swt 1gang horiz 10a ip66

Flush Switch, 1 Gang, 250VAC, 10A, Series 2000, Weatherproof, Horizontal, IP66

Catalogue Number: 2031H66
swt 1gang horiz 10a ip66
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Cream 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Device presentation
basic element with full cover plate
Switch function
  • 2-way
  • 1-way
    • Actuator
      rocker
      Number of rocker
      1
      Device mounting
      flush
      Fixing mode
      by screws
      Material
      PC (polycarbonate)
      Local signalling
      without
      [Ue] rated operational voltage
      250 V AC
      Rated current
    • 10 A
    • 10 AX, fluorescent lamp
      • Marking
        without marking
        Sustainable offer status
        Green Premium product
        REACh Regulation
        Reference contains Substances of Very High Concern above the threshold
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN
        Circularity Profile
        N/A

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • CAD Files and Packs

        • Technical Data Catalogues

        • Installation Instruction

        • Product Environmental

        • Operating Manuals

        • Specifications

        • Certificates (MSDS)

        Frequently Asked Questions

        hide show

        Can part number 30M35 be used in 2031V66?

        No. Unfortunately, part number 30M35 CANNOT be used in 2031V66.

         

        Does the 2031V66 come in architrave?

        No it doesnt

        What IP66 rating weather proof indoor switches are there avaliable?

        The IP66 rated weather proof indoor switches avaliable are 2031V66, C2031V66.

        Do you do the 2031V66 with double pole switches?

        No, the 2031V66 does not have double pole mechanisms.

        Some of the key features are:
        • Switches have been re-designed to provide mechanisms that can be re-orientated horizontally or vertically
        • 1 gang weatherproof switch

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

        Can the grid for the 2031v66 be purchased without mechs?

        No, We do not supply or encourage this as the 2031v66 has a specific gasket set up to ensure weatherproof rating and this may be compromised if tampered with therefore we only sell them assembled.

        What is the mech that fits in the 2031V66 switch?

        Unfortunately we dont do the mech as a spare part it is essentually a 30 mech with a rubber seal between the contacts ant the dolly and we dont do that mech as a spare part.

        Is the 2000 Series or C2000 IP66 Rated?

        No, unfortunately 2000 series products are not IP66 Rated.
        However, we do offer a very limited range in the C2000 and 2000 series that are IP66 rated.
        The items are as follows:
        Cat No. Description
        2031V66 Single switch for vertical mounting - 2000 Series
        2031H66 Single switch for horizontal mounting - 2000 Series
        2032V66 Twin switch for vertical mounting - 2000 Series
        2032H66 Twin switch for horizontal mounting - 2000 Series
        C2031V66 Single switch for vertical mounting - C2000 Classic
        C2031H66 Single switch for horizontal mounting - C2000 Classic
        C2032V66 Twin switch for vertical mounting - C2000 Classic
        C2032H66 Twin switch for horizontal mounting - C2000 Classic
        C2031V66IC Identifi cation kit + cover for C2031V66 - C2000 Classic
        C2031H66IC Identifi cation kit + cover for C2031H66 - C2000 Classic
        C2032V66IC Identifi cation kit + cover for C2032V66 - C2000 Classic
        C2032H66IC Identifi cation kit + cover for C2032H66 - C2000 Classic
        Some of there key features are:
        • 1 or 2 gang weatherproof switch
        • 84 mm apart Mounting centres
        • Switches have been re-designed to provide mechanisms that can be re-orientated horizontally or vertically

        See attached document for the catalogue on these products.

        For furter information please visit https://www.clipsal.com/Trade

         

        Do you do a C2031V66 in a 3 gang?

        No unfortunately we only go up to 2 gang (C2032V66)

        Are mechs only available for part number C2031V66?

        No. Unfortunately, Mechs only are not available for switch.

        Is gasket only available for part number 2031V66?

        The gasket is not available for this part

        for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

        User-added image

        What is the part number of a red lens for the ZB4BW643?

        Issue:
        What is the part number of a  red lens for the ZB4BW643?

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Cause:
        Product selection

        Resolution:
        The Lens only for the ZB4BW643 is not a replacement part.


         

        What is the recommended line reactor part number for ATV31HD11S6X?

        Issue:   What is the recommended line reactor part number for ATV31HD11S6X?
         
        Product Line:   ATV31
         
        Environment:  ATV31HD11S6X
         
        Cause:   Line reactor
         
        Resolution:   
        RL01802.


