What is the part number for the 12 and 16 way metal Clipsal plates
Part number for the 12 way - 12/30/162/3-WE and 16 way - 16/30/162/4-WE
What is the part code for a 16 aperture plate and box to take 600 series mechs?
PDL534B16
PDL534P16S
Do we still have 16mm, Transparent, rigid, conduit?
No we do not.
What is the password format for the Quantum NOE modules?
The password can be up to 16 non-extended ASCII characters.
How many Unity Pro MBP_MSTR Blocks can run at one time over Etherent using a 140NOE77101 module?
The limitation is 16. Should you program more than 16 without sequencing, the PLC will only process 16 at a time and progress through the others as the blocks complete.
Is there an alternative for a power vertical 16 way junction box 3106PV16WJB?
Unfortunately, the 16 way junction box power vertical 3106PV16WJB has been discontinued and there are no alternatives.
For more information on our product range please visit
https://www.clipsal.com/Trade
Is there a neutral bar which has 14 to 16 holes?
Yes we have a Neutral bar with both 14 and 16 holes. The part number for a 14 hole neutral bar is
L14 and The part number for a 16 hole neutral bar is
L16.
Some of the key features for the L14 are :
- Two screw In 8 Tunnel and One Screw In 6 Tunnel
- 2 tunnel, 6.3 mm Diameter accommodate 1 x 16 sq mm cable
- 6 Tunnel, 5.5 mm Diameter accommodate 1 x 16 sq mm cable
- 6 Tunnel, 4.5 mm Diameter accommodate 1 x 16 sq mm cable
- Dimensions: 86 x 57 x 40 mm
- 100A Rated
Some of the key features for the L16 are:
- Two screw in 6 tunnels and one screw in 10 tunnel
- 2 tunnels, 6.3 mm Diameter accommodate 1 x 16 sq mm cable
- 4 Tunnels, 5.5 mm Diameter accommodate 1 x 16 sq mm cable
- 10 Tunnels, 4.5 mm Diameter accommodate 1 x 10 sq mm cable
- Dimensions: 86 x 57 x 40 mm
- 100A rated
For further information please visit
https://www.clipsal.com/Trade/search-results?q=Neutral%20Link
How to join two strings with result more than 16 characters in Unity Pro.
By default the maximum characters allowed for the STRING data type is only 16. It can be increased to 65534 ASCII characters.
For this select the data type as STRING [<size>], where size denotes an unsigned integer (UINT) capable of defining a string between 1 and 65534 ASCII characters.
The result will be displayed in 16 characters only. However, the maximum characters it can contain will be the one defined in it's data type.
Is it possible to configure the SY/MAX model 400 controller to store previous HALT codes?
Yes. Register 8107 is a pointer register to a 16 register stack. If a value is entered in this register, the controller will use that register as the start of a stack of a 16 long stack of the last error codes contained in 8175 (i.e. if a value of 100 is placed in 8107, Registers S100-S115 will contain the last 16 HALT codes generated by the controller).
What is the part number for a keypad with LCD display , and suits the 8 or 16 zone alarm panels?
The part number for a keypad with LCD display , and suits the 8 or 16 zone alarm panels is - 5412KP
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=5412KP
What is the part number for the 7.5 KW complete enclosed DOL Starter with 240V AC Coil Voltage and 12 - 16 Amps Overload?
The part number for the 7.5 KW complete DOL Starter with 240V AC Coil Voltage and 12 - 16 Amps Overload is LE1M35U722 This is the economy model and has no spare parts available.
The more industrial model is the LE1D18U7 which needs the LRD21 12-18A overload added as an extra.
External Fusing Change for 24vdc Momentum I/O Modules
The purpose of this Resolution is to inform users of 24vdc Momentum I/O Bases that the fusing requirement has changed.
Using a 315ma fast blow fuse on a redesigned 24vdc Momentum base may cause the fuse to blow when powered up. Since the 24vdc Momentum I/O bases have been redesigned to meet the new EMC and power hold-up requirements, it was necessary to increase the size of the external fusing.
The external fusing is indicated in the User Manuals as follows. It does not affect the recommended fusing for the I/O power.

The recommended size of the external fuse for all Momentum I/O modules that are powered by 24 VDC, has changed from a 315ma Fast Blow fuse to a 1Amp Slow Blow fuse (Bussmann GDC-1A or equivalent).
The 1A Slow Blow fuse can be used on both new and old versions of 24vdc powered Momentum I/O bases listed below.
