194

General Accessories Panel Mount Outlet Square, 10A, 1.0MM RP Socket

Catalogue Number: 194
194
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
PDL
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
Mounting support
panel
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Standards
  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133
  • AS/NZS 3000:approval number S/1
    • Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Technical Leaflet

      • Installation Instruction

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the round earth pin version of a PDL 194?

      There is no round earth version of the 194 available.

      What is the cut out size for (PDL) 194 panel mount socket with tab terminals

      Cut out size 38mm x 32mm

      What are the dimensions of the PDL194 socket?

      Height = 41.8 mm
      Width = 48.2 mm
      Cutout of 38x32 ​
       

      Can the 681 switch fluorescent lights

      Yes but only up to 19A

      Is the 193 in a 20amp available?

      Yes, the part name is 193/20-1.

      Which UPS is the Correct UPS for My Configuration?

      APC by Schneider Electric has an online sizing tool that will help you find a UPS that will fit your needs. The APC UPS Selector is located at https://www.apc.com/tools/ups_selector/.

      Alternatively, please visit the APC UPS Buying Guide for selecting the right battery backup.

      Are electrical cabinet keys Number 144 available?

      Yes the key number 144 is available as a GAEL product, code is DK1. C/W cam lock and 2 keys.

      What is the 154 that suits the Slimline range?

      The 154 to suit the Slimline range is the 154RM.

      What would be the solution to connect a Magelis application using IEEE 1394 interface

      Today we have no such connection for the IEEE 1394 interface on the Magelis series of HMIs

      XBT, HMIGTO, HMIGTU, HMISTO, HMISTU series.

      Do we have a 20Amp PDL 694 Switched Socket Outlet ?

      No - Rated at 15A =  PDL694/15WH

      What does the 19” measurement refer to?

      The 19” measurement refers to the width of the Rack Unit.

      Is there a 154 C-clip that does thicker than 10mm plasterboard/ gyprock?

      Yes the 154/1 does plasterboard/gyprock thickness's between 19-25mm.

      what are the dimensions of the ATV312HU40N4?

      Height 184 mm
      Width 142 mm
      Depth 152 mm

      Where can I find the ASB230501 Data Sheet?

      Attached is the ASB230501 Data Sheet.

      Can I fit 4 sockets on a PDL 144 flush box

      Use a PDL 149 and 2 doubles

      What is the part code for a 15A version of 570S

      There is no 15A version of 570S, only in the 193 range which are round not square ie 193/15/1

      486d is having issues - have replaced battery but still reads low on screen

      It would be recommended to get it serviced / calibrated by Trio Smartcal 1300 134 091

      What is the part number for a 154 in a 4 gang application?

      The part number for a 154 in a 4 gang application is a 2154/4.
      Some of the key features are:
      • Mounting brackets
      • 4 gang
      • For plasterboard or hardboard mounting
      • Including 2025V3/30PF
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=2154/4

       

      Why do I get a warning about using a power supply with a 140CRA211xx DIO Adapter?

      Title
      140CRA211xx DIO Adapter power supply warning
       
      Issue
      140CRA211xx DIO Adapter power supply warning
       
      Product Line
      Quantum.
       
      Environment
      Unity
       
      Cause
      N/A
       
      Resolution
       The purpose of the Warning, is because the 140CRA211xx DIO Adapter has its own built in power supply.
      You are cautioned to "DO NOT WIRE THE DIO ADAPTER POWER CONNECTOR WHEN BEING USED THIS WAY"
      The two power supplies it can be used with are the 140 CPS 114 00 & 140 CPS 124 00. When the 140CRA211xx DIO Adapter is used with an 8 amp power supply is  will consume approximately 0.5 amps. 
       

      Where in the 2014 PDL Pocketbook can I find the BALS Product?

      PDL page 76 and 154

      Netbotz Upgrade Problem With Windows XP Firewall

      Issue:

      Netbotz Upgrade Problem With Windows XP Firewall

      Product Line:

      NetBotz

      Environment:

      NetBotz Upgrade (all versions)

      Cause:

      Windows Firewall.

      Resolution:

      The built in Firewall that comes standard with Microsoft Windows XP may interfere with upgrading NetBotz products from the NetBotz Central Console or the Advanced View. If a null pointer exception occurs during an upgrade, exit the application and turn off the firewall temporarily.

      The following explains how to turn off the Windows XP firewall.

      Windows XP firewall (Without SP2)

      1. Click Start, 2. Control Panel, 3. Double click Network Connections, 4. Right-click the desired connection, 5. Properties, 6. Advanced tab, 7. Under Internet Connection Firewall, 8. Uncheck or check the "Protect my computer and network by limiting or preventing access to this computer from the Internet" check box.

