COVER PVC 1 GANG DEEP SURROUND
cover pvc 1gang deep surr
COVER PVC 1 GANG DEEP SURROUND
cover pvc 1gang deep surr

Mounting Blocks and Flanges, Deep SurRound to Suit 2000 Series

Catalogue Number: 2000SM
COVER PVC 1 GANG DEEP SURROUND
cover pvc 1gang deep surr
COVER PVC 1 GANG DEEP SURROUND
cover pvc 1gang deep surr
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Mounting position
horizontal
Material
PVC (polyvinyl chloride)
Depth
27 mm
Length
118 mm
Width
76 mm
Sustainable offer status
Green Premium product
REACh Regulation
Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Product Environmental

  • Installation Instruction

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the part number for standard din rail?

The part number for standard din rail is NSYSDR200B. It is 7.5mm deep by 2000mm long.

Can you get a plate larger than 6 gang in the 2000 series?

Not directly, but using the 2000/2 or 2000h2 series you can fit 2 plates under one surround.

Do you have a 2000MF round mounting block with a diameter of 800?

Yes the part number is 2000MF800.

Does PowerLogic SCADA support waveform data of ION meters?

No, Powerlogic SCADA (PLS) currently does not support the waveform data from ION meters; valid through PLS v7.10 SR3.
Waveforms from the following devices are currently supported as of v7.10 SR3: Circuit Monitor 3000s, Circuit Monitor 4000s, Power Meter 800s, and Sepam 20s, 40s, and 80s.


Legacy KB System (APS) Data: RESL200266 V2.0, Originally authored by KBAdPM on 10/16/2009, Last Edited by MaTh on 12/01/2010
Related ranges: PowerLogic SCADA 7.1

Are there any plaster clips or other accessories for 2000/3 ?

We only make wall boxes for this 2000/3
The Part number is 2157/3  or 2157/3SB1 or 2157/3SB2

Will the 2000pp fit the C2000 series?

No, unfortunately you will need to use a C2000PP paint protector.

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=C2000PP

Is there any bracket available for a 2000/4?

There is no stud bracket, you could use the 2154/4 mounting clip.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2154/4

Do you have a 45RU data cabinet 800mm Wide X 1000mm Deep?

Yes, the part number is 3106N45C810-BK.

What is the part number for a 45RU data cabinet , 800mm wide and 1000mm deep?

The part number for a 45Ru data cabinet that has dimensions of W800m x D1000mm is - 3106N45C810

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3106N45C810

Is Silver color on part 2000/2 same as Brushed Aluminium?

The Silver color is shinier than Brushed Aluminium and is distinctly different

for information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000/2

User-added image

What is the part number for Moduline ducting 35x150?

Part number is PL35150D available in White,Black,Natural Anodised & Oyster Grey and it is 2400mm long.

What is length of part no PL35125D

Part no PL35125D is 2400mm long

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=PL35125DW

What is the plaster bracket to suit the 2000/2?

The part number for the plaster bracket to suit the 2000/2 is 2155PRM/2.

My meter is measuring 0A and 0kW but correctly reads the Voltage, what is the issue?

Product Line
ION Meters

Environment
Installation/Setup

Resolution
If the meter is being provided a very small current (0.005A/5mA or less) on the secondary side, the meter will read 0 for the phase current.
Since kW is dependent on the current reading this value will also be zero.

To find out what the minimum Primary starting current is you can calculate as follows:
Primary_Min_Current = 0.005 * CT_Ratio
Where CT_Ratio = CT_Primary/CT_Secondary

Example:
CT Ratio = 2000:5 (Primary:Secondary)
Starting Current = 0.005A (Secondary)

CT_Ratio = 2000/5 = 400
Primary_Min_Current > 0.005 * 400 = 2A (primary side load).

 

How can you decode a Masterpact catalog number to determine construction?

Issue:
How can you decode a Masterpact NW or Masterpact NT catalog number to determine construction features such as ratings, accessories, trip unit, connectors, etc.?

Product Line:
Circuit Breakers

Environment:
Masterpact NW

Cause:
Catalog numbers are intelligent but coded

Resolution:
To decode a catalog number, access the attached file and find the description corresponding to each character for the breaker catalog number and for the cradle if applicable.
PLS007 is for Masterpact Circuit Breakers.
PLS012 is for Masterpact Cradles.