DC Discrete Modules
- 170ADI34000 24V DC - 16 Pt Input Module Base
170ADI34000C 24V DC - 16 Pt Input Module Base Coated
170ADI35000 24V DC - 32 Pt Input Module Base
170ADI35000C 24V DC - 32 Pt Input Module Base -Coated
170ADM35010 24V DC - 16 Pt Input/ 16 Pt Output Module Base
170ADM35010C 24V DC - 16 Pt Input/ 16 Pt Output Module Base Coated
170ADM35011 24V DC - 16 Pt Input/ 16 Pt Output - Fast Response Module Base
170ADM35015 24V DC - 16 Pt Input/ 16 Pt Output Module Base - True Low Signals
170ADM39010 24V DC - 16 Pt Input/ 12 Pt Output - Monitored Module Base
170ADM39030 24V DC - 10 Pt Input/ 8 Pt Relay Output Module Base
170ADM39030C 24V DC - 10 Pt Input/ 8 Pt Relay Output Module Base Coated
170ADO34000 24V DC - 16 Pt Output Module Base
170ADO34000C 24V DC - 16 Pt Output Module Base Coated
170ADO35000 24V DC - 32 Pt Output Module Base
170ADO35000C 24V DC - 32 Pt Output Module Base Coated
170ADM85010 10 to 60 V DC - 16 Pt Input/ 16 Pt Output Module Base
Analog Modules
- 170AAI03000 Analog - 8 Ch Differential Input Module Base
170AAI03000C Analog - 8 Ch Differential Input Module Base Coated
170AAI14000 Analog - 16 Ch Single-Ended Input Module Base
170AAI14000C Analog - 16 Ch Single-Ended Input Module Base Coated
170AAI52040 Analog - 4 Ch RTD, Thermocouple, and Mv Input Module Base
170AAI52040C Analog - 4 Ch RTD, Thermocouple, and Mv Input Module Base Coated
170AAO12000 Analog - 4 Ch Output 0-20mA Module Base
170AAO92100 Analog - 4 Ch Output 4-20mA Module Base
170AAO92100C Analog - 4 Ch Output 4-20mA Module Base Coated
170AMM09000 Analog - 4 Ch In/ 2 Ch Out Module Base, w/ 24V DC 4 In/2 Out Digital
170AMM09000C Analog - 4 Ch In/ 2 Ch Out Module Base, w/ 24V DC 4 In/2 Out Digital Coated
170AMM09001 Analog - 4 Ch In/ 2 Ch Out Module Base, w/ 12V DC 4 In/2 Out Digital
Specialty Modules
- 170AEC92000 High Speed Counter Module Base
What is the suspension hook for the 56 Series Mactro connectors
The suspension hook 56SHL fits the MACTRO 32 - 50A connectors, and the 56SHM fits the 16 - 20A connectors (and plugs)
Is there a 269CF-WE but in a bigger size?
No, we only have the 269CF-WE which is 16 - 25mm.
What overload can be used for the LC1D32 contactor @16amps?
either the LRD21, 12 to 18 amps.
Or the LRD22, 16 to 24 amps.
What size entry(s) does the 900SPMB have?
The 900SPMB has four 25 mm x 16 mm trunking entries, one at each side and end.
What part number for a Acti9 3 pole B curve 16 amp device?
The Part code is A9F53316.
Do you do RJ30 24 port mechanisms
No However we can offer a 16 port version. The part number is a RJ30/16UPPU.
What is the thickness of the PDL534P16 16 Gang Stainless steel plate?
The thickness is 1mm.
https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=323
Using Concept what causes an 'Animation must be turned off to download' error message when nothing is animated?
This can be caused by the 16 bit simulator. To correct this turn the 16 bit simulator on and off.
Legacy KB System (APS) Data: RESL164137 V1.0, Originally authored by on , Last Edited by on
Related ranges: Concept
What terminal connector would be used with the Sy/Max 16 point input and output modules?
The Sy/Max 16 point input and output modules terminal blocks are the same part number, 8030-CBP-116. These terminal connectors are supplied with the module.
How many Client TCP/IP connections can the M1E simultaneously have?
Client Paths
The M1 Ethernet controller supports 80 client paths. 64 are dedicated to I/O Scanner and 16 for MSTR. You cannot have more than 16 active MSTRs at any given time.
Each of the 80 client paths can initiate any of the following three MODBUS commands:. Function code 3 for reading 1 to 125 registers from the target, function code 16 for writing 1 to 100 to the target, and function code 23 for writing 1 to 100 registers to the target and reading 1 to 125 registers from the target.
What's the replacement for TSXDSY16R5?
Issue
The TSXDSY16R5 (Modicon Premium Discrete output module with 16 relay outputs) is now out of production. What is its replacement?
Product Line
Modicon Premium PLC I/O Modules
Environment
I/O Equipment
Resolution
The Modicon Premium TSXDSY16R5 Discrete output module with 16 relay outputs is no longer in production.
It's replacement part number is BMXDRA0805. This is a discrete output module with 8 relay outputs (12..24V) for use with the Modicon M340 family of PLCs configured with Unity Pro configuration software.
Is the Compact Interbus S Master 'AS-BBKF-201' a 16 word or 64 word module?
The Compact Interbus S Master Module "AS-BBKF-201" can be setup for either 16 or 64 word. It all depends on what you setup the Dip switch settings for S0 and S1. The Dip switch configuration settings for S0 and S1 are explained in Chapter 11 from the latest Modicon A120 Series I/O Modules User Guide (890USE10900 Version 4.0).
Are there any simulator modules available for the Quantum series?
There are two types of simulator modules available for the Quantum series.
