sock swt sing skirt lighting

Single Switched Socket Skirting Mount Lighting

Catalogue Number: 16L
sock swt sing skirt lighting
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Actuator
  • switch
  • rocker
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      plastic
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      14 mm
      Length
      98 mm
      Width
      45 mm
      Fixing center
      78 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133:approval number S/1
      • Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN
        Circularity Profile
        N/A

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • CAD Files and Packs

        • Technical Data Catalogues

        • Installation Instruction

        • Specifications

        • Certificates (MSDS)

        Frequently Asked Questions

        hide show

        What is the maximum number of point APS_SENSORS that a VAMP 321 or VAMP 221 can monitor?

        Issue
        User needs to know the maximum number of APS_SENSORS that a VAMP 321 or VAMP 221 can monitor

        Product Line
        VAMP 321
        VAMP 221

        Environment
        I/O units

        Resolution
        The VAMP 321 and VAMP 221 can monitor a maximum of 16 modules.
        With a VAM 10L or VAM 12L module you can monitor a total of 160 APS_SENSORS.

        Are there system words in the M340 that indicate IO health?

        System words 160 through 167 (%SW160 - %SW167) provide health status of M340 racks 0 through 7. 0 indicates an IO fault. 1 indicates correct operation of the IO module.


        Compatible I/O units for VAMP 221

        Issue
        User needs to know which I/O units are compatible with VAMP 221

        Product Line
        VAMP 221

        Environment
        I/O units

        Resolution
        The following I/O units are compatible with VAMP 221. Details for each unit are provided below.

        • VAM 12L accommodates up 10 arc APS_SENSORS, 3 APS_SENSORS have dedicated trip outputs
        • VAM 12LD accommodates up 10 arc APS_SENSORS, 3 APS_SENSORS have dedicated trip outputs
        • VAM 10L accommodates up 10 arc APS_SENSORS
        • VAM 10LD accommodates up 10 arc APS_SENSORS
        • VAM 3L accommodates up to 3 fiber loops
        • VAM 3LX accommodates up to 3 fiber loops with sensitivity adjustment
        • VAM 4C accommodates up to 3 current transformers
        • VAM 4CD accommodates up to 3 current transformers

        Is there a replacement for 4RCBE116/30Q Quicklag 16A RCBO?

        Unfortunately not,  we do not have a replacement for 4RCBE116/30Q Quicklag 16A RCBO.

        What is the part number of the mounting block to suit 31/3VX, 162 x 115mm blank switch plate?

        Unfortunately we do not have a mounting block  to suit 31/3VX, large format blank switch plate.

        How can you convert LV429550 to 160 amps?

        Can a PDL 955RW handle 15A

        Yes, it is rated up to 16A

        What is the amperage for a PDL 626VC2

         It is 16A

        What does 20A/16AX stand for Saturn 60PBL

        It means  20A incandesent, 16A fluro

        What is the part number for a Schneider, 60 pole, indoor DB with 160 amp main switch?

        The part number for a Schneider, 60 pole, indoor DB with 160 amp main switch is an MB260E31.

        What is the part number of the mounting block to suit the skirting mount, single outlet 16?

        The part number of the mounting block to suit the skirting mount, single outlet 16 is 47.
        For further details, please refer to the below link:
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=16
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=47

        User-added image
        User-added image

        What is the code for a 600 series dimmer that has a minimum Load of 16W

        Use a PDL654PBM - Push Button Universal Dimmer Module.
        This has a minimum load of 10W

        User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.

        Issue:

        User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.

        Product Line:

        NetBotz
        InfraStruxure Central

        Environment:

        Netbotz SNMP v3

        Cause:

        SNMP version 3 requirements

        Resolution:

        v3 informs only work under certain circumstances.

        md5/des user/password must be 8-15 characters
        md5/aes user/password must be 8-15 characters
        sh1/aes user/password must be 16+ characters
        sh1/des user/password must be 16+ characters

        for md5 the user name and password only work if they are between 8-15 characters.
        for sh1 the user name and password only work if they are >16 characters.

        Osisense XU - Ecolab certificate of compatibility between Ecolab hygiene products and Telemecanique Food and Beverage processing series photo-electric sensors XUK*S rated IP69K

        Please find attached our Ecolab certificate of compatibility between the Ecolab hygiene products (P3-topax for example) and Telemecanique Food and Beverage processing series photo-electric sensors XUK*S rated IP69K, and using stainless steel AISI 316L. Such sensors are sold under the references summarized into the following application leaflet Osisense XUKS.
        https://download.schneider-electric.com/files?p_File_Id=682842640

        What does the 16A & 6AX mean on the 600RM?

        It means the relay module can switch a load of up to 16A resistive or a 6A fluorescent load.

        VAMP 10L module showing error light

        Issue
        After connecting a VAMP 10L (VAM10LSE) module to a VAMP 321 the error light is illuminated.

        Product Line
        VAMP 321
        VAMP ARC Flash Modules

        Cause
        The VAMP module must be configured to talk to the VAMP 321. Until this communication connection is established the VAMP 10L module will be in an error status. (This is also for any other ARC Flash Module)

        Resolution
        Connect to the VAMP 321 using the VAMPset software. Navigate to the ARC Protection screen, then click on the Install arc sensors and I/O units > select install, then write the changes to the VAMP 321. The VAMP 321 will locate all I/O devices along with any connected sensors.

