socket auto switched 20a

Socket Auto Switched 20A

Catalogue Number: 2010/20
socket auto switched 20a
Colour: White Electric
Colour: Per UOM Std.
  • Cream 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Quantity per set
set of 1
Cover type
full cover plate
Marking
without marking
Local signalling
without light indicator
Device mounting
flush
Fixing mode
by screws
Material
PVC (polyvinyl chloride)
Surface finish
glossy
[In] rated current
20 A
[Ue] rated operational voltage
250 V AC
Depth
31 mm
Length
116 mm
Width
76 mm
Fixing center
84 mm
Number of poles
1
Standards
  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133:approval number S/1
    • Sustainable offer status
      Green Premium product
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the plaster bracket to suit the 2000/2?

      The part number for the plaster bracket to suit the 2000/2 is 2155PRM/2.

      What is the cover for a C2015/20?

      The cover for a C2015/20 is a C2015/20C.

      Is part number C2015/20 available in Red?

      Yes it is and the part number is C2015/20-RD.

      What is the part number of Mounting bracket for a 2000/2?

      The part number for a for a mounting bracket for a 2000/2 is 2154/2.

      Some of the key features are:
      • Mounting brackets
      • 2 gang
      • For plaster board or hardboard mounting for wall boards up to 12 mm thick

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2154/2
       

      Do Clipsal make a 3 pin, 20 amp, switched outlet with flat pins?

      Yes, 20A 3 flat pin switched outlets are available in a few variants , most commonly the 2015/20, C2015/20 and 56C320F.

      For further information please visit:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015/20
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015/20
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56C320F

       

      What is part number for Stainless Steel cover to suit C2015/20?

      The part number for Stainless Steel cover to suit is a C2015/20C.

      What is the material of the cover for a 9013GHG2 made of?

      Product Line:
      Pumptrol pressure switches, Class 9013

      Resolution:
      Noryl SE-1X is used on 9013G devices for the cover, and on 9013F products with 3R rating.


      CTA-ID : 2010510

      Can I order the 220/20 in white?

      Yes, you can order the 220/20 in white but it needs to be done as a special.
      For more information, please refer to the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=220/20

      Are there double GPO's that are individually wired on each side?

      Yes, there are a few GPO's that are individually wired, they are C2016/2, 16/2MF, 2015/2V and 15/2V. In a weather proof option we have the WSC227/1/2

      What is the maximum voltage rating of the Wiggy voltage tester.

      Issue:
      Application

      Product Line:
      Wiggy Voltage Tester

      Cause:
      Clarifying maximum voltage

      Resolution:
      600 volts AC, 250 volts DC maximum.


      CTA-ID : 2010590

      What is the part number for wall plate for 2000/2?

      The part number for metal wall plate 2000/2  will be  2155PRM2.

       

      Do you have a cap/ flange to for 20mm conduit?

      Yes the part number is 221/20

      Looking to replace the LXM23DU04M3X and BCH0602O12A1C

      Issue:
      Looking to replace the LXM23DU04M3X and BCH0602O12A1C servo motor

      Product Line:
      LXM23

      Resolution:

      The direct replacement is:
       
      LXM28AU04M3X and BCH2LD0431CA5C combination:
       
      - Supply voltage single phase 200/240 VAC or 3 phase 200/240 VAC, 50/ 60 Hz
      - Nominal torque 1.27 Nm
      - Maximum peak torque 3.81 Nm
      - Nominal speed 3000 RPM
      - 0.4 Kw motor rating
      - 0.27 kgcm2 motor inertia without holding brake
       
      You cannot copy the parameters from the old drive to the new drive. They will have to be entered manually in the new LXM28 drive.

      Is Silver color on part 2000/2 same as Brushed Aluminium?

      The Silver color is shinier than Brushed Aluminium and is distinctly different

      for information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000/2

      User-added image

      What is the part number of an autoswitched 250V 15A single switched power outlet?