      Windows XP firewall (With SP2) Note: In Microsoft Windows XP Service Pack 2 (SP2), Windows Firewall is turned on by default. To turn off is much simpler to disable.

      1. Click Start 2. Control Panel 3. Windows Firewall 4. Select "Off (not recommended)" 

      IMPORTANT:Remember to turn the Windows firewall back on after you complete your NetBotz upgrade."

      Please note newer versions of Windows OS and other firewalls may have similar issues.
       

      Are spare keys available for DK1

       Not available as a spare part.  You will need to buy a new lock (which comes with 2 spare 144 keys)

      What is the part number for a 3P 200amp front wired main switch

      T200FA-BK this comes with cover
       
      PDL Book page 124 (2014)

      ION7650 or ION7550 meter gives Error 195 on the front panel.

      If Error 195 appears on the front panel of an ION7650 or ION7550 meter upgrading to the latest firmware (v352) will resolve this issue.

      Date Created: October 30, 2008
      Last Revised: May 1, 2009
      Public
      Original Author: MN
      All content © 1992-2009 Schneider Electric

      What are the maximum IO counts for the M251 using the TM3 Expansion modules?

      For discrete IO modules, you can have up to 488 digital IO counts.
      For Analog IO modules, you can have up to 114 analog IO counts.

      What wall clips are suited to the BSL range?

      You can use the 154 provided you allow a 10mm gap.

      What Ethernet frame types are supported by the TSXETG1010 module?

      The Ethernet frame types that are supported by the TSXETG1010 module are:
      Ethernet II format, corresponding to standard RFC 894 (the most commonly used) and
      802.3 format, corresponding to standard RFC 1042.


      Legacy KB System (APS) Data: RESL174655 V2.0, Originally authored by MiOB on 07/30/2013, Last Edited by GeMc on 07/30/2013
      Related ranges: Modicon Atrium

      Is there a slim weatherproof enclosure cover?

      Yes, the part number is 223H
      Some of the key features are:
      • 84 mm Mounting centre apart (94 x 50 mm)
      • Horizontal
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=223H


      How many Clipsal 90 degree sweep bends (247/32-GY )come in a box ?

      Ten in a box  (clipsal page 104  - 2014 Pocket Book)

      What is the maximum motor cable length for an ATV312?

      Issue:
      What is the maximum cable distance from an ATV312 drive to the motor?

      Product line:
      ATV312, Altivar 312, ATV320, Altivar 320

      Environment:
      All models

      Cause:
      n/a

      Resolution:
      The ATV312 shows that an output filter or choke is required for any cable distance between the drive and motor exceeding 164 feet (50 meters).  Above 164 feet, there is a change with shielded vs non-shielded.

      Shielded cables
      From 164 feet to 330 feet (100 meters) you can use the LR filter cell or a motor choke.

      Unshielded cables
      From 164 feet to 660 feet (200 meters) you can use the LR filter cell or a motor choke.
       

      HomeSafe - Dimensions of Reed switches

      The below list are all measured in mm - all Reed Switches are Normally Closed with the magnet in place (NC)

      5460               18h x 19w x 13d
      5460FD            19(dia)
      5460FS            9.5(dia)
      5460HD            88h x 38w x 10d (cable lenght: 280)
      5460RF            78h x 73w x 27d

      What are the different types of electrical and hydraulic (fluid) connection for XMLA and XMLB pressure switches?

      For XMLA and XMLB pressure switches, the last 3 digits of the product code (S11, S12, S13 or S14) determine the thread of the electrical and hydraulic connections

      The various types of electrical connection are as follows:

      • S11: PG13.5 (DIN 46255 or NFC 68311)
      • S12: M20 (BS4568)
      • S13: 1/2 -14 NPT (ANSI B2-1)
      • S14: 1/2 PF (JIS B0202)

      The various types of hydraulic connection are as follows:

      • S11: 1/4 BSP (ISO 228)
      • S12: 1/4 BSP (BS 2779 or ISO 228)
      • S13: 1/4 -18 NPTF (ANSI B1.20.3)
      • S14: 1/4 PT (JIS B0203)

      Note :

      • There is no male hydraulic connection.
      • There is also no 1/2" female thread for hydraulic connection.

      Caution: Not all variants are possible. You should check the part numbers.

      How many SCADA clients can be connected to an Easergy T300 using IEC 104 protocol?

      • There is a limitation of 8 redundant connections to create multiple SCADA channels using the IEC104 protocol. Create 1 channel per client.
      • Make sure to fill-in the Remote IP@ list field. It shall be different for every channel
      • Please refer to attached file   

      Should address 199 be assigned to a CM2000 meter?

      Issue
      A CM2000 can be assigned an address from 1-199; however, should address 199 be used?

