cover pvc 1g t/setter surr

Flush SurRound, 1 Gang, Horizontal Mount, Standard Pattern TrEndsetter

Catalogue Number: 2000T
cover pvc 1g t/setter surr
Colour: White Electric
Colour: Per UOM Std.
  • Cream 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Mounting position
horizontal
Device mounting
flush
Material
PVC (polyvinyl chloride)
Type of installation
indoor
Depth
13 mm
Length
116 mm
Width
76 mm
Sustainable offer status
Green Premium product
REACh Regulation
Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Product Environmental

  • Installation Instruction

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Is it Possible to Upgrade a 1600A NW16 Breaker to a 2000A NW20 by Changing the Sensor Plug.

No. It is not possible. As per the attached document the NW16 have sensor rating only from 800 - 1600A, So a 2000A Sensor Plug is not suitable for NW16 Breaker. So it can not be changed. 

What is the part number for an LED flood light that has 20000 Lumens output?

The part number for an LED flood light that has 20000 Lumens output is - FLH200LED

For further information , visit link below:-
User-added image
https://www.clipsal.com/Trade/search-results?q=FLH200LED
 

How do I get Modsoft to open up to full screen display while I try to run it under WIN 2000?

The command to get Modsoft to change window size is ALT+<ENTER>; however Modsoft is not supported under WIN 2000. Users may try running the application under it; however successful operation cannot be guaranteed. One of the common problems is Modsoft will not open up to full screen. Regrettably there is no means to resolve this issue other than to reinstall the software under a supported OS, such as WIN 95, WIN 98 or DOS.


Legacy KB System (APS) Data: RESL171500 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modsoft

Can you get a double power point with 2 USB ports?

No, unfortunately this part is unabaliable. However, there is a single power point with 2 USB ports avaliable. This is avaliable in two diffrent styles, 2000 Series or the Classic 2000 Series. The part numbers are (Classic 2000) C2015USB2C and (2000 Series) 2015USB2C.
Some of there key features are:
  • Twin 30USBCM USB Chargers
  • Surge, over-current and over-temperature protection
  • Cable compensation for optimised charging
  • Meets BC1.2 USB Charging Standard
  • Meets Class V Energy Efficiency in standby
  • Certified to all relevant safety and EMC requirements for Australia

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015USB2C
                                              Or https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015USB2C

 
 
 

 

Can you get a plate larger than 6 gang in the 2000 series?

Not directly, but using the 2000/2 or 2000h2 series you can fit 2 plates under one surround.

Starting Register number in Modbus Read functions

Goals and Symptoms

When performing Modbus read commands, it is important to apply the right starting register address in the read function. Otherwise, the wrong register will be accessed from the meter, giving unexpected data for the meter parameter being read.


  • Meter is functioning as expected. The front panel values for voltages and currents are within expected ranges for the system being monitored. However, modbus read functions from a master station (e.g. a PLC) give values that do not correspond to the front panel values.

Facts and Changes

Modbus, modbus rtu, function read, modbus map, holding register, staring register, function 03, modbus read packet

Causes and Fixes

Cause
One probable cause would be that, the modbus function read command is not pointing to the right registers. The modbus protocol requires an offset to be introduced in the starting register address when reading the slaves register.

Resolution

When reading the meter parameters, the Master must send the device a Read Holding Registers packet. This packet must specify a start register and the number of registers to read. When the function read is received, the slave responds with a packet containing the registers in the range defined in the read request.

However, consider the 3710 Modbus map, which states that according to the MODBUS protocol, in response to a request for address 4xxxx, the master reads register xxxx-1 from the slave (3710). For example, a request for register 40011 returns register 10 from the slave.

What does the above statement mean? Why is an offset required?

Holding registers, by default, are defined the 4xxxx range, the first holding register staring at 40001. The starting register in the read packet is, on the other hand, numbered from zero. Hence, the start register zero automatically points to holding register 40001, starting register one points to holding register 40002, etc. The fact that the first holding register is 40001 and not 40000 explains the offset that needs to be introduced in the starting register number.

Hence, considering the 3710 Modbus Map statement, if the Master needs to read register 40011, then the corresponding starting register that needs to be put in the read function would be 10 (0A hex) since register 40011 is the register 10 from the first holding register, 40001:
40001 > Start register 0
40002 > Start register 1
40003 > Start register 2
40004 > Start register 3
40005 > Start register 4
40006 > Start register 5
40007 > Start register 6
40008 > Start register 7
40009 > Start register 8
40010 > Start register 9
40011 > Start register 10

The Modbus Read Request Packet for a master reading 3 registers from a slave with unit ID 100 (64 Hex) and for starting register of 40011 should be:
 

Slave ID
Function
Start Register (40011)
# of Registers
CRC Checksum
64
03
00
0A
00032C3C


To summarize, when looking at a modbus map, the starting register number to be used in the read function:

Start Register = Modbus Register 40001.