Note: For Masterpact breakers (eg. WA8AHR31A2SNNNNNNN9N) from late 1990s to very early 2000s, check attached 1999 decoder.

What is the maximum altitude an ATV61 or ATV71 series drive can be used at?

Issue:
What is the maximum altitude an ATV61 or ATV71 series drive can be used at?

Product Line:
Altivar 61, Altivar 71 series drives.

Environment:
All models, All serial numbers.

Cause:
Elevation vs current rating

Resolution:
The Altivar  61 and 71 series drives can be used at full rating up to 1000 meters above sea level. They must then be derated by 1% for every additional 100 meters up to a maximum of 3000 meters above sea level.
Note that the ATV61H***S6X and ATV71H***S6X drives must not be used with corner grounded systems at altitudes above 2000m.

Is it Possible to Upgrade a 1600A NW16 Breaker to a 2000A NW20 by Changing the Sensor Plug.

No. It is not possible. As per the attached document the NW16 have sensor rating only from 800 - 1600A, So a 2000A Sensor Plug is not suitable for NW16 Breaker. So it can not be changed. 

What is the frequency of the internal buzzer used in the Magelis XBTGT 2000 to 7000 series HMI terminals?


The buzzer frequency is between 2000Hz and 2600 Hz. (2300Hz typical)


Legacy KB System (APS) Data: RESL192877 V1.0, Originally authored by MiMe on 10/01/2008, Last Edited by MiMe on 10/01/2008
Related ranges: Magelis XBT G

Can I change the input power plug on my 120Vac Smart-UPS?

Issue:
Changing input plugs on Smart-UPS 2000VA or larger

Product Line:
Smart-UPS 

Environment:
Smart-UPS 2000VA or larger

Cause:
All Smart-UPS 2000VA or larger have an input plug that is not a standard 5-15 household style plug.

Resolution:
The higher capacity of these UPS models require an input plug that is either 20amp or 30 amp (depending on model) rather than the traditional 15 amp household plug you may be more familiar with. The UL listing of the UPS assumes that the UPS is using the input plug for which it was designed. Modifying the input plug may affect the UL or other regulatory compliance. Schneider Electric does not recommend modifying the input plug of your Smart-UPS UPS or attached Smart-UPS Accesories (IE: Stepdown Transformers, PDU strips, ETC) 

Note: If you decide to go against this recommendation and change the input plug of your UPS, please be aware that the functional capacity of the UPS will be limited by the input circuit.
(I E: An SMT3000 being supplied 15 amps is effectively a 1500VA UPS rather than the 3000VA that it is rated for.)

The ACSC100 manual lists an In-Rush current of 56amps for 200ms. How does this not trip the 20amp breaker?

Issue:
The ACSC100 manual lists an In-Rush current of 56amps for 200ms.  How does this not trip the 20amp breaker?
Product line:
ACSC100
Environment:
InRow Cooling
Cause:
 
Resolution:
The reason that the circuit breaker does not trip is expressed in the time/current curve that are unique properties of circuit breakers or fuses. For example a typical Square ""D"" ""NQ"" breaker rated at 20 amps might trip after 300 seconds of a 20 amp load, but will pass considerably more than 56 amps at 200ms of time.

What are the dimension for the 2000H2?

The dimension for the 2000H2 are - H232mm x W 76mm x D13mm

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=2000H2
User-added image

Does the TALplus PL50150DB trunking come with a lid?

No, unfortunately the ducting lid is sold separately. the part number is PL150CFC*.
The Lid is 1200mm long a pose to the trunking which is 2400mm therefore you will need 2 lengths of lid per lengths of ducting.

What is part number for 200mm pull cord wall fan?

The part number for 200mm pull cord wall fan is 7108A.

What is part number for 200mm window fan?

No unfortunately there is no 200mm window fan available.

What is the effect of altitude on ATV312?

Product Line:
All ATV312 and ATV31

Environment:
High altitude, more than 1000m

Cause:
What is the effect of the high altitude on the drive.

Resolution:
For all ATV312, less than 1000m, no derating.
For single-phase supplie and corner grounded distribution networks, up to 2000m, derateing 1% per 100m.
For three-phase supplies, up to 3000m, derating 1% per 100m.




 

What is the part number for the internal barrier for the PL50150D skirting duct?

The part number for the internal barrier for the PL50150D skirting duct is PL50IB.