      Product Line
      CM2000 Series

      Environment
      Meter Addressing

      Resolution
      Address "199" should always be reserved. The circuit monitor will accept 199, but this is the address that the Circuit Monitor defaults to in a failure situation. 

      For steps on setting the CM2000's device address, please refer to FA218954.

      Trend graph object is not drawing anything in Vijeo XD Runtime

      When this occurs, it is likely that your trend graph object is corrupt. To resolve this, delete the trend graph object and draw a new one.

      Fiber Pod Extender Signal Quality Variance

      Issue:

      Fiber Pod Extender Signal Quality Variance

      Product Line:

      NetBotz

      Environment:

      NetBotz Fiber pod extender NBAC0212

      Cause:

      NetBotz can still communicate with pods even with some signal loss.

      Resolution:

      The NetBotz Fiber Pod Extenders will function properly with up to 10dB level of signal loss between the local and remote units of the extender.

      Example of Command from SCADA/IEC104 to a SC110/MODBUS to operate a switch

      Please refer to attached file 

      What are the dimensions of the SBIP2P pop up power socket?

      The front plate is 119 high x 124 wide.
      The enclosure is 62mm deep. The minimum depth is 80mm deep from the surface when mounted in 18mm (minimum) panel thickness. The maximum panel thickness is 38mm.
      Cutout is 105mm x 105mm


       

      What are the dimensions of LC1D40AB7 ?

      Height 122 mm
      Width 55 mm
      Depth 120 mm
      Product weight 1.4 kg

      What parts make up the XB4BA31 Green Pushbutton assembly?

      XB4BA31 = ZB4BA3 + ZB4BZ101
       

      Converting Symmetra LX to and from rackmount and tower configuration

      Issue
      I want to convert a Symmetra LX in tower form factor to rackmount form factor or vice versa.  How can I do this?

      Product Line
      Symmetra LX

      Environment
      All serial ranges

      Cause
      APC by Schneider Electric offers customers the choice of a a rackmountable UPS or a tower UPS at purchase time.  However, if the needs of the business change, a customer is able to modify the Symmetra.

      Resolution
      Use the following guidelines when converting from rackmount to tower form factor.  


      CONVERTING FROM TOWER TO RACK-MOUNT:

      Part(s) needed: SYAOPT1 - Symmetra LX rack mount 4 post rail kit

      In order to convert a Symmetra LX tower to a rack mountable UPS, you must remove the side panels, top panel, side panel support brackets, pallet support brackets, and casters. APCs recommendation is that an APC certified field service technician assists with this, as the frame must be carefully tipped to remove the casters. Please contact APC Customer Support for further information regarding a technician visit.

      After removing those pieces, follow the instructions on installing the rail kit and mounting the frame inside the rack. The modules inside the UPS should be removed during this process. Once the frame is secured in place in the rack, reinstall the modules and follow the instructions for powering on the UPS and load.


      CONVERTING FROM RACK-MOUNT TO TOWER:

      Parts needed (quantities specified): 
      (1) SYAFSU8 - Symmetra LX top panel
      (2) SYAFSU6 - Symmetra LX castors (left front, right rear)
      (2) SYAFSU7 - Symmetra LX castors (right front, left rear)
      (1) SYAFSU10R - Symmetra LX 19U right side panel*
      (1) SYAFSU10L - Symmetra LX 19U left side panel*
      (3) 870-3858B - Roof Stiffener Bars 
      (8) 810-0009A - Screws 
      (6) 810-2003 - Hex Nuts 

      * the 19U side panels are for the SYA16K16RMP models, if converting a SYA8K8RMP, the 13U side panels should be used - SYAFSU9L, SYAFSU9R

      APCs recommendation is that an APC certified field service technician assists with this, as the frame must be carefully tipped to install the casters. Contact APC for further information on a technician visit.

      If seismic floor anchoring is required with tower configuration, please refer to FA236776: Symmetra LX Seismic Anchoring for Tower Models

      Is there an example on how to Sync the time between an HMISTU and M241?

      Please see attached application

      What are the minimum and maximum cable specifications for Remote I/O ( RIO )?

      Maximum drop length is 164 feet.
      Minimum drop length is 8.5 feet.
      Maximum trunk length is 8400 feet using RG11 and 4600 feet using RG6.
      Maximum overall attenuation for the network is 35 db.
      Minimum distance between taps is 8.5 feet.
      Minimum distance between the RIO head and the self terminating "F" adapter is 18 inches.
      Minimum distance between the self terminating "F" adapter and splitter 8.5 feet.


      What are the specifications for the STO inputs on the ATV Process drives?

      Issue:   
      What are the specifications for the STO inputs on the ATV Process drives?
       
