socket swt single dp 15a 250v

Single Switch Socket Outlet, 250V, 15A, Standard Size, 2 Pole

Catalogue Number: 15D15
socket swt single dp 15a 250v
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Actuator
  • switch
  • rocker
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      PC (polycarbonate)
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      15 A
      Depth
      14 mm
      Length
      115 mm
      Width
      73 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN
        Circularity Profile
        N/A

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • CAD Files and Packs

        • Technical Data Catalogues

        • Installation Instruction

        • Product Environmental

        • Specifications

        • Case Studies

        • Certificates (MSDS)

        Frequently Asked Questions

        hide show

        What is the part code for a 1P 32A relay

         The part code is 15515

        what is the Acti 9 code for Merlin Gerin 15515?

        A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

        Does the 15725 have daylight savings function

        15725 has been superceded by CCT15837
        CCT15837 has NZ listed for daylight saving

        Is the 15216 DC rated

        The primary voltage 240VAC

        What is the Alternative for the Merlin Gerin 15913?

        A9C15913

        Can the 15013 isolators handle a manual operation under load

         Yes they can

        What is the replacement for 15465 KWH meter?

        Is the 15335 a suitable replacement for the 4TC timer

        Yes it is

        What is the part code for an MG bell transformer

         The part code is a 15216

        For the 15725 programmable timer what is the battery that fits into it?

        CR2032 battery

        What is the part code for a 1P 63Amp dinrail isolator

         The part code is 15013

        What is the part code for the replacement rubber seal for PDL 14/15 Tuff light

        The part code is PDL20/8

        What is the acti 9 equivelant of the 15512

        The part code is A9C30211

        Is there a double pole 15A outlet?

        Yes, the part number is a 2015D15

        Do you have a 15335 Timer in a 12V DC Timer?

        No unfortunately this is unavailable.

        Does the Ritika Circuit breaker 25815 have the same dimensions as the 25823

         It has the same physical size

        What is a 2pole, 6A, C Curve, 6kA circuit breaker

         Part code 25815 Multi 9 - Acti 9 A9F44206

        What is the part code for a sealable cover for mains switch (din mounted) 15013

         The part code is 26975

        Does the 15335 mechanical timer come with memory back up?

        No, this particular device does not have memory back up.

        What is the replacement for the 15151?

        The replacement for the 15151 is part number A9A15151
        see data sheet....https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9A15151
        User-added image

        What is the current replacement for the 15725

        The part number is the CCT15838 the main difference is this has N/O contacts and the 15725 had C/O contacts.
        (See attached data sheet)
         

        Is it possible to test several 755FM units which are all interconnected?

        Hold the test button down for about 10-15 seconds and other smoke alarms on circuit should go off

        Information on Online and On Battery operation of 3:1 Symmetra UPS systems



        Issue

        Where can I find information on the Online and On Battery operation of 3:1 Symmetra UPS systems?


        Product Line

        Symmetra Power Array
        Symmetra LX


        Environment

        3:1 (International) UPS systems only


        Cause

        This document is designed to provide Information on Online and On Battery operation of 3:1 Symmetra UPS systems


        Resolution

        When a Symmetra 3:1 is operating On-Line it is drawing balanced power from all 3 phases, i.e., it is drawing the same current from each of the 3 phases. This is typically 25 amps per phase with a maximum 16KVA load. The 3 phase power is fed to all the Power Modules where it is filtered and converted to single phase and sent to the output. The nominal input voltage range is 380 or 400 or 415.

        (220 x 1.7 = 380; 230 x 1.7 = 400; 240 x 1.7 = 415. Where 1.7 = square root of 3)

        The Symmetra 3:1 will run On-Line for inputs between 290 VAC and 480VAC. The output voltage can be set to either 220 / 230 / 240 VAC at 50 or 60 Hertz.

        If any one of the phases fails, the Symmetra will still operate On-Line but will pull more current from the other 2 phases. In this case it will draw no more than 60 amps per phase . If phase A or B fails, then the PowerView will report "Bypass Out of Range". If phase C fails, there is no notification message on PowerView. You will manually have to check the PowerView and read the input voltages.

        If a second phase fails, then the Symmetra will go to On Battery operation and report "Bypass Out of Range" on the PowerView. Likewise, if all 3 phases fail it will go to On Battery operation.

        When Symmetra 3:1 is On Battery it will provide single phase output power. The output voltage can be set 220 / 230 / 240 VAC. The output frequency can also be set to either 50Hz or 60Hz.

        Please Note: While current is evenly distributed across all three phases while Symmetra 3:1 is on-line, all current will draw from phase 1 if the UPS is in bypass unless the optional Symmetra Bypass Transformer is in use.


        What are the dimensions and the weight on the ATS48C41Y soft starter?

        Issue:
        What are the dimensions and the weight on the ATS48C41Y, ATSC59Y and ATS48C66Y soft starter?