 

Original article#12774

Public

All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL188799 V1.0, Originally authored by KBAdPM on 11/03/2007, Last Edited by KBAdPM on 11/03/2007
Related ranges: Modbus / JBus

Sepam EcoFit offer

Schneider Electric offers a retrofit solution for converting Sepam 2000's to the new Sepam 1000+ relays.
ECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT SEPAM 2000 Customer Presentation Rev1a.pptECOFIT SEPAM 2000 Customer Presentation Rev1a.ppt

Is Event Notification Solution 6.4 /Active Pager Module 6.4 (ENS 6.4, APM 6.4) compatible with SQL 2000?

ENS 6.4 is only supported with SQL 2005 and SQL 2008 instances.
During the install, SQL 2000 instances can be chosen, but the install will not complete if a SQL 2000 instance is selected.


Legacy KB System (APS) Data: RESL206608 V1.0, Originally authored by MaTh on 11/09/2011, Last Edited by MaTh on 11/09/2011
Related ranges: Paging Module, SMS Add-on

What is the Pin out detail for the Modbus programming cable 110 XCA 20 3000?

The pin out details of the Modbus programming cable 110 XCA 20300 is as shown in the attached.

 

Is cut out for Modena/Strato same as C2000?

Yes, same dimensions as C2000 series.

What are the placement considerations for the condenser relative to the InRow ACRD10x?

Issue:
What are the placement considerations for the condenser relative to the InRow ACRD10x?

Product line:
ACRD100, ACRD101

Environment:
Data Center Cooling

Cause:

Resolution:
The condenser should always be placed above the InRow ACRD10x unit at a distance not to exceed 200ft equivalent pipe length.

 

What version of SQL Server is used with the different versions of ION Enterprise?

ION Enterprise 3.0 MSDE 1.0 (SQL Server 7.0)
ION Enterprise 4.0 MSDE 1.0 (SQL Server 7.0)

ION Enterprise 4.5 MSDE 1.0 (SQL Server 7.0)

ION Enterprise 5.0 MSDE 2000 (SQL Server 2000)

ION Enterprise 5.5 MSDE 2000 (SQL Server 2000)

NOTE: It is possible to use ION Enterprise 5.5 Service Pack 2 with SQL Server 2005, but some modifications are required. See KB articles 12704, 12708 and 12823 for detailed information.

ION Enterprise 5.6 SQL 2005 Express (SQL Server 2005)
NOTE: ION Enterprise 5.6 will use an existing MSDE 2000 instance, but will install SQL Express on new systems if there is no pre-existing SQL Server instance.
ION Enterprise 6.0 SQL 2005 Express with Reporting Services SP3 (SQL Server 2005 SP3 with Reporting Services)
NOTES: The ION Enterprise 6.0 installer will upgrade an existing MSDE 2000 instance to SQL Server 2005 Express with Reporting Services. ION Enterprise 6.0 does not support SQL Server 2000. It also does not support SQL Server 2008

  • Original article#16492

    Public

    All content © 1992-2009 Schneider Electric


Legacy KB System (APS) Data: RESL188782 V3.0, Originally authored by KBAdPM on 11/02/2007, Last Edited by JaMc on 10/15/2009
Related ranges: ION Enterprise V5.5, ION Enterprise V5.0, ION Enterprise V4.5, ION Enterprise V4.0

Is ION Enterprise 5.6 compatible with Microsoft Office XP or 2000?

Microsoft (MS) Office XP or 2000 are older versions of the MS Office suite. The Commissioning Guide for ION Enterprise recommends Excel 2003 as a minimum version and the earlier versions have not been tested by the Software department, however, there are customers who have successfully installed MS Office 2000 and ION Enterprise 5.6 together. If there are any problems using an older version of Office, the resolution is to upgrade to Office 2003.

Last Revised: November 22, 2007
Applies To: ION Enterprise 5.6
Public
All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL189470 V1.0, Originally authored by KBAdPM on 11/23/2007, Last Edited by KBAdPM on 11/23/2007
Related ranges: ION Enterprise V5.6

How can I find a lost code on Sepam 2000?