The 140XSM00200 discrete simulator module consists of 16 toggle switches which are used to generate up to 16 binary input signals.
The 140XSM01000 analog simulator module is used for simulating 4-20mA field current loops used with current input Quantum modules.
Legacy KB System (APS) Data: RESL170509 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modicon Quantum
What is the part number for the Twido TWDLMDA20DRT 13 and 16 pin connectors?
The TWDLMDA20DRT connector part numbers are:
13 pin - TWDFTB2T13 (pack of 2)
16 pin - TWDFTB2T16 (pack of 2)
Note: The Twido PLC line is obsolete and the replacement for it is the M221 product line. For more information on this contact your local Schneider office or local distributor.
How many remote device connections are available on the EGX300?
Issue:
User would like to know how many remote connections the EGX300 can support.
Product Line:
EGX300
Environment:
Ethernet Gateways
Cause:
The remote connections only allows for 16 IP individual IP addresses to be entered on the Remote Device Connection section on the webpage of the EGX300

Resolution:
The EGX300 can open connections for up to 16 unique, user-defined remote Modbus TCP/IP devices.
What are the hole sizes in the BP165/7?
The hole sizes in the BP165/7 are as follows:
Dimensions: 100 x 43 x 40mm.
Terminal bar: 16 x 16 x 76mm.
2 tunnels: 9.5mm diameter accommodate 50mm2 cables.
1 tunnel: 8.0mm diameter accommodates 35mm2 cable.
2 tunnels: 7.1mm diameter accommodate 25mm2 cables.
2 tunnels: 5.5mm diameter accommodate 16mm2 cables.
Mounting centres: 71 x 29mm.
How many wires can you install on the Power poles for the LC1D65A contactor?
Issue:
How many wires can you install on the Power poles for the LC1D65A contactor?
Product line:
Tesys D, Everlink
Environment:
LC1D40A LC1D50A LC1D65A
Cause:
Documentation not found
Resolution:
The LC1D40A to LC1D65A Everlink version contactors can use 2 power cables per phase. 1x AWG 16 to AWG 4 plus 1x AWG 16 to AWG 2.
Instruction bulletin attached.
Can I terminate a flexible conduit or other cable gland into the base of the 56 Series Mactro plug or connector
Yes you can, the 56AM25 suits the 16 & 20A and the 56AM40 suits the 32 - 50A plug or connector.
It replaces the locknut and cord clamp that is supplied with the Mactro plugs and connectors.
How many slave RS-485 devices can be supported by the 174CEV30020 MB to MBTCPIP bridge?
The 174CEV30020 can support up to 16 slave serial RS-485 devices in either 2 wire or 4 wire mode.
What replaces the AS-BSIM-216?
Unfortunately there is no offered replacement for the AS-BSIM-216 discrete simulator. The user would instead need to set up their own set of 16 switches and field wiring appropriate to the discrete I/O module being used to perform the same function.
What are the major differences between the SyMax 8030ROM221 and 8030ROM271 output modules?
Both the SyMax 8030ROM221 and 8030ROM271 are 16 point isolated output modules. The Major difference is that the 8030ROM221 has optically isolated outputs and the 8030ROM271 has relay isolated outputs. There are some other specification differences, please refer to the individual module specification sheets.
What is the difference between the Quantum 140DAO84010 and 140DAO84210 modules?
They are both Quantum AC output modules. The difference is the voltage and grouping.
140DAO84010.....24-115 VAC, 16 isolated channels.
140DAO84210.....100-230 VAC, 4x4 grouped channels.
What is the memory consumption in the new Quantum Ethernet I/O system for Ethernet Remote I/O?
400 input words per drop, 400 output words per drop, 16 input Kwords in system and 12 output Kwords in system.
PowerLogic High Density Metering (HDM) Cabinet Installation Guide (8 and 16 meter models)
Product Line
High Density Metering
Environment
Documentation
Resolution
See attached document.
Instruction Bulletin 63230-504-202A3.
How many buttons are available for use on the eDLT?
There are 16 buttons available across 4 pages, the 5th button on every page is used for changing between pages.
The unit can also be configured as a single page, 5 button device.
ETSNZ - How many Modbus TCP Client connections does the ETY4103 support?
There can be up to 64 connections open but, only 16 simultaneous client connections can be running at a time.
If there are no clients, there can be up to 63 server connections opened and 1 will be reserved for listening.
How many Push button transmitters can be connected to the ZBRRA
The Wireless batteryless receiver can take 32 Push buttons (has two channels - takes 16 on each channel).
Do you have an 8 button EDLT C-BUS switch?
No however the 5085 EDLT has 5 buttons. the bottom button can be used as a page button therefore you can have 16 switches on the one switch plate.
What is the part number for a 56 series switch, 16 amps single phase with the key removable in the on and off position?
The part number is PDL56SW2K116LEGY
the '2K' indicates it is Key locked and the key is removable in the on and off position.
Can multiple pushbuttons be assigned to any receiver either ZBR RA or RC?
Up to 32 wireless pushbuttons can be assigned to any single receiver. The Receiver has two channels - 16 Buttons can be assisgned to each channels.