box wall deep 1g wide s/nut

Mounting Accessories WAll Boxes Metal, Poured Concrete, 1 Gang, Deep Wide

Catalogue Number: 164
box wall deep 1g wide s/nut
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
Series 164
Product brand
Clipsal
Shape
rectangular
Number of gangs
1 gang
Cable entry number
14
Material
steel
Surface treatment
electro-galvanized
Length
97 mm
Width
56 mm
Depth
58 mm
Location of connection
rear
Sustainable offer status
Green Premium product
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
ENVPEP110719EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Product Environmental

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the maximum motor cable length for an ATV312?

Issue:
What is the maximum cable distance from an ATV312 drive to the motor?

Product line:
ATV312, Altivar 312, ATV320, Altivar 320

Environment:
All models

Cause:
n/a

Resolution:
The ATV312 shows that an output filter or choke is required for any cable distance between the drive and motor exceeding 164 feet (50 meters).  Above 164 feet, there is a change with shielded vs non-shielded.

Shielded cables
From 164 feet to 330 feet (100 meters) you can use the LR filter cell or a motor choke.

Unshielded cables
From 164 feet to 660 feet (200 meters) you can use the LR filter cell or a motor choke.
 

What are the minimum and maximum cable specifications for Remote I/O ( RIO )?

Maximum drop length is 164 feet.
Minimum drop length is 8.5 feet.
Maximum trunk length is 8400 feet using RG11 and 4600 feet using RG6.
Maximum overall attenuation for the network is 35 db.
Minimum distance between taps is 8.5 feet.
Minimum distance between the RIO head and the self terminating "F" adapter is 18 inches.
Minimum distance between the self terminating "F" adapter and splitter 8.5 feet.


What is the maximum motor lead length you can run the ATV320 drive without a load reactor?

Issue:
What is the max cable length you can run the ATV320 drive without a load reactor?

Product Line:
Altivar 320

Environment:
All

Cause:
Motor cable length distance without a load reactor. 

Resolution:
The ATV320 drive can run up to 164 feet without load reactor.  
You can go up to 328 feet with shielded cable or up to 656 feet with an unshielded cable.
See the table in the attachment.

Are electrical cabinet keys Number 144 available?

Yes the key number 144 is available as a GAEL product, code is DK1. C/W cam lock and 2 keys.

What is the 154 that suits the Slimline range?

The 154 to suit the Slimline range is the 154RM.

Is the socket available for the Clipsal appliance plugs 464 & 465?

No, we don't have an offer for the socket

Are there system words in the M340 that indicate IO health?

System words 160 through 167 (%SW160 - %SW167) provide health status of M340 racks 0 through 7. 0 indicates an IO fault. 1 indicates correct operation of the IO module.


How do I purchase the Hospitality Cards for a PDL626N?

Levco are the suppliers of Hospitality cards +64 9 444 0161

The card is not supplied in the PDL626N pack.

Is there a 154 C-clip that does thicker than 10mm plasterboard/ gyprock?

Yes the 154/1 does plasterboard/gyprock thickness's between 19-25mm.

What is the cut out size for (PDL) 194 panel mount socket with tab terminals

Cut out size 38mm x 32mm

What is the round earth pin version of a PDL 194?

There is no round earth version of the 194 available.

what are the dimensions of the ATV312HU40N4?

Height 184 mm
Width 142 mm
Depth 152 mm

Where can I find the ASB230501 Data Sheet?

Attached is the ASB230501 Data Sheet.

Can I fit 4 sockets on a PDL 144 flush box

Use a PDL 149 and 2 doubles

486d is having issues - have replaced battery but still reads low on screen

It would be recommended to get it serviced / calibrated by Trio Smartcal 1300 134 091

Is there a replacement for 4RCBE116/30Q Quicklag 16A RCBO?

Unfortunately not,  we do not have a replacement for 4RCBE116/30Q Quicklag 16A RCBO.

What is the part number of the mounting block to suit 31/3VX, 162 x 115mm blank switch plate?