      2010/15 and 10D15S are autoswitched 250V 15A single switched power outlet. For further information, please visit

      2010/15
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2010/15 


      10D15S
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=10D15S

      Latest Firmware version of Com'X 200/210 and Natively supported device type in the Energy Server Com'X 200/210

      Product Line
      COM'X200 / EBX200
      COM'X210 / EBX210
       
      Environment
      Ethernet Gateway supported devices
       
      Resolution
      The latest version of firmware for Com'X 200 is 3.5.15 and the Com'X 210 is 4.0.10. Please find the firmware files below.
      They can be downloaded from the following links as well.
      COM'X200 firmware
      COM'X210 firmware
       
      In addition, review the attached PDF (DeviceList_ComX200_210_2.2.1.pdf) for the list of Natively Supported Device Types on Com'X 200/210 with Firmware Version 2.2.1.
      Note: With firmware 3.5.24, the Com'X 210 also supports Masterpact MTZ and the EM4399.

      For instructions on how to upgrade the firmware, view article FA270261.

      Can you get a plate larger than 6 gang in the 2000 series?

      Not directly, but using the 2000/2 or 2000h2 series you can fit 2 plates under one surround.

      Are the Clipsal Conduit Clips available in Electric Orange?

      No, they are only available in grey.

      This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

      What is the cut out for the C2016/2?

      The cut out for the C2016/2 is 30mm (H) X 200mm (W).

      What do I have to add to the ATV28 to make it NEMA Type 1

      Issue:   What do I have to add to the ATV28 to make it NEMA Type 1
       
      Product Line:   ATV28
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:  
      By using the grey adhesive cover supplied with the drive from the factory and adding the Conduit Enterance Kit you will achieve a Type 1 rating.


       

      What are the dimensions for part number C2016/2?

      The dimensions for part number C2016/2 are:
      159mm (L)  47mm (H) 28mm (D)

      What is the mounting centres for part number C2016/2?

      Mounting centres for part number C2016/2 are 122mm.

      Do we still have any 4013/40 globes available?

      No longer  available

      What are the measurements for a C2016/2?

      The measurements for the C2016/2 are 48mm (H) x 160mm (W) x 28mm (D) with a mounting centre of 122mm 

      What is part number for mounting block to suit C2016/2?

      Unfortunately, No mounting block available.

      Can you get a 2000/2 in chrome.

      This part  only comes in standard 'bakelite' colours. Please visit the below link to our website for more information and colour options.
      Today, the 2000 series is clipsal’s most popular product range and its surrounds are available in a wide choice from single gang standard size versions to multigang surrounds for situations where you want to house up to four gridplates in a single surround. 2000 series flush surrounds feature a design that neatly conceals all mounting holes, a durable high gloss finish for easy cleaning and a clever clip on/clip off design that enables surrounds to be easily removed when redecorating to conceal overpainting or untidy cut marks when wallpapering.
      Please see following link for more details and colour choices of multi gang range.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000/2

      Is the 801/20R retractable lead still available?

      This retractable lead is no longer in our product range and there is no alternative available.

      Do we have a replacement for retractable cabel reel 801/20R?

      No. Unfortunately, 801/20R is discontinued and there is no replacement.

      Com'X 200 / 210 / 510 Documentation (Technical Datasheet, User Guide, and Installation Guide)

      Issue
      Documentation for COM'X 200/210/510 is needed

      Product Line
      Com'X 200 (EBX200)
      Com'X 210 (EGX210)
      Com'X 510 (EBX510)

      Environment
      Documentation

      Resolution
      The documents below include Technical Datasheet, User Manual, and Installation Guide

      Com'X 200/210/510 Installation Guide:5406AD002
      Com'X 200/210 User Manual: DOCA0036EN
      Com'X 510 User Manual: DOCA0098EN
      Com'X 200/210/510 Technical Datasheet: PLSED310098EN
       

      Is the dimensions for a Clipsal C2016/2-WE the same as C2016/2S

       No, the C2000 is 48mm x 160mm x 28mm  with 122 mounting centres

      What is the rating of the PDL675 shaver outlet?