To find the lost code on a Sepam 2000 prior to 96/49:

go to the control logic in which the code (password) is given
 
To find the lost code of a Sepam 2000 later than or equal to 96/49, there are 2 options:

If the code has not been modified using the Pocket PC:
  • go to the control logic in which the code (password) is given.
If the code has been modified using the Pocket PC: 
  • re-load the control logic using LOGIPAM making a note of the code (password) used.

Note: The standard code (password) for the control logics is 6543210.

AP7003 (Network Air 1000) mobile air conditioner manual, install and parts

Issue:
AP7003 (Network Air 1000) Install Manual 

Product line: 
AP7003 (Network Air 1000)

Environment: 
All Serial Numbers 

Cause: 
Operations Manual 

Resolution:  
See attached document

 

 

 

Configuring Native USB Power Options in Windows 2000, XP, or 2003

Issue:
How to configure native USB power option.

Product Line/s:
Back-UPS
Smart-UPS

Environment:
Microsoft Windows 2000, XP or 2003

Cause:
Installation / Set-up

Solution:

Please see attached PDF.

How fast can the CM4000T update the analog outputs?

Issue:
A customer would like to know how fast the analog output status for a CM4000T can be updated for use in a high speed application.

Product Line:
CM4000T

Environment:
CM4000 I/O

Resolution:
The analog output statuses are updated once every 100 ms.  If the desired application requires faster update rates the 4000T may not be appropriate.

Will the 2000pp fit the C2000 series?

No, unfortunately you will need to use a C2000PP paint protector.

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=C2000PP

What is the separator for a 15092

 The separator part code is 27001

Can you get a cooker switch such as the C2031/45 in slimline SC series?

No, cooker switches are only available in C2000, 2000 and Saturn series.

Error Restoring SQL2000 database backup on SQL Server 2012

Issue:
The database was backed up on a server running version 8.00.0760. That version is incompatible with this server, which is running version 11.00.3128.

Product  Line:
SQL Server 2000
SQL Server 2012

Environment:
SQL Server Database Restoration

Cause:
It is not possible to restore a SQL Server 2000 database on SQL Server 2012.

Resolution:
You will need to restore the database on an instance of SQL Server 2005, 2008 or 2008 R2 first, then back it up from there, then restore the new backup on SQL Server 2012.



Which type of switch mechanism is used for the wall switch on the SILC system?

A standard bell press mechanism is used (momentary action). The products are currently in our Electrical Accessories range and the references are: 30PBBP-WE (suits Standard ranges, 2000, C2000, etc) and 60PBBP (suits Saturn and Saturn ZEN).
Please follow link below to find out more information of this product:
https://www.clipsal.com/Trade/search-results?q=silc

What TCP Port do ION Meters use for DNP v3.0 via Ethernet?

Issue:
What TCP port is used for the DNP 3.0 protocol when connecting to a meter via Ethernet.

Product Line:
ION meters

Environment:
ION meters

Cause:
Information Request

Resolution:
TCP port 20000 is used for the DNP v3.0 protocol via the Ethernet port.

What is the alternate to P2032E450UD, Prestige P2000, 450W Universal rotary dimmer?

P2032E450UD, Prestige P2000, 450W Universal rotary dimmer can be assembled with the below components:
P2032VH - P2000 Series, Grid and Cover Assembly - No Mechanisms, Standard size - 2 Gang Grid Assembly
P30M - Switch Mechanism - P2000 Series, 250V 10A - 2 way / 5 terminal.
P2032E450UDM - Light Dimmer Mechanism, P2000 Series, 250V 450W - Universal.
For further information, please visit
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2032VH
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P30M
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2032E450UDM



 

Can 2000 series and C2000 series, IP66 range of switches be used outdoors?

Clipsal IP66 2000 Series and C2000 Classic series switches are hardwearing, UV stabilised, polycarbonate surface and suitable for a wide variety of outdoor areas, such as carports and pergolas.
For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000083.pdf

Is there a 2010L in black?

The 2010L does not come in black as a standard colour. However you may be able to get it made as a special.

Does OFS V3.50 supports Windows 8

Yes, OPC v3.5 Factory Server is supported in Windows 8, Server 2012, Windows 7, Server 2008 R2, Vista, XP, 2000, and Server 200. OFS must not be installed on virtual machines.