Unfortunately we do not have a mounting block  to suit 31/3VX, large format blank switch plate.

What is the part number for a 154 in a 4 gang application?

The part number for a 154 in a 4 gang application is a 2154/4.
Some of the key features are:
  • Mounting brackets
  • 4 gang
  • For plasterboard or hardboard mounting
  • Including 2025V3/30PF
For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=2154/4

 

Why do I get a warning about using a power supply with a 140CRA211xx DIO Adapter?

Title
140CRA211xx DIO Adapter power supply warning
 
Issue
140CRA211xx DIO Adapter power supply warning
 
Product Line
Quantum.
 
Environment
Unity
 
Cause
N/A
 
Resolution
 The purpose of the Warning, is because the 140CRA211xx DIO Adapter has its own built in power supply.
You are cautioned to "DO NOT WIRE THE DIO ADAPTER POWER CONNECTOR WHEN BEING USED THIS WAY"
The two power supplies it can be used with are the 140 CPS 114 00 & 140 CPS 124 00. When the 140CRA211xx DIO Adapter is used with an 8 amp power supply is  will consume approximately 0.5 amps. 
 

Where in the 2014 PDL Pocketbook can I find the BALS Product?

PDL page 76 and 154

What are the dimensions of the PDL194 socket?

Height = 41.8 mm
Width = 48.2 mm
Cutout of 38x32 ​
 

How can you convert LV429550 to 160 amps?

Can a PDL 955RW handle 15A

Yes, it is rated up to 16A

What is the amperage for a PDL 626VC2

 It is 16A

What does 20A/16AX stand for Saturn 60PBL

It means  20A incandesent, 16A fluro

What is the part number for a Schneider, 60 pole, indoor DB with 160 amp main switch?

The part number for a Schneider, 60 pole, indoor DB with 160 amp main switch is an MB260E31.

Are spare keys available for DK1

 Not available as a spare part.  You will need to buy a new lock (which comes with 2 spare 144 keys)

What is the part number for a 3P 200amp front wired main switch

T200FA-BK this comes with cover
 
PDL Book page 124 (2014)

What is the part number of the mounting block to suit the skirting mount, single outlet 16?

The part number of the mounting block to suit the skirting mount, single outlet 16 is 47.
For further details, please refer to the below link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=16
https://www.clipsal.com/Trade/Products/ProductDetail?catno=47

User-added image
User-added image

What are the maximum IO counts for the M251 using the TM3 Expansion modules?

For discrete IO modules, you can have up to 488 digital IO counts.
For Analog IO modules, you can have up to 114 analog IO counts.

What is the code for a 600 series dimmer that has a minimum Load of 16W

Use a PDL654PBM - Push Button Universal Dimmer Module.
This has a minimum load of 10W

User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.

Issue:

User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.

Product Line:

NetBotz
InfraStruxure Central

Environment:

Netbotz SNMP v3

Cause:

SNMP version 3 requirements

Resolution:

v3 informs only work under certain circumstances.

md5/des user/password must be 8-15 characters
md5/aes user/password must be 8-15 characters
sh1/aes user/password must be 16+ characters
sh1/des user/password must be 16+ characters

for md5 the user name and password only work if they are between 8-15 characters.
for sh1 the user name and password only work if they are >16 characters.

What wall clips are suited to the BSL range?

You can use the 154 provided you allow a 10mm gap.

What does the 16A & 6AX mean on the 600RM?

It means the relay module can switch a load of up to 16A resistive or a 6A fluorescent load.

What is the fluoro rating for a 600 Series mech

The rating is 16A

Do PDL do a relay mech

Yes, it is a PDL 600RM with a 16A resistive rating

What does the 16AX mean on the PDL 681MT16WH

 It means it has a 16A fluro rating

Timeout behavior of 140 DDO 364 00

Goals and Symptoms

The purpose of this resolution is to inform the user about an unexpected Timeout behavior of the Quantum Output module 140 DDO 364 00.