        Product Line:
        Altistart 48 

        Environment:
        ATS48C41Y ATSC59Y ATS48C66Y

        Cause:
        Sizing for application

        Resolution
        The entire width of the unit is a = 15.75 in (400 mm), the entire height of unit is b = 26.38 in (670 mm), the entire depth of the unit is c = 11.81 in (300 mm), and the weight is 113.3 lb (51.4 kg).

         

        How to change the display settings of energy units from MWh to kWh in ME Meter.

        Depending on the ME meter version, meter will automatically select the appropriate units and therefore it is not possible to modify the energy units. From 40/5 to 150/5 CT ratio, the energy unit display is KWh and from 200/5 to 6000/5 CT ratio, the energy unit display is MWh.

        CT Setting:
        To change the CT settings hold down the button on the Front Face of the ME Meter for more than 5 sec when on the CT Rating display. After approximately 5 sec the display will start blinking, now enter the CT setting. Once again hold the button till the display stop flashing, to ensure that the entry is saved.

        How the user can control the ‘Start-up” voltage drop of the motor feeder in My Ecodial L.

        My Ecodial L 3.4 enables the user to change or set the limit for “Start-up” voltage drop of the motor feeder circuit.
        But the maximum value allowed by the Ecodial – to set the feeder startup voltage drop is 15 %. (The same is also supported by the UTE C 15-105 (French) standard.)

        (Below figure is showing the circuit characteristics; and the place to set the limit for the start-up voltage drop).


        Netbotz Advanced view errors during Installation: “The uninstallation could not complete due to an error.”

        Issue:
        Netbotz Advanced view errors during Installation: “The uninstallation could not complete due to an error.”

        Product Line:
        NetBotz

        Environment:
        NetBotz version 2 Advanced View

        Cause:
        If you receive this error when upgrading Advanced View from a previous version, click OK in the error message box. The installation proceeds normally and appears to complete successfully, but some portions of the previous version of Advanced View are not successfully deleted.

        Resolution:
        To complete the uninstallation of the previous version of Advanced View:

        1. Delete any desktop icons from the previous version of Advanced View.
        2. Delete any Start menu entries for the previous versions of Advanced View
         

        "ISX Central's Internal Browser ""Home"" button doesn't work with 2.x NMC Firmware"

        Issue:

        ISX Central's Internal Browser ""Home"" button doesn't work with 2.x NMC Firmware

        Product Line:

        InfraStruxure Central / Struxureware Data Center Expert.

        Environment:

        InfraStruxure Central / Struxureware Data Center Expert
        Any version 2.x firmware on APC SNMP enabled devices.

        Cause:

        Any APC device running older 2.x firmware reacts differently due to coding differences.

        Resolution:

        There is no plan to update this feature at this time to work with the older devices.

        Is there a skirting mount double power outlet rated to 15A, 250V?

        Unfortunately not, we do not have skirting mount double power outlet rated to 250V 15A .

        In 15A , 250V, skirting mount, we have the following options:

        16/15 -  Single Power Outlet 250V 15A, Skirting Mount, Plate size 98 x 41mm at centre.
        For further information, please visit
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=16/15

        16/2MF1510 - Double Power Outlet 250V 15A and 10A combination, Skirting Mount, suits ducting (156.5 x 44mm).
        For further information, please visit
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=16/2MF1510

         

        How do i silence my 755PSMA2?

        To silence the 755PSMA you need to press and hold the buttton on the front of the smoke detector for 10-15 seconds not only will it silence the alarm but it will also reset it.
        Some of the key features are:
        • New look design with easy to use test/hush button
        • Easy installation and maintenance
        • Wired interconnect feature (up to 40 alarms)
        • Optional relay or wireless interconnect bases
        • Backwards compatible with 755PSMA and 755SMA mounting bases
        • Robust digital design

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=755PSMA2


        Why wont my 755PSMA2 smoke alarms interconnect?

        To test the interconnect between the smoke alarms you are required to hold the test button for 10-15 seconds. The Smoke alarm you are testing will then pause and you will be able to hear the other alarms start alarming until your finger is released from the test button.

        For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=755PSMA2
         

        How to perform MSET on a BPH motor using Lexium 17/15 Servo Drive?



        Issue:  Although the BPH motors that are used with the Lexium 17 and 15 range of Servo drives are factory MSET, occasionally there may be a need to MSET this in the field due to commutation error being reported. 


        Product Line: Lexium BPH


        Environment:


        Cause: Due to an incorrect offset value set in the drive, the drive may report a F25, commutation error.


        Resolution: This resolution discusses the MSET procedure for a BPH motor with a Lexium 17/15 series drive.

         
        Proper commutation and position feedback are required to interface a particular servo drive and motor combination. When using Schneider Electric BPH motors and Lexium drives, this setup (or “characterization”) process has been completed and verified for the user at the factory. Occasionally there may be a need to MSET the BPH motor and this is detailed in this procedure.
         
        Perform the following steps, as described, and in the order presented, to complete the MSET procedure. 
         
        1.    Disconnect the Motor from the Mechanical Load
        2.    Electrical Connections
        A.   Verify that the required electrical connections for drive power, logic power, motor power and resolver are as described in the Lexium drive user manual.
        B.   Apply 24VDC logic and AC input power to confirm proper drive startup sequence and self-checks.
         