Some of the key features are:
  • 2.4m Length
  • Duct size: 2400mm Length x 150mm Height x 50mm Depth
For further information please visithttps://www.clipsal.com/Trade/Products/ProductDetail?catno=PL50IB

Is there a wall box for a 2025H2?

The wall box for the 2025H2 is the 2157H2.

Some of the key features are:
  • 2 gang
  • 84 mm (2 sets)
  • With sliding nuts for accurate alignment of accessory
  • Precision stamped from 0.9 mm strip bright electrogalvanised, for 2000H2 series

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2157H2

 

Is the 600SM available in red

No, it only comes with White and Black covers.

Can you get a 2000/2 in chrome.

This part  only comes in standard 'bakelite' colours. Please visit the below link to our website for more information and colour options.
Today, the 2000 series is clipsal’s most popular product range and its surrounds are available in a wide choice from single gang standard size versions to multigang surrounds for situations where you want to house up to four gridplates in a single surround. 2000 series flush surrounds feature a design that neatly conceals all mounting holes, a durable high gloss finish for easy cleaning and a clever clip on/clip off design that enables surrounds to be easily removed when redecorating to conceal overpainting or untidy cut marks when wallpapering.
Please see following link for more details and colour choices of multi gang range.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000/2

What is the part number of Mounting bracket for a 2000/2?

The part number for a for a mounting bracket for a 2000/2 is 2154/2.

Some of the key features are:
  • Mounting brackets
  • 2 gang
  • For plaster board or hardboard mounting for wall boards up to 12 mm thick

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2154/2
 

Why is my Conext CL showing an alarm code: 31 (AC Curr Snsr Flt Service Alarm)

Issue: 
Customer is calling to confirm alarm code: 31 (AC Curr Snsr Flt Service Alarm)

Product Line: 
Conext CL 18000NA Conext CL 25000NA Conext CL 20000E Conext CL 25000E

Environment:  
On site troubleshooting

Cause:
AC current sensor doesn’t measure the grid current accurately
Grid connection
Detection circuit malfunction

Resolution: 
Check AC connection on inverter

Is it possible to mount a weathershield power point on a pole ?

Weather shield enclosure will line up with the 2000MF range, screw mountings will go on an angle to the pole, opposing the enclosure and may be tricky.
Available standard as white. If diameter surface is less than 300mm you may be able to use a 56PMK.
2000MFV range has a large amount of variable for different sized diameter surfaces.
Please see following link for complete range of sizes
https://www.clipsal.com/Trade/search-results?q=2000mf
 

PDL600SM - 600SM can it protect downstream or will it only protect the socket in that plate?

The 600SM protects all other devices on the circuit but it can only handle a limited number of surges.
For more information see attched installation sheet.

What is the part number for an LED flood light that has 20000 Lumens output?

The part number for an LED flood light that has 20000 Lumens output is - FLH200LED

For further information , visit link below:-
User-added image
https://www.clipsal.com/Trade/search-results?q=FLH200LED
 

Sepam EcoFit offer

Schneider Electric offers a retrofit solution for converting Sepam 2000's to the new Sepam 1000+ relays.
ECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT SEPAM 2000 Customer Presentation Rev1a.pptECOFIT SEPAM 2000 Customer Presentation Rev1a.ppt

VijeoLook V2.6 : during the installation, error "1603" and then another error "Missing MSDN 2000". How to solve it ?

Goals and Symptoms

VijeoLook V2.6 : during the installation, error "1603" and then another error "Missing MSDN 2000". How to solve it ?

Causes and Fixes

During the installation of VijeoLook, if you have a problem with MSDN 2000 (error 1603), then you have to check the Status and the Startup type of those 2 Services "Server" and "Computer Browser" (Control Panel \Administrative Tools \ Services).
They must be started in automatic :
---------------------------------------------------------------------------------------
// Name // Status // Startup Type //
---------------------------------------------------------------------------------------
// Computer Browser // Started // Automatic //
// Server // Started // Automatic //


Legacy KB System (APS) Data: RESL177610 V1.0, Originally authored by on , Last Edited by on
Related ranges: Vijeo Look

Is there a sleep mode in either ADVC2 or PTCC controller?

