Clipsal 2000 Series Flush Surround 2 Gang, Curved Sided

White Electric | Clipsal 2000 Series Flush Surround 2 Gang, Curved Sided

Clipsal 2000 Series Flush Surround 2 Gang, Curved Sided

Item Number: 2002-WE

Retail
$17.41
RRP (Inc. GST)

For vertical spaces, the Clipsal 2000 Single Switch Socket brings you safe, reliable power. Rated 15A, 250V, the outlet is suitable for use with heavier duty appliances. The neon indicator lets you know from a distance, or in the dark, when power to the outlet is activated.

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-
Surround
Surrounds

Specifications

Design

Range of product

  • Gangbusters
  • Series 2000
    • Product brand

      Clipsal

      Sustainable offer status

      Green Premium product

      Physical

      Mounting position

      vertical

      Device mounting

      flush

      Type of installation

      indoor

      Depth

      11 mm

      Length

      86 mm

      Width

      34 mm

      REACh Regulation

      Reference contains Substances of Very High Concern above the threshold

      EU RoHS Directive

      Pro-active compliance (Product out of EU RoHS legal scope)

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120506EN

      Material

      Material

      PVC (polyvinyl chloride)

      Others

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      0.013 kg

      Package 1 Height

      11 mm

      Package 1 width

      34 mm

      Package 1 Length

      86 mm

      Unit Type of Package 2

      BB1

      Number of Units in Package 2

      10

      Package 2 Weight

      0.13 kg

      Package 2 Height

      70 mm

      Package 2 width

      91 mm

      Package 2 Length

      117 mm

      Unit Type of Package 3

      CAR

      Number of Units in Package 3

      150

      Package 3 Weight

      1.95 kg

      Package 3 Height

      237 mm

      Package 3 width

      203 mm

      Package 3 Length

      300 mm
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Product Environmental

      Frequently Asked Questions

      hide show

      What is the wattage rating for Clipsal 501ES

      It is 200w for white ones

      What ramifications would there be if a drive or soft start is powered on with 200 volts at 400 Hz?

      Issue:
      Line power is 200v at 400 hz.

      Product Line:
      All drives and soft starts

      Environment:
      All models and serial numbers

      Cause:
      None

      Resolution:
      The EMC filter caps that are line to line may draw too much current. If the drive has SCR rectifier for softstart, they may not work above 60 Hz. DC bus capacitors have not been evaluated for 400 Hz power.

      Is my 6600A part of the product from the recall circa 2002?

      Both Schneider Electric and Gerard Corporation make a bathroom unit called the 6600A.
      This was a recall by Chief Kitchenware which was/is a part of the Gerard Corporation.
      Clipsal and Schneider Electric have no responsibilities to this recall.

      For further information please see the link below.
      https://www.recalls.gov.au/content/index.phtml/itemId/954606



       

      What is the 2000 series blank plate

       The part code 2031VX-WE

      Can I plug my APC Rack-Mount Power Distribution Unit (Rack PDU) into a feed receptacle located in the under floor plenum? (Also applicable to Configurable & Modular Power Distribution)


      Yes, provided the installation conforms to NFPA 70 the National Electric Code requirements as stated in Article 645 Information technology equipment.

      With the 2008 Edition (and subsequently the 2011 Edition), Article 645.5 clearly states that cord-and-plug connections and certain cable types are allowed under raised floors, provided certain conditions are met. Following are excerpts from the 2008 Edition of the Code. Refer to the complete section of the applicable edition of the NEC for your locality.
       

      645.5 Supply Circuits and Interconnecting Cables

      (B) Cord-and-Plug Connections. The data processing system shall be permitted to be connected to a branch circuit by any of the following listed means:
       

      (1) Flexible cord and attachment plug cap not to exceed 4.5 m (15 ft).

      (2) Cord set assembly, where run on the surface of the floor, shall be protected against physical damage.
       

      (D) Under Raised Floors. Power cables, communications cables, connecting cables, interconnecting cables, cord-and-plug connections, and receptacles associated with the information technology equipment shall be permitted under a raised floor, provided the following conditions are met:
       

      (1) The raised floor is of suitable construction, and the area under the floor is accessible.

      (2) The branch-circuit supply conductors to receptacles or field-wired equipment are in rigid metal conduit, rigid nonmetallic conduit, intermediate metal conduit, electrical metallic tubing, electrical nonmetallic tubing, metal wireway, nonmetallic wireway, surface metal raceway with metal cover, nonmetallic surface raceway, flexible metal conduit, liquidtight flexible metal conduit, or liquidtight flexible nonmetallic conduit, Type MI cable, Type MC cable, or Type AC cable. These supply conductors shall be installed in accordance with the requirements of 300.11.

      (3) Supply cords of listed information technology equipment in accordance with 645.5(B).

      (6) "Cables," shall be listed as Type DP. Type DP cable having adequate fire resistant characteristics suitable for use under raised floors of an information technology equipment room.


      Rack Power Distribution

      All of APC's Rack PDUs are UL Listed and as such meet all requirements for NEC 645 ITE data center installations. Prior to the 2008 Edition of the NEC, cord-and-plug connections under the raised floor were not explicitly identified in the 2005 Edition of the Code. However, based on the following code sections, these cord-and-plug connections of APC Rack PDUs are acceptable. 1) per 645.4(3) the equipment is UL Listed 2) per 645.5(B)(1) the flexible cord and attachment plug cap do not exceed 15 ft. 3) per 645.5(D)(2) branch-circuit supply conductors to receptacles are properly installed in accordance with 300.11 4) 645.5(D)(5) specifically relates to "cables" used under the raised floor, and not "flexible cord" as is the IT equipment power cord.


      Making Power Connections to Rack PDUs Using Flexible Conduit

      Some installations use wiring in flexible conduit (i.e. Sealtite) that is directly attached to a mating connector body for making the power connection to Rack PDUs. Any US installation must use methods that conform to NFPA 70 Article 300.

      For 50A Rack PDUs that have CS8365 Hubbell style connector, Hubbell has a mating Pro-series connector body that can be attached directly to flexible conduit fittings. We recommend using a Hubbell Pro connector (CS8364L) with a 1/2" (H050) or 3/4" (H075) seal tight connector.


      Configurable and Modular Power Distribution

      Power cables from APC Configurable and Modular Power Distribution units are Type DP-1 TC-ER tray cable and per 645.5(D)(6) and Table 645-5 are allowed under raised floors.
       

       

       



       

      What is the ATS22 adjustable range for ILt, current limit?

      Issue:
      Current Limit range for ILT on ATS22.

      Product Line:
      ATS22

      Environment:
      All models

      Cause:
      N/A

      Resolution:

      The range is 200% to 700% of parameter In, motor rated current.  The maximum is limited to 350% of the ATS22 amp rating.
      If the application requires more than 350% of ATS22 rating, then the soft starter must be up sized.


       
      Show More
      Office

      Range

      The contemporary styling and flexibility of the 2000 Series and C2000 range have made it Clipsal’s most popular range of switches and power points.

      2000 Series and C2000 range offers a range of stylish switches in standard and architrave sizes. Power points are available in single, double and automatic models, in vertical or horizontal format, with options such as neons, extra switches and safety shutters. The extensive product range also includes dimmers, fan speed controllers, timers, weatherproof switches and TV, data and phone sockets.