Facts and Changes

Quantum Output modules default in case of Timeout of communication to a PLC in general is Set to Zero.
Due to an incorrect default parameter of the 140 DDO 364 00, the Timeout behavior is Hold Last Value.

Affected Concept versions: Concept 2.2
Concept 2.5SR1
Concept 2.5SR2
Concept 2.6SR1


To change the Timeout behavior, the user has to open the Module Parameter screen and has to leave it by the OK button. To leave it by the Cancel button will not change the Timeout behavior.
 

Causes and Fixes

The Timeout default will be corrected with Concept 2.6SR2


Legacy KB System (APS) Data: RESL161741 V1.0, Originally authored by on , Last Edited by on
Related ranges: Concept

How many Clipsal 90 degree sweep bends (247/32-GY )come in a box ?

Ten in a box  (clipsal page 104  - 2014 Pocket Book)

What is the part number for the 48 Poles IP42 Metal Distribution Board with 160 Amps Main Switch?

The part number for the 48 Poles IP42 Metal Distribution Board with 160 Amps Main Switch is "MB248D31"


 

What is the part number for the 4 Pole NSX160H Breaker with 160 Amps Micrologic 2.2 Trip Unit?

The part number for the 4 Pole NSX160H Breaker with 160 Amps Micrologic 2.2 Trip Unit is "LV430800"

https://www.schneider-electric.com.au/en/search/LV430800

 

What is the purpose of MBP_MSTR FC 16?

Unity Pro XL V6.0 introduced MBP_MSTR FC 16. This function code allows the user to change the log in status of an ethernet port. In cases where you are unable to connect to a Quantum PLC because the ethernet port is seen as " Already logged in" this FC will prove useful. MBP_MSTR FC 16 will allow you to change the port status to "logged off" and allow the Unity user to log in.
This would be preferable to using FC 10 (Reset Option module) or performing a power cycle of the PLC.
There are minimum requirements that the user must meet in order to use MBP_MSTR FC 16. 140NOE77101 minimum firmware version....4.9
140NOE77111 minimum firmware version....5.0
140CPU65x xx minimum copro firmware version 3.5


Legacy KB System (APS) Data: RESL207500 V1.0, Originally authored by DaSo on 02/24/2012, Last Edited by DaSo on 02/24/2012
Related ranges: Unity Pro - SoCollaborative software

What is the part code for INS switch with an escutcheon for the INS100

No there is no escutcheon for the INS40 - 160 range

Cannot connect to Sepam with SFT2841 V16.4 and I have other Schneider Electric software using the Modbus Driver

Issue
Cannot connect to Sepam with the SFT2841 software

Product Line
Sepam series 20
Sepam series 40
Sepam series 80

Environment
SFT2841 software
Windows 10
Windows 7

Cause
With the SFT2841 software version V16.4, a certain version of the Schneider Electric Modbus Driver is included with the installation package. If it is necessary to troubleshoot the Modbus Driver installation, some additional work may be required.

An issue may arise in some cases because there are other software applications developed by Schneider Electric that use the same Modbus Driver component as the SFT2841 software, and in some cases they may use different versions of this component compared to SFT2841.

Resolution
Please refer to FA279049 for initial steps to troubleshoot the connection to the Sepam unit

If your installation of the Sepam SFT2841 software V16.4 has completed without any error messages, but you still have problems connecting to your Sepam relay, you can try the following procedure.
  1. Access Windows Control Panel > Programs and Features > locate the DriverManager X64 and Modbus Driver X64   
  2. Un-install the SFT2841 software
  3. Manually un-install the DriverManager X64 and Modbus Driver X64 identified in Step 1
  4. Reboot your computer/laptop
  5. Run the SFT2841 V16.4 installer again.  Alternatively, you can also use the BOX link below to download the Schneider Modbus Driver suite, which is current as of December 2018.
    • https://schneider-electric.box.com/s/xt2cb9cxjx3ju8aoau45atbjtk6unqvu
    • After a successful installation, one should see that the Modbus Driver has been installed again, and this version should be compatible with SFT2841
    • Internet access maybe needed for the DriverManager X64 to be updated to the computer/labtop
  6. With your PC connected to the Internet, update the Sepam Serial Port driver through Windows, as shown in the image below.  Be sure that you wait until Windows has finished updating your Sepam Serial Port driver.
  7. One should now be able to connect to your Sepam device.
Please be aware that other Schneider Electric software that uses this Modbus Driver may not work after following this procedure. The standard practice for Schneider is to ensure compatibility of the latest Modbus Driver version with all current software platforms.  So, normally a new version of both SFT2841 and your other Schneider program (e.g., PLC programming software) should be released later with a Modbus Driver version that is compatible.
 