Issue
Is there a sleep mode in either ADVC2 or PTCC controllers that will make it go into sleep mode if power has not been restored for a certain period of time

Product Line
ADVC2 controllers
PTCC controllers

Environment
Backup battery

Resolution
There is not sleep mode but there are "Low Power Mode" and Shutdown mode.
- When DC volt is less than 18V within 8ms (Eg Trip/close in battery condition) controller goes into Low Power Mode where Radio supply is shut down, capacitor charge is at lower rate.
- If DC voltage is less than 20V for more than 200ms, controller goes into shutdown mode

 

What is the diameter of a 94CL ceiling light

The diameter is 200mm x 95mm

What are the dimensions for SIGN/BPA & SIGN/CPA?

90mm (H) x 200mm (W)

Is there a 200mm exhaust fan available?

Yes, the part number is 7106A

How do I get Modsoft to open up to full screen display while I try to run it under WIN 2000?

The command to get Modsoft to change window size is ALT+<ENTER>; however Modsoft is not supported under WIN 2000. Users may try running the application under it; however successful operation cannot be guaranteed. One of the common problems is Modsoft will not open up to full screen. Regrettably there is no means to resolve this issue other than to reinstall the software under a supported OS, such as WIN 95, WIN 98 or DOS.


Legacy KB System (APS) Data: RESL171500 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modsoft

What is the altitude derating for a TeSys D-Line contactor?

Issue:​
What is the altitude derating for a TeSys D-Line contactor?

Product Line:
Digest 177 Section 18 : Contactors and Starters, IEC

Environment:
North American Products

Resolution:
The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

Voltage
3500m x 0.90
4000m x 0.80
4500m x 0.70
5000m x 0.60

Current
3500m x 0.92
4000m x 0.90
4500m x 0.88
5000m x 0.86

For example, an LC1D80 at 5000 meters:
- The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
- The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



 

What is the part number for a 200mm wall ex-fan with auto shutters?

The part number for a 200mm wall ex-fan with auto shutters is - 7106A
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=7106A
User-added image

What is part number for 200mm Tal plus duct?

The part number for 200mm Tal plus duct is a PL500200D.

for more information on this part please refer to https://www.clipsal.com/Trade/search-results?q=PL50200D

What is the part number for skirting duct 50mm deep and 200mm high ?

the part number for skirting duct 50mm deep and 200mm high is - PL50200D

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=PL50200D
 

What surge protection can I use behind a powerpoint in the 600 series

 Use a PDL 600SM with a 600 series socket with an extra switch

PDL600SM SURGE PROTECTION MODULE Do we have in Black?

When you purchase a 600SM it comes with a White and Black cover and you can put on either one.

Why is my Conext CL showing an alarm code:2418 & 2419 (AC UV Slow Err & AC OV Slow Err Service Alarm)

Issue: 
Customer is calling to confirm alarm code:2418 & 2419 (AC UV slow err & AC OV slow err Service)

Product Line: 
Conext CL 18000NA Conext CL 25000NA Conext CL 20000E Conext CL 25000E

Environment:  
On site troubleshooting

Cause:
AC voltage is below (Under Voltage) or above (Over Voltage) the set limits
AC Voltages are not according to the set country or custom setting

Resolution: 
Measure the voltage at the inverter AC connections and check if it is within the country or custom setting limits, adjust if necessary in accordance with utility.

Why is my Conext CL showing an alarm code:8000 (AC Internal Error Service Alarm)

Issue: 
Customer is calling to confirm alarm code:8000 (AC Internal Error Service Alarm)

Product Line: 
Conext CL 18000NA Conext CL 25000NA Conext CL 20000E Conext CL 25000E

Environment:  
On site troubleshooting

Cause:
Grid current measured exceeds unit rating
DC bus voltage outside operational parameters
Internal AC bus voltage too high
Phase lock loop failure during inverting

Resolution: 
Reset unit by turn off both AC and DC
If problem persist replace the unit
 
 

Why is my Conext CL showing an alarm code: 9000 (DC Internal Error Service Alarm)

Issue: 
Customer is calling to confirm alarm code: 9000 (DC Internal Error Service Alarm)

Product Line: 
Conext CL 18000NA Conext CL 25000NA Conext CL 20000E Conext CL 25000E

Environment:  
On site troubleshooting

Cause:
PV current measured exceeds unit rating
Internal DC bus voltage too high
Difference between top or bottom DC bus voltage too high
Dc bus voltage too low
DC voltage sensor measurement failure

Resolution: 
Reset unit by turn off both AC and DC
If problem, persist replace the unit
Show More