      The PDL675 shaver outlet is rated 20VA @110/230 volts.

      What are the part numbers of slip type expansion couplings?

      Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
      16mm = 251/16
      20mm = 251/20 *
      25mm = 251/25 *
      32mm = 251/32
      40mm = 251/40 *
      * = only available in Grey
      Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
      Dimension details are attached.
       

      What are the dimension for the 2000H2?

      The dimension for the 2000H2 are - H232mm x W 76mm x D13mm

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=2000H2
      User-added image

      What is the wall box to suit a Clipsal C2016/2

      Not available

      In the 600 Series, is the 691/15 available in RED

      Not available, but Clipsal 2015/15 is available in red but it's horizontal.

      Can the FTX117 hand held programmer be used for off-line program development of a TSX07 Nano PLC?

      Yes; however in order to use the FTX117 for off-line development the user must have both an optional power supply and an optional PCMCIA memory card for the FTX117.
      Two models of power supply were offered:

      • TFTXADC11 (110/120 VAC)
      • TFTXADC12 (200/240 VAC)
      Three models of PCMCIA cards were offered:
      • TFTXREM3216 (EEPROM 32K)
      • TFTXRSM3216 (Protected RAM 32K)
      • TFTXRSM12816 (Protected RAM 128K)
      None of these items are still actively sold. If the user would like off-line programming capability with the FTX117 and currently does not already have both a power supply and a PCMCIA card for it they should contact SERVICE.SALES@US.SCHNEIDER-ELECTRIC.COM for sales information on these items.

      What is part number for 4 gang 2000 series surround?

      The part number for 4 gang 2000 series surround 2000/4.

      Is there any bracket available for a 2000/4?

      There is no stud bracket, you could use the 2154/4 mounting clip.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2154/4

      Will the XVBC11 tulip fit with XVBL beacons?

      Issue:
      Will the XVBC11 tulip fit with  XVBL beacons?

      Product Line:
      Harmony Tower Lights

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      Yes, the XVBC11 tulip base will work with XVBL beacons when used with a support tube.


      CTA-ID : 2011190

      Can a 9013FS ``water switch`` be used on an air compressor load ?

      Yes ....as long as the switch meets the pressure range requirements . The switches designed for water pressure, as a group, will have a lower range of pressures. Note that a pressure relief valve, which is often desired for compressor loads , is not available with 9013FS products


      CTA-ID : 2023020

      What is the difference between CA2KN and CA3KN?

      Issue:
      What is the difference between CA2KN and CA3KN?

      Product Line:
      Relays and Timer

      Environment:
      All products

      Cause:
      Product features

      Resolution:
      CA2 has AC coil. CA3 has DC coil.


      CTA-ID : 2050650

      What is the part number for the solid state overload relay for 185 amps for LC1F185G7?

      Product Line:
       
      Tesys F line Contactors

      Resolution:
       
      The LR9F5371 has a setting range of 132-220 amps. The interconnection kit LA7F407 is required to directly mount the overload to the contactor.


      CTA-ID : 2060527

      Is part number C2016/2 available in vertical?

      Unfortunately, Part number C2016/2 is not available in Vertical.

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2016/2


      User-added image

      Does the Com'X 200/210 or Com'X 510 support the Powerlogic and SY/MAX protocols?

      Issue
      A user needs to know if the Com'X 200 / Com'X 210 / Com'X 510 supports the Powerlogic and SY/MAX protocols

      Product Line
      Com'X 200/EBX200
      Com'X 210/EBX210
      Com'X 510/EBX510

      Environment
      Gateway Portocol Support

      Cause
      A user needs to convert legacy device protocols such as Powerlogic and SY/MAX from CM2000 series, CM200 series, CM100 series, etc. to Modbus TCP/IP.

      Resolution
      The Com'X 200, Com'X 210 and Com'X 510 do not support the Powerlogic or SY/MAX protocols.
      Use an EGX100 or EGX300 to convert Powerlogic or SY/MAX to Modbus TCP/IP. However, EGX100/300 have been obsoleted and the replacement is EGX150. EGX150 supports the Powerlogic or SY/MAX protocols as well.

