Quantcast

Single Switched Socket 10A Light Indicator

White Electric | Single Switched Socket 10A Light Indicator

Single Switched Socket 10A Light Indicator

Item Number: 15LN-WE

Retail
$195.10
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Standard Series

Surface finish

glossy

Physical

Control type

ON/OFF button

Number of gangs

1 gang

Pin number

3

Number of power socket outlets

1

Actuator

  • switch
  • rocker
    • Mounting position

      horizontal

      Fixing mode

      by screws

      Local signalling

      indicator light

      [Ue] rated operational voltage

      250 V AC

      [In] rated current

      10 A

      Depth

      14 mm

      Length

      115 mm

      Width

      73 mm

      Fixing center

      84 mm

      Standards

    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • EU RoHS Directive

        Under investigation

        Material

        Material

        PC (polycarbonate)

        Others

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        0.09 kg

        Package 1 Height

        14 mm

        Package 1 width

        73 mm

        Package 1 Length

        115 mm
        Show all specifications

        Frequently Asked Questions

        hide show

        Unable to input the primary or secondary voltage transformer ratio into VAMP321 Arc Flash Mitigation relay

        Issue: Unable to input the primary or secondary voltage transformer ratio into VAMP321 Arc Flash Mitigation relay using the VAMPSet software

        Cause: Configuration

        Resolution: By default the VT or PT is set to Uo which is for a residual voltage measurement. If a line to neutral or line to line VT is being used, the Voltage measurement mode (available in the SCALING section) must be set to 1LN or 1LL, this change must then be loaded into the VAMP321. Once this is complete you must refresh the view from the device to open the VT primary and VT secondary options. Enter th correct VT ratio and send this change to the VAMP321.

        How to implement MFB (Motion Function Block) functionality for Lexium 05, Lexium 32, Lexium 15 and IclA drives in Unity Pro for M340?

        Goals and Symptoms

        How to implement MFB (Motion Function Block) functionality in a Modicon M340 for Lexium 05, Lexium 32, Lexium 15 and IclA drives in Unity Pro?

        Facts and Changes

        Reference of software used:
        - Unity Pro 4.1 and Unity Pro 5.0.

        - The standard version of the hardware catalog manager (ver 1.0) is included in both UnityPro versions 4.1 and 5.0

        Causes and Fixes

        The following is a step by step procedure on how to implement the MFB (Motion Function Block) functionality in a Modicon M340 for Lexium 05, Lexium 32, Lexium 15 and IclA drives in Unity Pro.

        A . How to Configure the CANopen Slave?

        1, In Unity Pro Project Browser, fully expand the Configuration directory and then double-click on CANopen. The CANopen window appears:



        2. Select Edit / New device. The New Device window appears.


        3. Under Motion&Drives select:

        a. LXM05_MFB for LXM05A drive
        b. LXM32_MFB for Lexium32A and Lexium32M drives. See "B. How to Upgrade the Hardware Catalog" if the LXM32_MFB is not listed.
        c. Lexium15LP_V1_45 for a Lexium 15LP drive or Lexium15MH_V6_64 for a Lexium 15MP drive.
        d. IclA_IFA, IclE_IFA or IclA_IFS for the corresponding IclA drives.

        4. Select Edit / Open Module. If MFB has not already been selected, choose it in the Function area.

        5. You will now be asked to validate your modifications when closing the CANopen window. This completes the implementation of the MFB functionality for the selected drive(s). For Lexium 32 series drives, please follow the procedure listed below to first upgrade the hardware catalog.

        B. How to Upgrade the Hardware Catalog (applies for Lexium 32 drives)
        (Note: All the drives mentioned above are part of the Hardware Catalog Manager version 1.0 except LXM32_MFB)

        1. Open the Hardware Catalog: Start /Program / Schneider Electric / SoCollaborative / UnityPro / Hardware Catalog Manager. The Hardware Catalog Manager window appears:


        2. To upgrade the catalog go to File / Import User Devices and then import the LXM32_MFB.cpxfile. The file is attached to this resolution.


        C. Axis Creation and Configuration
        1. Right-click on the Motiondirectory and then click on the New axis.
        2. Clicking on the New axiscommand will open a dialog box with three tabs.
        3. In the General tab, enter a name, selecta servodrive from the list and a compatible CANopen address
        4 In the Axis Parameterstab, selectthe reference of the servodrive and the minimum version of the servodrives firmware
        5. In the Variables Name tab, enter:a name for the Axis_Ref type variable linked to the servodrive and a name for the Can_Handler type variable linked to the servodrive
        6. Click on OK to confirm the selections.

        D. Availability of Blocks on the Various Servodrives

        Not all blocks are available on all hardware platforms. The blocks available on your Modicon M340 platform with CANopen fieldbus can be found in the following tables:

        .

        For further details please refer to the MFB for Modicon M340 using Unity Pro - Start-up Guide attached to this resolution

        This completes the procedure on implementing the MFB functionality in UnityPro..

        Attachments

        (Removed File URL: 204163_06C2/LXM32_MFB.cpx)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/833f1d1337661839c12577fa0016482f/fl_block_5/0.158?OpenElement&FieldElemFormat=gif) (Removed File URL: 204163_06C2/MFB_for_Modicon_M340_using_Unity_Pro_-_Start-up_Guide.pdf)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/833f1d1337661839c12577fa0016482f/fl_block_5/0.834?OpenElement&FieldElemFormat=gif)


        Legacy KB System (APS) Data: RESL204163 V1.0, Originally authored by TVe on 12/15/2010, Last Edited by TVe on 12/15/2010
        Related ranges: Modicon M340, Lexium 32