Why is my Conext CL showing an alarm code: 2633 & 2634 (PV1 OC Wrn & PV2 OC Wrm Service Alarm)

Issue: 
Customer is calling to confirm an alarm code: 2633 & 2634 (PV1 OC Wrn & PV2 OC Wrm Service Alarm)

Product Line: 
Conext CL 18000NA Conext CL 25000NA Conext CL 20000 Conext CL 25000E

Environment:  
On site troubleshooting

Resolution: 
Check the PV1 or PV2 generator in the units power meter 
If the unit’s power meter doesn’t match with the readings on a handheld meter, replace the unit

Cause:
Improper string sizing
Problem on one MPPT input due to a string problem
Unbalanced current between 2 inputs > 100%
PV1 or PV2 input over current detected, hence the power output from PV1 or PV2 is stopped (half a power capability)

Active Alarms are not reporting in System Manager Software (SMS) from Series 2000, 3000, 4000 Circuit Monitors or Series 600, 800 Power Meters. The meter's front display indicates that the alarms is active.

 

The most common cause for alarms not coming into System Manager Software (SMS) from a device is when the onboard alarm log records are set to 0 (zero). Go to Setup>Device/Routing>configuration then verify that the number of records for the "alarm log" is not zero, 0. Verify that the alarm log is enabled.

This applies to the Series 2000, 3000, 4000 Circuit Monitors and Series 600, 800 Power Meters.
System Manager Software (SMS) v 3.3.x.x and 4.x




Date Created: Unknown
Last Revised: March 19, 2008
Public
Original Author: PMOZONE/PH
All content © 1992-2008 Schneider Electric

Legacy KB System (APS) Data: RESL185061 V2.0, Originally authored by KBAdPM on 06/27/2007, Last Edited by PhHa on 03/20/2008
Related ranges: System Manager 3.3, System Manager 4.0, System Manager 3.2

Do you have a 2000MF round mounting block with a diameter of 800?

Yes the part number is 2000MF800.

What are the part#'s for the Panelmate Plus Modbus Plus Interface Board?

The part #'s for the Panelmate Plus Modbus Plus Interface Boards are:
1) MM-PMMP001C - Panelmate Plus 2000 / 3000 / 4000 Modbus Plus Interface, CE
2) MM-PMMP002C - Panelmate Plus 2000 / 3000 / 4000, Dual MB+ Interface, CE
3) MM-PMMP003C - Panelmate Plus 1000 / 1500 Modbus Plus Interface, CE

What material is 2000 series made of?

The 2000 series is made of Polycarbonate.

For further information please visit https://www.clipsal.com/Trade/search-results?q=2000%20series&section=1_SWITCHES%20AND%20SOCKET%20OUTLETS

What is part number for 4 gang C-Bus 2000 series switch?

The part number for 4 gang C-Bus 2000 series switch is 5034NL.

What is part number for metal surround to suit 2000 series?

The part number for metal surround to suit 2000 series is 2000M-GD.

What is part number for 4 gang 2000 series surround?

The part number for 4 gang 2000 series surround 2000/4.

Microsoft SQL 2000 Server is taking 100% of the CPU

Goals and Symptoms

The Microsoft SQL server service is using 100% of the CPU process and the computer is running slow. If the computer is rebooted everything will appear to run fine for a while and then the SQL process is back at 100%.

Causes and Fixes

This is caused by the Slammer Worm that affects computers with SQL 2000. This worm does not destroy data, it is just nuisance. It is designed to make SQL server eat up all of the CPU. To resolve this issue applying Microsoft's SQL Server Service Pack 3 or later.

Attachments

(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/48d8a2c6b39833e2c125734d001606b1/fl_block_5/0.1AD6?OpenElement&FieldElemFormat=gif)


  • Last Revised: August 4, 2007

    Public

    All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL187891 V1.0, Originally authored by PhHa on 09/05/2007, Last Edited by PhHa on 09/05/2007
Related ranges: OS & related Third Party PRODUCTS for Power Mangement Systems, System Manager 4.0, System Manager 3.3

What is the lumens output for the FLH200LED?

The lumens output for the FLH200LED are - 20000 Lumens

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=FLH200LED

Specification: Black Die Cast Aluminium Body, IP65, Tempered Glass.
200 Watt, >20,000 Lumens, Efficacy 105 Lumens/Watt, CRI >70
Lamp Colour Temp 6500 ° Kelvin, Lamp Life 50,000 hrs (L70)
Dimensions: Body & Bracket – Width 438mm, Height 505mm, Depth 150mm
User-added image

What is the part number for a cover for Clipsal 2000 Flush Surround range?

2000-** colour

What year was 2000 series released?