Please contact the Sepam Technical Support if you are still having problems connecting to your relay.
For the latest version of SFT2841 please refer to FA180051.

What is the difference between the 8020SCP423 and 8020SCP424 SY/MAX controllers?

The only difference between the 8020SCP423 and 8020SCP424 SY/MAX controllers is the size of their user memory. The 8020SCP423 has 8K of RAM. The 8020SCP424 has 16K of RAM.

With led strip light - how many lengths can be run off one driver ?

As per the catalogue  lsth050wh is supplied with a 16W driver. The LED strip kit has 4.8W/m. So theoretically when the strips are connected in series, 3.3 metres can be run off a driver.
 

What are the Parts required to make up an NSX250F Breaker with Micrologic 2.2 Trip Unit 160 Amps?

We can make it up with following two items:

Part number LV431403 - NSX250F Basic Frame
Part number LV430470 - Micrologic 2.2 Trip Unit 160 Amps

 

What is the part number for Switchboard with 160 amp main switch and 36 pole?

Addressing and length of the cam table in CSY84 and 164

Goals and Symptoms

Additionals informations for the management and the addressing of the profils cams tables in CSY84 and 164.

Causes and Fixes

Informations on the parameters of the adjust mode for a cam profil or corresponding parameters of the TRF_RECIPE for cam profil.

· Address table: (%MW or %KW)
Designate the first address of the cam table. Must be always an even value.

· Length for a transfer M+S (Master and Slave):
The tables M and S must be adjacents. The M table must be always before the S table and it's advised to manipulate the whole tables M and S. Avoid to manipulate for example the master table and a part of the slave table.

For a M+S transfert the value to put in the parameter length :
If N pts = the dots curve number put in the configuration
=> Length = N x 4


Nota:
The last occupied address is:
Address table + Length - 2
The first next available address is:
Address table + Length

Example:
Address table = %MW2000
Length = 19996
2000+19996-2=21994
So:
The master and then slave tables begin at %MF2000 and finish at %MF21994.
Next available even address = %MW21996.


· Length for a transfer M or E
The M and S tables are not obligatorily contiguous. It isn't mandatory to have the master table before the slave one.
It is possible to handle all or a part of the table. But always start from the first address ( of the master or slave table ).


If N dts = the dots number of the curve declared in configuration
=> Length = N x 2
With 2 <length< ( N x 2 )
Example:
If 4999dts we can read or write from 1 to 4999dts => 2 <Length< 9998

Nota:
The last occupied address is:
Address table + Length - 2
The first next available address is:
Address table + Length

Example:
Address table = %MW0
Length = 9998
0+9998-2=9996
So:
The master or slave table begin at %MF0 and finish at %MF9996.
Next available even address = %MW9998


Legacy KB System (APS) Data: RESL179776 V1.0, Originally authored by JeCa on 09/18/2006, Last Edited by JeCa on 09/18/2006
Related ranges: Modicon Premium

- Does the 30USBCM fit into 2025XA and C2025XA

Yes it will fit into 2025XA / C2025XA, with the following mounting hardware only: 154, 154RM, 154/1, 155NAR, 155VNAR, 155PRM, 156/2, 157, 164, 449A. Will not fit SC2025XA / 25XA. ( Also please note that it will need to be placed into plate in vertical configuration)
For more information on the 30USBCM please visit the Clipsal web site or click  link provided .https://www.clipsal.com/Trade/search-results?q=30usbcm
Show More