      Com'X 200 supported Protocols:
      IPv4
      IPv6 - HTTP
      HTTPS
      Modbus TCP/IP

      Com'X 510 supported Protocols:
      HTTP
      HTTPS
      FTP
      SMTP
      Modubs TCP/IP

      Video: How to Reset the Web page Password to factory values for Com'x 200/210 and 510?

      Issue
      If the web-page password is lost, user would like to reset the password to factory default values. 

      Product Line
      Com'x 200, Com'x 210, Com'x 510

      Cause
      User has lost their password to login into web-page of Com'x gateway and they would like to reset password to default values.

      Resolution
      If the web-page password is lost, follow the procedure below in order to reset the password to factory default values: 
      1. Press the Backup button (number 7 shown in screen shot below) on the Com'x 200 (or 510) from front panel and hold it for 10 seconds until the power LED flashes green 3 times.
      2. Release the button. 
      3. To access to the Com'x configuration web pages, use these settings: 
                           Username: admin
                           Password: admin



      What is the part number for a Contactor with Low consumption?

      The part number for a low consumption contactor is LC1D09.
      General Product information:
      Range of product TeSys D
      Product or component type Contactor
      Device short name LC1D
      Contactor application Motor control Resistive load
      Utilisation category AC-1, AC-3
      Poles description 3P
      Power pole contact composition 3 NO
      [Ue] rated operational voltage <= 300 V DC for power circuit
      <= 690 V AC 25...400 Hz for power circuit
      [Ie] rated operational current 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
      25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
      Motor power kW 5.5 kW at 660...690 V AC 50/60 Hz
      5.5 kW at 500 V AC 50/60 Hz
      4 kW at 415...440 V AC 50/60 Hz
      4 kW at 380...400 V AC 50/60 Hz
      2.2 kW at 220...230 V AC 50/60 Hz
      Motor power HP (UL / CSA) 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
      5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
      2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
      2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
      1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
      0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
      Control circuit type AC 50/60 Hz
      Control circuit voltage 415 V AC 50/60 Hz
      Auxiliary contact composition 1 NO + 1 NC
      [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
      Overvoltage category III
      [Ith] conventional free air thermal current 10 A at <= 60 °C for signalling circuit
      25 A at <= 60 °C for power circuit



      For more information please visit https://www.schneider-electric.com.au/en/productcontaLC1D



      Why will LA1SK11 adder deck not fit on CA2SK11 relay?

      Issue:
      Why will LA1SK11 adder deck not fit on CA2SK11 relay?

      Product Line:
      Tesys Relays

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      No, LA1SK11 mounts only on the CA2SK20 relay.




      CTA-ID : 2014524

      Do the DC operated 3 pole D-LINE Tesys contactors come with surge suppression as standard?

      Issue:
      Do the DC operated 3 pole D-LINE Tesys contactors come with surge suppression as standard?

      Product Line:
      D line contactors.

      Environment:
      Products sold in the United States.

      Cause:
      Product features.

      Resolution:
      The LC1D09 - D32 contactors with DC coils come with coil suppression as standard


      CTA-ID : 2049420

      What is the correct socket for the RUW101MW timer relay?

      Issue:
      What is the correct socket for the RUW101MW timer relay?

      Product Line:
      Zelio Relays

      Environment:
      All products

      Cause:
      Product Selection

      Resolution:
      This timer relay will work on either the RPZF3 or the RPZF4 socket with the RPM relays.   It will also work in any of the RUMC or RUMF relay sockets, RUZC or RUZF.


      CTA-ID : 2060390

      How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

      Issue:
      Implementing a hardwire stepdown transformer in a 208v or 240v environment


      Product Line:

      Smart-UPS / Symmetra

      Environment:

      APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

      Cause:

      Unbalanced UPS outputs require a stepdown transformer to power 120v loads


      Resolution:

      This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

      The wiring block outputs are as follows:


      For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

      The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



       Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

      Show More