Single Switch Socket Outlet, 250V, 10A, Standard Size, 2 Removable Extra Switch

Single Switch Socket Outlet, 250V, 10A, Standard Size, 2 Removable Extra Switch

Single Switch Socket Outlet, 250V, 10A, Standard Size, 2 Removable Extra Switch

Item Number: 15XX-WE

Retail
$126.93
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE
  • Cream 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Standard Series

Surface finish

glossy

Sustainable offer status

Green Premium product

Physical

Control type

ON/OFF button

Number of gangs

1 gang

Pin number

3

Number of power socket outlets

1

Actuator

  • rocker
  • switch
    • Mounting position

      horizontal

      Fixing mode

      by screws

      Local signalling

      without light indicator

      [Ue] rated operational voltage

      250 V AC

      [In] rated current

      10 A

      Depth

      14 mm

      Length

      115 mm

      Width

      73 mm

      Fixing center

      84 mm

      Standards

    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • EU RoHS Directive

        Compliant

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        Product out of China RoHS scope. Substance declaration for your information

        Environmental Disclosure

        ENVPEP120506EN

        Material

        Material

        PC (polycarbonate)

        Others

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        104 g

        Package 1 Height

        25 mm

        Package 1 width

        118 mm

        Package 1 Length

        71 mm

        Unit Type of Package 2

        BB1

        Number of Units in Package 2

        5

        Package 2 Weight

        0.582 kg

        Package 2 Height

        124 mm

        Package 2 width

        108 mm

        Package 2 Length

        146 mm

        Unit Type of Package 3

        CAR

        Number of Units in Package 3

        100

        Package 3 Weight

        12 kg

        Package 3 Height

        254 mm

        Package 3 width

        348 mm

        Package 3 Length

        445 mm
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • Specifications

        Frequently Asked Questions

        hide show

        What is part number for Optiline 70 skirting duct 155x 55?

        The part number for Optiline 70 skirting duct 155x 55 is a - ISM11450

        For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=ISM11450


        User-added image

        Is the extra switch in the 15X removable?

        Yes, the extra switch in the 15X is removable. Any 230v rated 30 series mec will fit in it's place.

         

        The ION 75xx RTU reads -1 for all external numeric registers and will not save any changes after a register write

        Issue
        User is getting -1 when reading an externa numeric register. The user may notice that any changes to this register will not save

        Product Line
        ION 7550 and ION7500 RTU

        Environment
        ION Framework

        Cause
        The ION 75xx RTU units do not come with predefined framework on the meters. If a module does not exist on the framework, modbus requests will return -1.

        Resolution
        Use ION Setup or ION Designer to create external numeric modules and unlock the registers. Once the module has been created the register will read 0 instead of -1.

         

        Compatibility of PM5100/PM5300 meter hardware with firmware versions

        Product Line
        PM5100
        PM5300

        Environment
        Firmware

        Resolution
        • Firmware revision 2.xx is applicable for PM51/53xx meters with enhanced internal memory.
        • Firmware V2.xx revision is applicable for Hardware version B1. Hardware version is indicated on the Meter labels
        • Firmware version 2.xx is not compatible with firmware version 1.xx.
        • Meters with 1.xx firmware can’t be upgraded with 2.xx firmware.
        Refer to the attached What's New with V02.1x & V02.2x

        Can you invert the CT polarity of the EM35xx series meters?

        Issue:
        The CT's are wired incorrectly for an EM 35xx series meter and a customer would like to correct the issue by inverting the polarity through the meter front panel or software similar to an ION meter.

        Product Line:
        EM35xx series meter

        Environment:
        CT wiring

        Cause:
        The CT's for the meter have been wired incorrectly.

        Resolution:
        The CT polarity is not changeable either from the front panel, software configuration, or register writes so the meter will have to be deenergized and rewired correctly.

        Do ION or Powerlogic meters support EtherNet/IP?

        Product Line
        ION
        PowerLogic

        Environment
        Communication Protocols

        Resolution
        The PM5500 supports EtherNet/IP as of Firmware version 2.5.2.

