socket swt auto sing 15a 250v

Automatic Single Switch Socket Outlet, 250VAC, 15A

Catalogue Number: 2010/15
socket swt auto sing 15a 250v
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Quantity per set
set of 1
Local signalling
without light indicator
[In] rated current
15 A
[Ue] rated operational voltage
250 V AC
Depth
31 mm
Length
116 mm
Width
76 mm
Fixing center
84 mm
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • Sustainable offer status
      Green Premium product
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      In the 600 Series, is the 691/15 available in RED

      Not available, but Clipsal 2015/15 is available in red but it's horizontal.

      What is the part number of an autoswitched 250V 15A single switched power outlet?

      2010/15 and 10D15S are autoswitched 250V 15A single switched power outlet. For further information, please visit

      2010/15
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2010/15 


      10D15S
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=10D15S

      Is there a double pole 15A outlet?

      Yes, the part number is a 2015D15

      What is part no for 15amp vertical single GPO

      PART NO 2015V15

      What is the material of the cover for a 9013GHG2 made of?

      Product Line:
      Pumptrol pressure switches, Class 9013

      Resolution:
      Noryl SE-1X is used on 9013G devices for the cover, and on 9013F products with 3R rating.


      CTA-ID : 2010510

      What is part number for cover to suit C2015/15?

      Part number for cover to suit is C2015C.

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015C


      User-added image

      What are the part number for a 15 amp outlet with RCD protection?

      Not available as 1 unit. Would have to use 2015/15 with 2031VRCD30
      For further information , visit links below:-
      https://www.clipsal.com/Trade/search-results?q=2015/15
      https://www.clipsal.com/Trade/search-results?q=2031VRCD30
      User-added image
      User-added image

      What is the part number for a replacement for 15/15/EL30?

      There is no direct replacement for this unit. Customer would be able to use 3 items to make this up - 2015/15 , 2031RC30 & 2000H2

      For further information , visit links below:-
      https://www.clipsal.com/Trade/search-results?q=2015/15
      https://www.clipsal.com/Trade/search-results?q=2031RC30
      https://www.clipsal.com/Trade/search-results?q=2000H2
      User-added image

      User-added image
      User-added image

      What is the replacement part number for the SCR module for ATS23C15N or ATS23C24N?

      Issue:   What is the replacement part number for the SCR module for ATS23C15N or ATS23C24N?
       
      Product Line:   ATS23
       
      Environment:  ATS23C15N ATS23C24N
       
      Cause:   N/A
       
      Resolution:   No parts available replace starter



       

      What is the plaster bracket to suit the 2000/2?

      The part number for the plaster bracket to suit the 2000/2 is 2155PRM/2.

      What is the threaded plug to suit clipsal SS15/15

      PDL56P315

      XY2CH: What is the replacement contact block for this switch?

      The contacts cannot be replaced.

      What are the Square D part numbers for the fans used internal to the ATV66D33N4U?

      Issue:
      What are the Square D part numbers for the fans used internal to the  ATV66D33N4U?
       
      Product Line:
      ATV66
       
      Environment:
      Fans
       
      Cause:
      n/a 

      Resolution:
      Each of these drives have the VZ3V665 heat sink fan which is the larger fan located in the bottom of the unit. The NMB part number for this fan is 5915PC-23T-B30.
      Each of these drives have the VZ3V6654 power board stirring fan which is a small fan located in the upper left side of the unit.
      Only the ATV66D54N4U, ATV66D64N4U, ATV66D79N4U and ATV66D46M2U drives also have a VZ3V6655 capacitor bank fan located above the power terminal block.

      These drives are the Frame Size 4 and Frame Size 5 ATV66.

      The part numbers are listed on page 98 (page 104 in Adobe Acrobat) of the VD0C06S304E Receiving, Installation and Sart Up manual in Appendix A - Spare parts list.  The part # for the fans of the other size units is also listed in this table.


