Quantcast

Cable Management Fixing Accessories, 20mm, Zinc Plated Half Saddle, Fixing Nail

Cable Management Fixing Accessories, 20mm, Zinc Plated Half Saddle, Fixing Nail

Cable Management Fixing Accessories, 20mm, Zinc Plated Half Saddle, Fixing Nail

Item Number: 180N20

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Surface treatment

zinc plated

Sustainable offer status

Green Premium product

Physical

Length

50 mm

Width

19 mm

Height

22 mm

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110719EN

Material

Material

steel

Others

Diameter

20 mm

Package 1 Weight

15 g

Package 1 Height

24 mm

Package 1 width

19 mm

Package 1 Length

50 mm
Show all specifications

Frequently Asked Questions

hide show

Are the Clipsal Conduit Clips available in Electric Orange?

No, they are only available in grey.

This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

Disconnecting and Reconnecting a Configured RS232-Based Sensor or Output Control Device Can Cause Device Settings to be Lost

Issue:

Disconnecting and Reconnecting a Configured RS232-Based Sensor or Output Control Device Can Cause Device Settings to be Lost

Product Line:

NetBotz

Environment:

NetBotz and RS232 sensor connections

Cause:

Settings associated with RS232-based sensors or output control devices may not be preserved if the device is disconnected and then reconnected.

Resolution:

Once you have connected and configured settings for an RS232-based sensor or device, do not disconnect or relocate this device unless you are prepared to reconfigure the device.
 

Will the NetShelter SX leveling feet support the full weight of the cabinet and its contents?

Issue:
Can the full weight of the NetShelter cabinet rest on the leveling feet?
 
Product Line:
NetShelter SX
 
Environment:
All versions and serial ranges.
 
Cause:
Cabinets are leveled using the leveling feet so  they need to bear the full weight of the cabinet and it's contents. (static load rating)
 
Resolution:
Yes, the leveling feet can support the cabinet up to the rated static load rating of the cabinet.  
FAQ FA158656 also contains information regarding shipping load, dynamic load and static load ratings.
 

Common mode filter for bearing current reductions for the ATV600 and ATV900 drives frame size four drives?

Issue:
Filter for bearing current reductions for the ATV600 and ATV900.

Product Line:
ATV600 and ATV900 drives frame size 6

Environment:
All 

Cause:
Filter for bearing current reductions

Resolution:
The part number is VW3A5504 and its value of inductance is 180.0 uH

What are the battery replacement options for the Smartcell battery pack?


Issue

What are the battery replacement options for the Smartcell battery pack?


Product Line

Matrix UPS


Environment

Matrix UPS with SMARTCELL battery packs


Cause

APC has discontinued the SMARTCELL battery pack due to lack of availability of unique parts required to build it.


Resoluiton

In order to continue to support the use of the Matrix battery pack, APC has teamed up with Coastal Business Machines, a certified pre-owned partner, to offer refurbished sales and service of the SMARTCELL battery packs.

Options for replacing the SMARTCELL battery pack

CoastTec is the only authorized refurbisher of the SMARTCELL. They offer 2 options for customers looking to continue using the Matrix-UPS system.

Option 1: Purchase a refurbished SMARTCELL pack, which includes return shipping and disposal of the old battery pack (if applicable).

Option 2: Send your existing SMARTCELL pack into CBMs service center for reconditioning. This option also includes inbound shipping of the old battery pack.






 

PME 9.0 Fails at Verify Databases Step

Issue:
During the install for PME 9.0 user gets error at Verify Databases step. This is shown in the picture below. 


The Installation Log contains the following error:
""END OF POST-DEPLOYMENT STAGE" was NOT found in C:\Program Files (x86)\Schneider Electric\Power Monitoring Expert\Database\Diagnostic\ION_Data_Upgrade.log" 

The ION_Data_Upgrade.log file contains the following:
Changed database context to 'master'.
Creating ION_Data...
Msg 5123, Level 16, State 1, Server VWMERION01P\ION, Line 1
CREATE FILE encountered operating system error 5(Access is denied.) while attempting to open or create the physical file 'C:\Program Files (x86)\Schneider Electric\Power Monitoring Expert\Database\ION_Data.MDF'.
Msg 1802, Level 16, State 4, Server VWMERION01P\ION, Line 1
CREATE DATABASE failed. Some file names listed could not be created. Check related errors.

Product:
PME 9.0


Resolution:
Add the windows user running the installer to the Schneider Electric -> Power Monitoring Expert folder with full control. This can be done by right clicking on the folder and going to Properties -> security. 
 