        *Note: EtherNet/IP is a derivitive of the Common Industrial Protocol (CIP) and should not be confused with the TCP/IP protocol suite. 
         

        What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

        Goals and Symptoms

        What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

        Facts and Changes

        Power Suite and pocket PC

        Causes and Fixes

        IPAQ3900-3800 séries are not supported by version 1.4 of Powersuite it's a mistake in the VVD info 179

        More clearly:

        Powersuite v1.5 works under Pocket PC, Pocket PC2002 and it need a serial link. Don't work for the moment under Pocket PC2002, 2003 and Phone Edition.

        IPAQ 19xx, 22xx, 55xx don't have serial link and Powersuite don't work on it.
         


        Legacy KB System (APS) Data: RESL157483 V1.0, Originally authored by on , Last Edited by on
        Related ranges: Other VVD PRODUCTS

        What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

        Goals and Symptoms

        What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

        Facts and Changes

        Power Suite and pocket PC

        Causes and Fixes

        IPAQ3900-3800 séries are not supported by version 1.4 of Powersuite it's a mistake in the VVD info 179

        More clearly:

        Powersuite v1.5 works under Pocket PC, Pocket PC2002 and it need a serial link. Don't work for the moment under Pocket PC2003 and Phone Edition.

        IPAQ 19xx, 22xx, 55xx don't have serial link and Powersuite don't work on it.
         


        Legacy KB System (APS) Data: RESL157484 V1.0, Originally authored by on , Last Edited by on
        Related ranges: Other VVD PRODUCTS

        Can the Com'X Series have a Publication Time smaller than an hour?

        Unfortunately it is not possible to have a publication time for less than an hour for either the Com'X 5xx or Com'X 2xx series units.

         

        Is there a replacement connector, mounting bracket, or grounding nut for an ION7650 or ION7550?

        Issue
        ION7650/7550 meter is missing one of its connectors

        Product Line
        ION7650 Meter
        ION7550 Meter

        Environment
        Meter installation

        Cause
        A user may want to replace a lost, damaged, or missing connector, mounting bracket, or grounding nut for an ION7650 or ION7550

        Resolution
        There is a part number that can be ordered to replace any lost, damaged, or missing connectors, mounting brackets, or grounding nuts for ION7650 and ION7550 meters.

        Part number FR-75XX-CONN is a spare connector kit containing all connectors, mounting brackets, and grounding nuts for FIVE ION7650 or ION7550 meters.

        NOTE: the connector kit contains all connectors, mounting brackets, and grounding plugs for FIVE ION7650 or ION7550 meters.

        What would cause the error "Flash RAM version mismatch, cannot write" when trying to download to a Quantum PLC using ProWORX NxT?

        Issue
        "Flash RAM version mismatch, cannot write" when trying to download to a Quantum PLC using ProWORX NxT

        Product Line
        Quantum

        Environment
        ProWORX NXT

        Cause
        The most common cause of this error is selecting the wrong "Controller Type" during configuration.

        Resolution
        When configuring a Quantum PLC with ProWORX NxT, you must select the correct executive firmware for the "Controller Type". Below is the Change Controller Type "Pick List". If the Quantum PLC has version 2.XX firmware, you need to select Rev 2 for the PLC Type. "Quantum 113/3 is for version 1.XX firmware" and "Quantum 113/3 REV 2" is for version 2.XX firmware.

        Does PM5300 support BACnet protocol?

        Product Line
        PM5300

        Environment
        Communications

        Resolution
        PM5320, PM5340, and PM5341 support BACnet IP protocol from the firmware version V2.1X and higher with Hardware Version B1.
        Firmware V2.xx is applicable for Hardware version B1. Hardware version is indicated on the Meter labels.
        Meters with 1.xx firmware can’t be upgraded with 2.xx firmware for BACnet support and refer the FA358115 for firmware compatibility.

        The meter supports specific BACnet components and standard objects. The BACnet protocol allows you to:
        • set the out-of-service property of an object to true
        • to write a value to the out-of-service  property for testing

        PM5320, PM5340 and PM5341 meters do not support BACnet MS/TP (BACNet Serial), these meters only support BACNet IP (over Ethernet)
        Show More