, this unit is powered from either an XW+ or an SW hybrid inverter.

When in a situation that either one of these hybrid inverters are not available, to get the SCP to operate, you will need to provide an independant 15V DC 200mA supply to the Xanbus network.

+ve should be connected straight to pins 1,2 and 7. -ve should be connected to 3, 6 and 8.

Do you have a energy or power monitor available?

Yes, the part number is EM422EM-E-KMTS.
Some of its key features are:

  • Mains Operated
  • Frequency: 433.5 MHz
  • Transmission Time: 6s. 12s. or 18s
  • Transmission Range: 40 m
  • Voltage Range: 110V-400 V
  • Measuring Current: 50mA-95A
  • Accuracy: ≥ 50mA but ≤ 200 mA: ± 80% at 25 deg C, > 200mA but ≤ 20A: ± 90% at 25 deg C, > 20A but ≤ 90A: ± 95%


For futher information please see attachment.

Or visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=EM422EM-E-KMTS


 

What is the part number for a 8 channel leading edge C-Bus dimmer?

The part number for a 8 channel leading edge C-BUS dimmer is L5508D1A.
Some of the key features are:
  • 8 channel Leading Edge
  • 12M DIN modules wide
  • 8 channels of 1A rating
  • suitable for incandescent and low voltage lighting
  • software selectable network burden and C-Bus system clock
  • inbuilt 200mA C-Bus power supply
  • C-Bus Learn Enabled
  • Single Phase
  • Connection: 2 x RJ45 sockets
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=L5508D1A


 

What is the difference between L5508RVFP and L5508RVF?

L5508RVFP and L5508RVF are C-Bus DIN Rail Mounted Relay Units, 250V AC 10A 8 Channel, 12M modules wide. The only difference between the two is L5508RVFP does not come with C-Bus Power Supply and L5508RVF is with 200mA C-Bus internal Power Supply.
For further information, please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5508RVFP
https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5508RVF

User-added image
User-added image

What is the replacement for the CentaMeter?

The replacement for the centameter is the CPLEM422EM-E-KMTS.

Key Features

  • Battery Operated
  • Frequency: 433.5 MHz
  • Transmission Time: 6s. 12s. or 18s
  • Transmission Range: 40 m
  • Voltage Range: 110V-400 V
  • Measuring Current: 50mA-95A
  • Accuracy: ≥ 50mA but ≤ 200 mA: ± 80% at 25 deg C, > 200mA but ≤ 20A: ± 90% at 25 deg C, > 20A but ≤ 90A: ± 95%

What is the maximum current that can be delivered from the internal 24 volt power supply on Lexium 28?

The internal 24 volt power supply can provide a maximum of 200ma at 24vdc (available at pin 17 of the 50 pin signal connector CN1)
This 24 volt source is provided as a means to supply I/O switches and or proximity switches that are connected to the inputs of LXM28


Rev 8-1-18
 
Show More