         

        Is the 2031V66 switch 2 way compatible?

        Yes, as it is based on 30 series mech with 4 terminals it is 2 way compatible.

        Some of the key features are:
        • 1 gang weatherproof switch
        • Standard size gridplate and surround complete with one 30M switch
        • Vertical mount
        • 116 mm Length x 76 mm Width x 30 mm Depth
        • 84 mm apart Mounting centres

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031V66

        Do you do the C2031V66 weather proof switch in intermediate?

        Unfortunately this part is unavailable. As an alternative you could use the WS226I, however it is a different range and looks entirely different. 

        Some of the key features are:
        • 1 gang
        • M100 rating
        • Weather protected switch
        • Outdoor lighting, Illuminated signs applications
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=WS226I​

         

        What is the part number for a replacement ID window for the C2031HI?

        The part number for a replacement ID window for the C2031HI is - 30PID-2

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=30PID-2

        Can I get the gasket for a 2031H66-WE seperately?

        No, the gasket is not sold seperately. 

        Do you make a 2031VHA like the 2032VHA?

        Unfortunately, we only make a 2 gang version.

        What is the white cover plate for a 2031VCS

        The part code is 2000-WE surround cover plate

        How long is the cable that comes with the 2032HWS?

        That cable is 1.8m long.

        What is the part number for a 20amp mech to go in to the C2031V66?

        No. Unfortunately, there are no 20 amp mech available for this range.

        What coil codes are available for the U-Line motor starter Control Units?

        The coil codes available for the U-Line Motor Starter control units are as follows:
        24VDC is BL
        24VAC is B
        48-72V DC or 48V AC is ES
        110-240V AC/DC is FU.
        We do not have 480VAC coils available


        CTA-ID : 2031577

        Will the LA4DC1U work with the new CAD32BD relay?

        Issue:
        Will the LA4DC1U work on the CAd32BD relay

        Product Line:
        IEC relays and accessories

        Environment:
        Products sold and used in the United States

        Cause:
        Identifying product compatibility

        Resolution:
        The CAD32BD with DC coil has built-in coil suppression protection as standard so the LA4DC1U is not needed.


        CTA-ID : 2031917

        What does the 9001SKY302 consist of?

        Issue:
        What does the 9001SKY302 consist of?

        Product Line:
        Push Buttons

        Environment:
        30mm Pushbuttons

        Cause:

        Resolution:




        The 9001SKY302 consists of:
        (1) 9001SKY3 enclosure, ((2) 9001SKR1B operators, (1) 9001SKR3R operator, (2) 9001KA1 contact blocks, (1) 9001KA3 contact block, (1) 9001KN111WP UP legend plate, (1) 9001KN110WP DOWN legend plate, and (1) 9001KN102RP STOP legend plate.


        CTA-ID : 2061576

        What is the wattage loss of the ATV31HU75N4?

        Issue:   What is the wattage loss of the ATV31HU75N4?
         
        Product Line:   ATV31
         
        Environment:  ATV31HU75N4
         
        Cause:   Watts dissipated
         
        Resolution:   
        269 Watts at full load


         

        What is the recommended line reactor part number for ATV31HU75S6X?

        Issue:   What is the recommended line reactor part number for ATV31HU75S6X?
         
        Product Line:   ATV31
         
        Environment:  ATV31HU75S6X
         
        Cause:   Line reactor
         
        Resolution:   
        RL01202.


         

        What is the recommended line reactor part number for ATV31HU55S6X?

        Issue:   What is the recommended line reactor part number for ATV31HU55S6X?
         
        Product Line:   ATV31
         
        Environment:  ATV31HU55S6X
         
        Cause:   Line reactor
         
        Resolution:   
        RL00802.


         

        What is the mounting height of a PowerPact H Frame 3-pole breaker

        Product Line:
        Circuit Breakers
        PowerPact H
        I Line

        Environment:
        Electrical Distribution Equipment

        Resolution:
        It takes 4.5`` of mounting height.
         

        What is the parts breakdown of a 9001KP1R31?

        Issue:
        9001KP1R31 components

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Resolution:
        It consists of a 9001KM1 light module, 9001KP operator and a 9001R31 lens.

        Will changing the cover on the C2032V66 affect the IP rating ?

        Changing the Cover ( C2032C ) does not affect IP rating as long as mechs not changed

        For more information regarding this product please visit the Clipsal web site on the link provided

        https://www.clipsal.com/Trade/search-results?q=c2032v66

        What LED`s can be used in a 22mm direct supply light module like a ZB2BV6?