        VAMP 321 arc flash sensors no longer functions after connecting a VAMP 10L module

        Issue
        After connecting a VAMP 10L module to the VAMP 321 relay the VAMP 321 arc flash sensors no longer triggers a trip.

        Product Line
        VAMP 321
        VAM10L

        Cause    
        This issue may be caused by connecting the VAMP 10L module to the VAMP 321 incorrectly.

        Resolution
        Verify that the communication port on the VAMP 321 matches that on the VAMP 10L. If they do not match correct this then reconfigure the connection under the ARC Protection screen within VAMPset and write these changes to the VAMP 321. Finally confirm functionality.

        What is the fluoro rating for a 600 Series mech

        The rating is 16A

        Do PDL do a relay mech

        Yes, it is a PDL 600RM with a 16A resistive rating

        What does the 16AX mean on the PDL 681MT16WH

         It means it has a 16A fluro rating

        What is the part number for the 48 Poles IP42 Metal Distribution Board with 160 Amps Main Switch?

        The part number for the 48 Poles IP42 Metal Distribution Board with 160 Amps Main Switch is "MB248D31"


         

        What is the part number for the 4 Pole NSX160H Breaker with 160 Amps Micrologic 2.2 Trip Unit?

        The part number for the 4 Pole NSX160H Breaker with 160 Amps Micrologic 2.2 Trip Unit is "LV430800"

        https://www.schneider-electric.com.au/en/search/LV430800

         

        What is the purpose of MBP_MSTR FC 16?

        Unity Pro XL V6.0 introduced MBP_MSTR FC 16. This function code allows the user to change the log in status of an ethernet port. In cases where you are unable to connect to a Quantum PLC because the ethernet port is seen as " Already logged in" this FC will prove useful. MBP_MSTR FC 16 will allow you to change the port status to "logged off" and allow the Unity user to log in.
        This would be preferable to using FC 10 (Reset Option module) or performing a power cycle of the PLC.
        There are minimum requirements that the user must meet in order to use MBP_MSTR FC 16. 140NOE77101 minimum firmware version....4.9
        140NOE77111 minimum firmware version....5.0
        140CPU65x xx minimum copro firmware version 3.5


        Legacy KB System (APS) Data: RESL207500 V1.0, Originally authored by DaSo on 02/24/2012, Last Edited by DaSo on 02/24/2012
        Related ranges: Unity Pro - SoCollaborative software

        What is the part code for INS switch with an escutcheon for the INS100

        No there is no escutcheon for the INS40 - 160 range

        What is the maximum motor cable length for an ATV312?

        Issue:
        What is the maximum cable distance from an ATV312 drive to the motor?

        Product line:
        ATV312, Altivar 312, ATV320, Altivar 320

        Environment:
        All models

        Cause:
        n/a

        Resolution:
        The ATV312 shows that an output filter or choke is required for any cable distance between the drive and motor exceeding 164 feet (50 meters).  Above 164 feet, there is a change with shielded vs non-shielded.

        Shielded cables
        From 164 feet to 330 feet (100 meters) you can use the LR filter cell or a motor choke.

        Unshielded cables
        From 164 feet to 660 feet (200 meters) you can use the LR filter cell or a motor choke.
         

        What is the difference between the 8020SCP423 and 8020SCP424 SY/MAX controllers?

        The only difference between the 8020SCP423 and 8020SCP424 SY/MAX controllers is the size of their user memory. The 8020SCP423 has 8K of RAM. The 8020SCP424 has 16K of RAM.

        With led strip light - how many lengths can be run off one driver ?

        As per the catalogue  lsth050wh is supplied with a 16W driver. The LED strip kit has 4.8W/m. So theoretically when the strips are connected in series, 3.3 metres can be run off a driver.
         

        What are the Parts required to make up an NSX250F Breaker with Micrologic 2.2 Trip Unit 160 Amps?

        We can make it up with following two items:

        Part number LV431403 - NSX250F Basic Frame
        Part number LV430470 - Micrologic 2.2 Trip Unit 160 Amps

         

        What is the part number for Switchboard with 160 amp main switch and 36 pole?

        What is the part code for a 2P 16A 6kA C-curve circuit breaker

         The part code is 25817

        What is the code for a 10kA 16A 1p C Curve MCB?

         The code is A9F54116

        What is the part code for the PDL Modena standrd (S2) 16A module

        PDL881M16S

        What is the part number for a 5pin 16A 56 series socket?



        PDL56SO516CEELEGY

        How to increase the number of available serial connections in ION Setup above 16?

        Issue
        When attempting to connect to a serial device in ION Setup a user receives the message: ‘Serial port not available’.
        Product Line
        ION Setup
        Environment
        ION Setup Serial Connections
        Cause
        By default ION Setup supports 16 serial connections and 240 TCP connections. (TCP connections are defined as sites where one can have, say 10 Ethernet devices, connected to a single Ethernet site which will not be counted as 10 TCP connections).
        Resolution
        This default division between serial and TCP connections can be controlled by modifying a setting located in the IONSETUP.INI file. Please change the ‘SerialPorts’ to the desired number from 16. Save the change before exiting the file.