       

      What are the part numbers for a suspension socket with a switch

      Part numbers are SS15 or SS15/15

      What is another option for a 15A version of the PDL 927P ?

      Could use the Clipsal SS15/15 with PDL 56P315

      What is the parts breakdown of a 9001KYK120?

      It consists of a a 9001KY1 and a 9001KP1R31.


      CTA-ID : 2050065.

      What is part number for 4 gang 2000 series surround?

      The part number for 4 gang 2000 series surround 2000/4.

      Is there any bracket available for a 2000/4?

      There is no stud bracket, you could use the 2154/4 mounting clip.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2154/4

      What is the maximum voltage rating of the Wiggy voltage tester.

      Issue:
      Application

      Product Line:
      Wiggy Voltage Tester

      Cause:
      Clarifying maximum voltage

      Resolution:
      600 volts AC, 250 volts DC maximum.


      CTA-ID : 2010590

      What is the part number for wall plate for 2000/2?

      The part number for metal wall plate 2000/2  will be  2155PRM2.

       

      My meter is measuring 0A and 0kW but correctly reads the Voltage, what is the issue?

      Product Line
      ION Meters

      Environment
      Installation/Setup

      Resolution
      If the meter is being provided a very small current (0.005A/5mA or less) on the secondary side, the meter will read 0 for the phase current.
      Since kW is dependent on the current reading this value will also be zero.

      To find out what the minimum Primary starting current is you can calculate as follows:
      Primary_Min_Current = 0.005 * CT_Ratio
      Where CT_Ratio = CT_Primary/CT_Secondary

      Example:
      CT Ratio = 2000:5 (Primary:Secondary)
      Starting Current = 0.005A (Secondary)

      CT_Ratio = 2000/5 = 400
      Primary_Min_Current > 0.005 * 400 = 2A (primary side load).

       

      What is the part number of Mounting bracket for a 2000/2?

      The part number for a for a mounting bracket for a 2000/2 is 2154/2.

      Some of the key features are:
      • Mounting brackets
      • 2 gang
      • For plaster board or hardboard mounting for wall boards up to 12 mm thick

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2154/2
       

      What is the Zelio relay SR1*201BD scan frequency?

      Issue:
      What is the Zelio relay SR1*201BD scan frequency?

      Product Line:
      Zelio Relays and Timers

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      The cycle time is 8ms and has a response time of 14 - 26ms.


      CTA-ID : 2012071

      Is Ethernet communication available on ATS48 or ATS22 solid state softstarts?

      Issue:
      Is Ethernet communication available on ATS48 or ATS22 solid state softstarts?

      Product Line:
      ATS22, ATS48

      Environment:
      All

      Cause:
      NA

      Resolution:
      Yes, via the TSXETG100 or TSX100SD (it has High temperature range 70 deg C) Ethernet bridge. Please be aware that you cannot do I/O scanning on the ATS48 or the ATS22 softstarter.

      CTA-ID : 2051085

      What type of fuse does RM17TE00 except?

      Issue:
      What type of fuse does RM17TE00 except?

      Product Line:
      Zelio Relays and Timers

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      Correct fuse is a 1 A fast acting CC or gG fuse on the input.  There was a error in the instructions.


      CTA-ID : 2061041

      What is the difference between an LAL36250MB and a regular LAL36250?

      Product Line:
      Legacy Circuit Breakers

      Environment:
      Electrical Distribution Equipment

      Resolution:
      The MB breaker has a shorter handle, so that it will not interfere with the door closing on a panel.
       

      Is the ATV28 HU29N4U rated NEMA 1?

      Issue:   Is the ATV28 drive rated NEMA 1?
       
      Product Line:   ATV28
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:   No. It is an open style drive that requires an enclosure.


       

      Does the C2025D15 have separate feeds for each side ?

      No - 1 feed for both.

      For more information on this range please visit the Clipsal.com web site on the link provided
      https://www.clipsal.com/Trade/search-results?q=c2025d15

      Are there double GPO's that are individually wired on each side?