        Issue:
        What LED`s can be used in a 22mm direct supply light module like a ZB2BV6?

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Cause:
        Product selection

        Resolution:
        Any BA9 bayonnet style LED. We offer the following:

        6 volt DL1CJUS0063 green 12 volt DL1CJUS0123 green
        6 volt DL1CJUS0064 red 12 volt DL1CJUS0124 red
        6 volt DL1CJUS0065 amber 12 volt DL1CJUS0125 amber

        24 volt DL1CJUS0243 green 120 volt DL1CJUS1203 green 24 volt DL1CJUS0244 red 120 volt DL1CJUS1204 red
        24 volt DL1CJUS0245 amber 120 volt DL1CJUS1205 amber




        CTA-ID : 2012660

        Will a ZB4BVG3 pilot light module work with a ZB4BV03 pilot light head?

        Issue:
        Will a ZB4BVG3 pilot light module work with a ZB4BV03 pilot light head?

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Cause:
        Product Features

        Resolution:
        No. The ZB4BVG3 are for use with protected LED pilot light heads only. The ZB4BV03 is for a BA9 base lamp and will not fit the ZB4BVG3.
        The following pilot light heads will work with the ZB4BVG3:
        White ZB4BV013
        Green ZB4BV033
        Red ZB4BV043
        Yellow ZB4BV053
        Blue ZB4BV063.

        For fresnel (jeweled) lenses, use:
        White ZB4BV013S
        Green ZB4BV033S
        Red ZB4BV043S
        Amber ZB4BV053S
        Blue ZB4BV063S.



        CTA-ID : 2043466

        Where is the Service Entrance Label located on the main breaker/main lug NF merchandise panel?

        Issue:
        Location of ULSE label

        Product Line:
        Panelboards

        Environment:
        NF

        Cause:
        Rating

        Resolution:
        Service Entrance statement is on the 80041-613-07` label ( separate from the torque label) located on the back of the interior deadfront.

        What is the part number for the locking handle used on QM-WP enclosures?

        Issue:
        Replacement N3R handle

        Product Line:
        Panelboards

        Environment:
        QMB

        Cause:
        Maintenance

        Resolution:
        All QM style WP enclosures require (1) 80121-063-50 locking handle assembly.
         

        What is the replacement for the CA3DK22BD?

        Issue:
        What is the replacement for the CA3DK22BD?

        Product Line:
        Relays and Timers

        Environment:
        Obsolete Products

        Cause:
        Legacy Replacement

        Resolution:
        The CA3DK is Obsolete. To electrically replace it, use a CAD32BD & a LAD6K10B
         

        Will the 9013G pressure switches accept stranded wire?

        Issue:
        Will the 9013G pressure switches accept stranded wire?

        Product Line:
        Type G—Pumptrol Pressure Switch

        Environment:
        Commercial Pressure Switches

        Resolution:
        9013G will accept stranded wire.

        What is the ampere rating for dc voltages for the 9001KA contact blocks?

        Issue:
        DC ampere rating for 9001KA contact blocks

        Product Line:
        Harmony Push Buttons

        Environment:
        Harmony 30mm

        Cause:
        Product Features

        Resolution:
        2.5A continuous up to moved. (NEMA Q600)

        Can the Micrologic FFTK (Full Function Test Kit) be repaired?

        Product Line:
        Micrologic test equipment

        Environment:
        Electrical Distribution Equipment

        Resolution:
        Yes, the FFTK can be repaired in most cases. Have the distributor contact Customer Service for a "Return for Repair" RMA and send it back.
        (see internal FA289579)

         

        What is the inrush/current draw of the shunt trip coil MG26974? It is a 24VAC shunt trip for a C60N Merlin Gerin breaker.

        Product Line:
        Circuit Breakers
        M9

        Environment:
        Electrical Distribution Equipment

        Resolution:
        That unit has a momentary draw of 120 W.
         

        What is the difference between the GV2MC01 and the GV2MC02 enclosures?

        Product Line:
         
        GV Manual Motor Starters and Protectors
         
        Resolution:
        The GV2MC01 has an IP41 rating ( similar to Nema Type 1 ), whereas the GV2MC02 has an IP55 rating (similar to the Nema Type 12 ).

         

        How many LUFN auxiliary blocks may be installed on a U-line starter?