        You can locate the directory that contains the IONSETUP.ini file by opening ION Setup and selecting "Tools -> Options -> Directories"   
        The "Config Directory" file path is where the IONSETUP.ini file is located.
         
        Example:
        [Communications]
        SerialPorts=16
        UpgradeThrottling=1

        Change the value from 16 to 17 to gain an additional serial port.
        [Communications]
        SerialPorts=17
        UpgradeThrottling=1
         
        Please note, the serial port number increment will take place in expense of TCP ports. So, if we increase the serial connections to 17, there will be 239 TCP connections available.

        What is the part number for a 50kA NSX400 C/B with micrologic 2.3 unit with trip range - 160 - 400amps?

        The part number for a 50kA NSX400 C/B with micrologic 2.3 unit with trip range - 160 - 400amps is - LV432693

        For further information , visit link below:-
        https://www.schneider-electric.com.au/en/search/LV432693
        User-added image

        What do the green lights on the VAMP 10L module indicate

        Issue
        There are solid green lights on the VAMP 10L module, what do these indicate?

        Product Line
        VAMP 321
        VAMP 221
        VAMP ARC Flash Modules

        Resolution
        The solid green lights indicate that the attached arc flash sensor is connected and is functioning properly. If the light is not illuminated this indicates an issue with the wiring to the arc flash sensor or an issue with the sensor itself.  

        Note:   This is the same for any VAMP ARC Flash Module.

        Is there available a 160A 3p mcb the same depth as a C120

         No - for 160 , will need to use NSX160, depth = 126mm
        MCB maximum size 125A

        What is the part code for a 16A Relay Module?

         The PDL600RM is rated 16A resistive (6A inductive) and has a NO & NC contact. It is a 600 series module so can be mounted in a grid plate, but doesn't have to be as there is no built in indication as to the state of the contacts.

        Do you do a 16A B curve RCBO?

        No, unfortunately we only do C curves in the combination breakers.

        For further information please visit https://www.clipsal.com/Trade/search-results?q=rcbo

         

        What is the difference between the 8020SCP424 and the 8020SCP444 SY/MAX controllers?

        The difference between the 8020SCP424 and 8020SCP444 SY/MAX controllers is the memory type utilized. Both units have 16K of user RAM; however the 8020SCP444 also offered 11K of nonvolatile memory for program storage on UVPROM.

        Can I still get a WIBM550R?

        No, unfortunately the WIBM550R is no longer available.

        The replacement is the 56AI550.

        Some of the key features are:
        • 5 round pins
        • 204 mm Height x 101 mm Width x 165 mm Depth
        • 10 - 16 mm conductor terminal
        For further information please visit https://www.clipsal.com/Trade/search-results?q=56ai550
         

        What is the part number of the mounting accessories to suit 50X0CTC3, 6.4" colour touch screen without fascia?

        The part number of the mounting accessories to suit 50X0CTC3, 6.4" colour touch screen without fascia are:
        Wallbox (External dimensions: 224 x 167 x 68mm) - 5000CTCWB
        Nail Bracket - 5000CTCNA
        Gyprock Bracket - 5000CTCRM
        For further information please visit:
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=5000CTCWB
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=5000CTCNA
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=5000CTCRM
         

        What are the minimum and maximum cable specifications for Remote I/O ( RIO )?

        Maximum drop length is 164 feet.
        Minimum drop length is 8.5 feet.
        Maximum trunk length is 8400 feet using RG11 and 4600 feet using RG6.
        Maximum overall attenuation for the network is 35 db.
        Minimum distance between taps is 8.5 feet.
        Minimum distance between the RIO head and the self terminating "F" adapter is 18 inches.
        Minimum distance between the self terminating "F" adapter and splitter 8.5 feet.


        What is the part code for a 5 pin socket for a generator to suit PKY Series 16A

        Not available in NZ rewire with 56 series

        What are the specifications for a PDL 573 pull cord ceiling switch ?

        Plate size:  66mm diameter
        Mounting Centres: 50mm
        Rated at 230V - 240V a.c.  16A resistive, 16A inductive   8AX fluorescent
         

        Is the PDL955 16A or 10A as the pocket book states

        The RCD itself has a max rating of 16A.  However this product only comes with 10A rated plug and socket attached.

        Is there a 16A switch mech to suit the Saturn series ?

        Yes - the standard saturn mechs (60PB) are rated at 16AX/20A

        What is the replacement for CCT15837?

        CCT15838 - Prog. time switch 16A IHPplus 1C 18 mm. This only has 1 N/O contact.

        What is the alternative Acti 9 part code for the discontinued Multi 9 24674?

        The alternative Acti 9 conversion is the A9F45316   3 Pole 16A 6kA MCB 

        Is there a 32A 7 pin plug in the PDL 56 Series?

        No. -  The 56 Series plugs only come with 16A or 20A 7 pin plug, as do the sockets.
        Show More