      Yes, there are a few GPO's that are individually wired, they are C2016/2, 16/2MF, 2015/2V and 15/2V. In a weather proof option we have the WSC227/1/2

      Does the ATV28 unit have MOVs on the line side?

      Issue:Does the ATV28 unit have MOVs on the line side?
       
      Product Line: ATV28
       
      Environment: All
       
      Cause: N/A
       
      Resolution: No.


       

      FCL Current Transformers

      Issue
      Customer needs split-core CT with an amperage rating greater than 2400 A

      Product Line
      Model FCL Current Transformers

      Environment
      Current Transformers

      Resolution
      Model FCL Current Transformers have current ratios from 200/5 to 6000/5 A. They are a split-core type current transformer.

      Please find cutsheet for Model FCL Current Transformers attached. 

       For quotes for FCL CTs please contact sales.

      Why is the drive not responding to the 4-20mA feedback signal when the Pump Switching Card is installed?

      Most common issue is Parameter o19 must be set to the maximum pressure of the sensor in Bars.  Parameter o20 is set to the PI setpoint in Bars.

      To get the pressure in Bars, divide the pressure in PSI by 14.504.


      CTA-ID : 2015151

      What is the part number for the locking handle used on QM-WP enclosures?

      Issue:
      Replacement N3R handle

      Product Line:
      Panelboards

      Environment:
      QMB

      Cause:
      Maintenance

      Resolution:
      All QM style WP enclosures require (1) 80121-063-50 locking handle assembly.
       

      Is the 8660 AlphaPak soft starter repairable?

      Product Line: 8660 AlphaPak SSRVS


      Environment:All 8660 class AlphaPak starters


      Cause:N/A


      Resolution: The 8660 AlphaPak starters are obsolete. There are no parts available, and are no longer repairable.

      At what frequency can you get nominal torque from the ATV28 drive?

      Issue:   At what frequency can you get nominal torque from the ATV28 drive?
       
      Product Line:   ATV28
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:   You can get nominal motor torque at 1 Hz.


       

      What the current specifications for the 24vdc internal supply on the ATV28?

      Issue:   What the current specifications for the 24vdc internal supply on the ATV28?
       
      Product Line:   ATV28
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:   Customer current available is 100mA.
      The +24v is protected against short-circuits and overloads, min. 19v, max. 30 V. Max.


       

      Where can you find basic wiring schematics for the ATS01 soft starter?

      Issue:
      Is there information available on wiring for the ATS01 soft starter?
       
      Product Line:
      Altistart ATS01
       
      Environment:
      All
       
      Cause:
      ATS01 wiring information
       
      Resolution:
      You can find ATS01 wiring diagram information in catalog 8637CT0401.

      What is the part number for the Cooling Fan for the ATS46 softstarter


      Issue:Cooling Fan part number
      Environment: Replacement parts
      Cause: Cooling fan failure.
      Resolution: See attached document for heat sink cooling fan part numbers.

      What is the part number for the conduit entry kit for the ATV31HU55M3X, ATV31HU75M3X, ATV31HU55N4, ATV31HU75N4, ATV31HU55S6X, ATV31HU75S6X?

      Issue:   What is the part number for the conduit entry kit for the ATV31HU55M3X, ATV31HU75M3X, ATV31HU55N4, ATV31HU75N4, ATV31HU55S6X, ATV31HU75S6X?
       
      Product Line:   ATV31
       
      Environment:  ATV31HU55M3X, ATV31HU75M3X, ATV31HU55N4, ATV31HU75N4, ATV31HU55S6X, ATV31HU75S6X
       
      Cause:   N1 conduit kit selection
       
      Resolution:   
      VW3A31816


       

      Do we have explosion proof start-stop control stations?

      Issue:
      Do we have explosion proof start-stop control stations?
      Product Line:
      30mm Control Stations and Enclosures                   
      Environment:
      9001B Standard Duty Control Stations
      Cause:
      Verifying that Schneider Electric has an offering for this application.           
      Resolution:
      The 9001BR control station are rated Nema 7 and 9 for hazardous locations.