        Issue:
        What is the quantity of LUFN auxiliary blocks, that  may be installed on a U-line starter?

        Product Line:
        PTCTR - Contactors

        Environment:
        Tesys U-line

        Resolution:
        Just one LUFN** or function module per starter.


         

        Is a 9001BR103 momentary or maintained?

        Issue:
        Is a 9001BR103 momentary or maintained?
        Product Line:
        30mm Control Station
        Environment:
        9001 Standard Duty Control Stations
        Cause:
        Action of operator needs to be known for an application.                              
        Resolution:                                                                 
        The action of the operator is momentary.
         

        What is the mounting hole diameter of a 30mm pushbutton?

        Issue:
        What size is the mounting hole for a 9001KX  30mm pushbutton?

        Product Line:
        Pushbuttons and Operator Interface

        Environment:
        9001K, 9001SK and 900KX 

        Cause:
        Product Features

        Resolution:
        31 mm or 1.22 inches.

        Are the Multi 9 circuit breakers and supplementary protectors considered "trip free"?

        Issue:
        Are the Multi-9 style breakers trip free?

        Product Line:
        Miniature Circuit Breakers

        Resolution:
        "Trip Free" means the breaker will trip in an overcurrent situation even if the handle is locked in the "on" position. These breakers are considered trip free.

        What is the accuracy of the KWH or MWH power meter for the ATV58 type drives?

        Issue:   What is the accuracy of the KWH or MWH power meter for the ATV58 type drives?
         
        Product Line:   ATV58
         
        Environment:  All
         
        Cause:   KHW MWH accuracy
         
        Resolution:   
        The kW and kWH measurements have +/- 5% accuracy.
        The drive calculates the kW and kWH rather than making actual power measurements to the motor.
        Information provided by the PLE (Product Line Engineer), Chuck Cudlipp.


         

        What is the difference between a molded case vs an insulated case breaker?

        Product Line:
        Circuit Breakers

        Environment:
        Electrical Distribution Equipment

        Resolution:
        An insulated case circuit breaker is a molded case circuit breaker with an integral 2-step stored-energy mechanism. They have the functionality of an iron-frame breaker, or a low-voltage-power breaker with a molded plastic instead of an iron frame.
         

        Does the XALK194 E-stop control station have a maintained contact?

        Issue:
        Does the XALK194 E-stop control station have a maintained contact?
        Product Line:
        22mm Control Stations and Enclosures                   
        Environment:
        XAL 22MM Control Stations
        Cause:
        Clarify if the operator or contact block is maintained.       
        Resolution:                                                                 
        The contact is momentary, but the operator is a maintained push pull mushroom button. This will hold the contact open when the button is depressed.
         

        Where are the overload relays for use with LC2D reversing contactors?

        Issue:
        Identifying the appropriate overload relay to use with a reversing pair of contactors

        Product Line:
        Digest 177 Section 18 : Contactors and Starters - IEC

        Environment:
        North American Products

        Cause:
        Overload relay needed for use in reversing application

        Resolution:
        Reversing contactors use the same overload relays as non-reversing contactors.


         

        Will the XALD control station push button operators accept boots?

        Issue:
        Available boots for XALD control station push button operators.

        Product Line:
        Harmony Control Stations

        Environment:
        All Products

        Cause:
        Product Features

        Resolution:
        Yes, clear boots are available for pushbuttons with circular heads. They are available in neoprene using catalog number ZBP0. For use in the food and beverage industry, they are available in silicone using catalog number ZBP0A.

        What was a Unitized EZ Stack meter center?

        Issue:
        Product Features

        Product Line:
        Unitized EZ Metering Equipment

        Resolution:
        The Unitized EZ Stack devices were self-contained meter centers, available with up to six disconnecting means. The 100 ampere devices accepted field installed Type QO or Q1 tenant breakers. The 125 ampere and 150 ampere devices were supplied with factory installed Type Q2 tenant breakers. This product line is obsolete. The current offering for this application would be MP METER-PAK.


         

        What is the difference between a QO and QOB breaker?

        Issue:

        What is the difference between a QO and QOB breaker?

        Product Line:

        QO and QOB

        Environment:
        Electrical Distribution Systems

        Resolution:
        A QO breaker is plug on mounting, and can be used in QO load centers, old NQO and NQOD panelboards, and current NQ panelboards. A QOB breaker uses a bolt-on connection to the bus, and can be used in old NQOB and NQOD panelboards, and current NQ panelboards. Otherwise the breakers are the same.