      Product Line:   
      Altivar Process Drives
       
      Environment:  
      All
       
      Cause:  
      STO inputs specifications
       
      Resolution:   
      Characteristics of ATV Process STO inputs
       PLC compatibility:  complies with IEC/EN61131-2 logic type 1 and type 3, for voltage levels
       Positive logic (Source):
        State 0 if  ≤ 5Vdc or STO not wired,
        State 1 if ≥ 11Vdc
       Impedance:     ≥ 2.2kΩ
       Maximum current:      10mA min at 19V input for external (Preventa) Relay
       Response time:      10ms

      ION9000 Part Numbers and Accessories

      Issue
      ION9000 Part Numbers and Accessories

      Product Line
      ION9000 series meter

      Environment
      Part Numbers

      Cause
      Where to find part numbers for the ION9000 series meter and its accessories

      Resolution
      ION9000 Basic Models and Display Accessories:
      References Description
      METSEION92030 ION9000 meter, DIN mount, no display, HW kit
      Meter Hardware Kit: plugs, terminal guards, spare grounding screw, DIN clips, terminal sealing covers and
      Current input Hardware Kit: terminal covers, CT input screws, terminal sealing cover
      METSEION92040 ION9000 meter, DIN mount, 192 mm display, B2B adapter, HW kit
      All the above + Display Hardware Kit: mounting nut, DIN 96 adapter, 3 meter cable, centering pin, mounting template
      METSEPM89RD96 Remote display, color LCD, 96 x 96 mm
      METSERD192 Remote display, color touchscreen, 192 x 192 mm

      ION9000 Accessories - I/O Modules, Adapters, Demo Kit:
      References Description
      METSEPM89M2600 I/O module, 2 relay outputs, 6 digital inputs
      METSEPM89M0024 I/O module, 2 analog outputs, 4 analog inputs
      METSE9B2BMA ION9000 B2B adapter
      METSEION902040DEMOK ION9000 Demo Kit
      METSE7X4MAK ION7x50 Mounting Adapter kit

      ION9000 Accessories - Hardware Kits:
      References Description
      METSE9HWK ION9000 meter hardware kit
      • plugs, terminal guards, spare grounding screw, DIN clips, terminal sealing covers
      METSERD192HWK RD192 remote display hardware kit
      • mounting nut, DIN 96 adapter, 3 meter cable, centering pin, mounting template
      METSE9USBK ION9000 USB cover hardware kit
      • replacement door for the USB ports
      METSE9CTHWK ION9000 current input hardware kit
      • terminal covers, CT input screws, terminal sealing cover
      METSEPMBATK Battery replacement kit for ION7400, ION9000, PM8000
      • Battery for real-time clock; typically only needed if required by customer policy

      What is the maximum motor lead length you can run the ATV320 drive without a load reactor?

      Issue:
      What is the max cable length you can run the ATV320 drive without a load reactor?

      Product Line:
      Altivar 320

      Environment:
      All

      Cause:
      Motor cable length distance without a load reactor. 

      Resolution:
      The ATV320 drive can run up to 164 feet without load reactor.  
      You can go up to 328 feet with shielded cable or up to 656 feet with an unshielded cable.
      See the table in the attachment.

      What is the part number for PDL single p/point with extra switch?

      The part number for PDL single p/point with extra switch is 694X-WH.
      Some of the Key Features are:
      • Larger rockers, matching the rockers on switch modules
      • Suits Cat 144 Flush Box and Cat 148H or 146H Mounting Bracket, Suits Cat 694M Metal cover plate
      • Removable extra switch 20 A

      For more information , please visit: https://www.clipsal.com/Trade/Products/ProductDetail?catno=694X

      What is the part number for a 56 series 3 phase changover switch?

       The part number for a 56 series 3 phase changeover switch is 56SW420CO.

      Some of the key features are:
      • 1 gang
      • 107 mm Height x 101 mm Width x 124 mm Depth
      • 3 Phase
      • 8 mm hole diameter
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56SW420CO

      What is the part number for a weatherproof 20A changeover switch?

      The part number for a weatherproof 20A changeover switch is 56SW220CO.

      Some of the key features are:
      • 1 gang
      • 107 mm Height x 101 mm Width x 124 mm Depth
      • 8 mm hole diameter
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56SW220CO

      SNMP MIB for NetBotz Version 2 Appliances

      Issue:

      SNMP MIB for NetBotz Version 2 and 3 Appliances

      Product Line:

      NetBotz

      Environment:

      NetBotz version 2 and 3

      Cause:

      Downloading SNMP MIB.

      Resolution:

      The SNMP MIB for NetBotz Appliances can be downloaded from the NetBotz Appliance itself by accessing the following URL:

      For version 2:
      https://ip_address_of_appliance/netbotzv2.mib

      For version 3:
      https://ip_address_of_appliance/netbotzv3.mib


      Show More