      Which enclosures can the GV2E01 sealing kit be used on?

      Issue:
      Which enclosures can the GV2E01 sealing kit be used on?

      Product Line:
      IEC Manual Starters/Protectors - GIC Product

      Environment:
      US Product

      Cause:
      Product Application

      Resolution:
      GV2MC01 and GV2MP01.

      What is a ZBG455P?

      Issue:
      What is a  ZBG455P?

      Product Line:
      Harmony Push Buttons

      Environment:
      22mm pushs buttons

      Cause:
      Product composition

      Resolution:
      A set of 2 Ronis 455 keys, one of which is booted (rubber boot).


       

      Can you wire R2 relay on the ATV28 drive to a 115Vac light?

      Issue:   Can you wire R2 relay on the ATV28 drive to a 115Vac light?
       
      Product Line:   ATV28
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:   Yes. The R2 relay contacts are rated for 1.5A 250Vac and 30Vdc.


       

      What is the part number for a single switched socket, 15A with extra switch?

      C2015/15X is the part number for a single switched socket, 15A with the extra switch.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=C2015/15X

       

      Does Clipsal have a 15 amp GPO with an extra switch?

      Yes, we have the C2015/15X from the Classic range.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/search-results?q=c2015/15X

      Latest Firmware version of Com'X 200/210 and Natively supported device type in the Energy Server Com'X 200/210

      Product Line
      COM'X200 / EBX200
      COM'X210 / EBX210
       
      Environment
      Ethernet Gateway supported devices
       
      Resolution
      The latest version of firmware for Com'X 200 is 3.5.15 and the Com'X 210 is 4.0.10. Please find the firmware files below.
      They can be downloaded from the following links as well.
      COM'X200 firmware
      COM'X210 firmware
       
      In addition, review the attached PDF (DeviceList_ComX200_210_2.2.1.pdf) for the list of Natively Supported Device Types on Com'X 200/210 with Firmware Version 2.2.1.
      Note: With firmware 3.5.24, the Com'X 210 also supports Masterpact MTZ and the EM4399.

      For instructions on how to upgrade the firmware, view article FA270261.

      How to change the display settings of energy units from MWh to kWh in ME Meter.

      Depending on the ME meter version, meter will automatically select the appropriate units and therefore it is not possible to modify the energy units. From 40/5 to 150/5 CT ratio, the energy unit display is KWh and from 200/5 to 6000/5 CT ratio, the energy unit display is MWh.

      CT Setting:
      To change the CT settings hold down the button on the Front Face of the ME Meter for more than 5 sec when on the CT Rating display. After approximately 5 sec the display will start blinking, now enter the CT setting. Once again hold the button till the display stop flashing, to ensure that the entry is saved.

      Are Masterpact NW and NT circuit breakers 100% Rated?

      Issue:
      Are Masterpact circuit breakers 100% Rated?

      Product Line:
      Masterpact NT and NW

      Environment:
      NEMA influenced markets only

      Resolution:
      All UL 489 listed Masterpact NT and NW circuit breakers are 100% rated.
      Note that standard 80% vs. 100% rating applies to breakers listed per UL 489 only.
       

      What is the part number for the Heatsink thermal switch for ATS46 softstarter?

      Issue: Heatsink thermal switch part number
      Environment: Replacement parts
      Cause: Thermal switch  failure.
      Resolution: See attached document for HS Thermal switch part numbers. Note: All are obsolete with no replacement. Replace starter with new ATS48.

      What is the ohmic value and average power for the resistor used in the VW3A66713 dynamic brake kit?

      Issue:
      What is the ohmic value and average power for the resistor used in the VW3A66713 dynamic brake kit?

      Product Line:
      Salivary Drives

      Environment:
      All

      Cause:
      DNA

      Resolution:
      The value is  of the resistor is 28 ohms and the power is 204 watts.
      Show More