Product was released in 1987.

Can you get the Magelis XBTGT range with Conformal Coating?

Yes, the product offering for Conformal Coating on the XBTGT line will be available in 6 Steps:


Conformal Coating Service for XBTGT 5.7, Sell stage gate in 10th July 2009: XBTGT2110, XBTGT2120, XBTGT2130, XBTGT2220, XBTGT2330

Conformal Coating Service for XBTGT 12.1, Sell stage gate in 1st August 2009: XBTGT6330, XBTGT6340

Conformal Coating Service for XBTGT 10.4, Sell stage gate in 1st September 2009: XBTGT5230, XBTGT5330, XBTGT5340

Conformal Coating Service for XBTGT 3.8, Sell stage gate in 1st October 2009: XBTGT1105, XBTGT1135, XBTGT1335

Conformal Coating Service for XBTGT 15, Sell stage gate in 1st November 2009: XBTGT7340

Conformal Coating Service for XBTGT 7.5, Sell stage gate in 1st December 2009: XBTGT4230, XBTGT4330, XBTGT4340

Is there a 1000V rated MCCB?

No there is no current MCCB that is 1000V rated , 690V is highest rating.

What is the frequency of the internal buzzer used in the Magelis XBTGT 2000 to 7000 series HMI terminals?


The buzzer frequency is between 2000Hz and 2600 Hz. (2300Hz typical)


Legacy KB System (APS) Data: RESL192877 V1.0, Originally authored by MiMe on 10/01/2008, Last Edited by MiMe on 10/01/2008
Related ranges: Magelis XBT G

With what Windows environments is the SFT2841 software compatible?

The SFT2841 setting and operating software tool may used with the following operating software:
* Windows XP professional
* Windows 2000, pack 2 and higher
* Windows NT 4.0 and higher
* Windows 95 and 98

Note: Work is in progress to present a Window Vista compatible release for Q4 2008.

Last Revised: 30 June 2008

Applies To:

Original Author: (recommended to place initials only)

Public

All content © 1992-2008 Schneider Electric

Can you get a 2000/2 in chrome.

This part  only comes in standard 'bakelite' colours. Please visit the below link to our website for more information and colour options.
Today, the 2000 series is clipsal’s most popular product range and its surrounds are available in a wide choice from single gang standard size versions to multigang surrounds for situations where you want to house up to four gridplates in a single surround. 2000 series flush surrounds feature a design that neatly conceals all mounting holes, a durable high gloss finish for easy cleaning and a clever clip on/clip off design that enables surrounds to be easily removed when redecorating to conceal overpainting or untidy cut marks when wallpapering.
Please see following link for more details and colour choices of multi gang range.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000/2

Is part number FLR30LED available below 6000k?

No. Unfortunately, the part is not available below 6000k.

What is the load rating of the INS62043?

200KG listed in the floor box catalog.

UPS fails Insulation Resistance Test (PAT Test)

Normally the Insulation Resistance value should be around 1 M ohm. However this problem is usually caused by the way this test is carried out. The usual method for carrying out by such a test is shorting out phase and neutral and measuring them against earth. However when doing so you are connecting all the internal resistors in parallel which causes a low reading of resistance. If the test is done using a high voltage, 500V DC, the unit will also allow excess Voltage to flow to Earth (Ground) to protect the load but this will show as a drop in resistance for measurement applications. Most European Regulations e.g. IEE 16. edition, section 10.3.3, require all electronic components to be disconnected before carrying out such tests. The surge protection in our UPS’s is achieved by using MOV’s which have a certain let through Voltage.

 

Please note that using 500V DC to carry out this test, may damage the UPS and such damage will not be covered by APC warranty. In our factory we carry out such a test using 2000V but with the critical electronics disconnected from earth. This is further explained in the attached document.

What is the part number for the floor pedestal outlet box that can have back to back 2000 & C2000 Series switch plates and GPO's?

The part number for the floor pedestal outlet box that can have back to back 2000 & C2000 Series switch plates and GPO's is - FP125DBL

For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=FP125DBL

What are the Minimum System Requirements to run XBTL1000 V4.5?

The Minimum System Requirements for XBTL1000 V4.5 are:
PC Pentium II 350 MHz
Minimum 4x CD-ROM drive
Windows 98, 2000, or XP
64 MB RAM (128 MB RAM recommended for WIN 2000/XP
30 MB Hard Drive space
SVGA video or higher
Mouse or compatible pointer system


What is the 2000 series blank plate

 The part code 2031VX-WE
Show More