         Follow this MSET procedure only if the drive firmware is ver 5.51 and above.
         
         Connect to the drive using Hyperterm…
         
        1. Type OPMODE followed by Enter – note down the Opmode (xx) the drive is set to.
         
        1. Type OPMODE 2 followed by Enter – switch to digital torque mode
             C.     Type 'EN' followed by Enter.

             D.     Type "Zero" followed by ENTER - Motor shaft will jump to nearest pole. MPHASE value is automatically set.
         
          
        1. Type SAVE
         
        1. Type OPMODE xx followed by enter ( where xx is the default value that was originally set for the application.)
         
             G.    Type COLDSTART (the drive will reboot)
        This completes the MSET procedure.

        New SeaLevel PIO-48 does not work with NetBotz appliances.

        Issue:

        Sealevel® SeaLINK PIO-48 Part number 8203-FX is not compatible with NetBotz Appliances.

        Product Line:

        NetBotz

        Environment:

        Third party device connectivity.

        Cause:

        Due to an unavoidable change to the SeaIO software driver, the Sealevel® SeaLINK PIO-48 Digital I/O Adapter, Part number 8203-FX, is not compatible with NetBotz appliances. For more information, go to https://www.sealevel.com/support/.

        Resolution:

        To increase the number of I/O sensors that can be connected to your NetBotz appliance, the following USB digital I/O devices are supported: Sealevel SeaLINK PIO-48 - Part number 8203 only - (adds 48 digital I/O connections) Sealevel SeaI/O 462U (adds 96 digital I/O connections) Sealevel SeaI/O 463U (adds 96 digital I/O connections) Sealevel SeaI/O 450U (adds 16 digital I/O connections)

        Can split doors be installed on the front of a NetShelter SX, VX or SV cabinet?

        Issue: 
        It can not be assumed that the rear split doors will install onto the front of the cabinet. Confirmation is needed.  

        Product Line: 
        NetShelter SX, NetShelter VX, NetShelter SV
         
        Environment:
        All versions and serial ranges.
         
        Cause: 
        A customer may want to install split doors onto the front of a NetShelter SX cabinet.
         
        Resolution :

        Rear split doors can be installed onto the front of a NetShelter SX, VX and SV cabinets. 
        A replacement split door kit can be purchased or the existing split rear doors can be swapped to the front of the cabinet.
        The replacement door kit includes all of the necessary hardware, including hinges.
        The NetShelter one-piece front door may also be installed onto the rear of the cabinet. 
         

        What is Dynamic Host Configuration Protocol (DHCP)?

        Dynamic Host Configuration Protocol ( DHCP) is an open industry standard that is designed to reduce the complexity of TCP/IP network administration. This runs as a service on a server on your network. The server can be a Unix, Linux, or Windows platform based server. At a minimum, DHCP will provide client systems with an IP address, subnet mask, and default gateway. It can also provide the Domain Name System (DNS) and Netbios name (WINS) servers, and the DNS Domain name.
        A client system can be a computer, or any device that allows the dynamic assigning of IP addresses., such as a 170ENT1100x, or a 140NOE771xx. For more information on DHCP refer to the Internet Engineering Task Force (IETF) Requests for Comments (RFCs) 1533, 1534, 1541, and 1542.


        Legacy KB System (APS) Data: RESL120523 V1.0, Originally authored by on , Last Edited by on
        Related ranges: ConneXium - Ethernet

        Where do PDUs mount in the NetShelter CX?

        Issue:
        The NetShelter CX includes a 14-15 outlet PDU. Some customers may want to replace it with a larger PDU.

        Product Line:
        NetShelter CX

        Environment:
        All versions and serial ranges.

        Cause:
        Customers wanting to install a larger PDU into a NetShelter CX need to know where, and how, to install it.

        Resolution:
        In the NetShelter CX, APC 0U PDUs mount toollessly to the rear cable tray via toolless mounting pegs. There are two cable trays in each cabinet, one on each side. The document attached below shows a PDU mounted in the right rear cable tray.
        For a list of APC 0U PDUs that are compatible with all NetShelter cabinets please see Knowledge Base document FA158651.
         

        Is StruxureWare DCE or NetBotz susceptible to the WannaCry vulnerability?

        Issue:

        Is StruxureWare DCE or NetBotz suceptable to the WannaCry vulnerability?

        Product Line:

        StruxureWare Data Center Expert (DCE)
        AP9465, AP9470, AP9475, AP94VMTRL

        StruxureWare Data Center Operation (DCO)

        NetBotz
        NBWL0500, NBWL0420, NBWL0320, NBWL0355, NBWL0455, NBRK0450, NBRK0550, NBRK0570

        APC Network Management Cards (NMC)
        ·                          Network Management Card 1 - AP9617, AP9618, AP9619
        Devices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP78XX, AP79XX), Rack Automatic Transfer Switches (AP77XX, Environmental Monitoring Units (AP9320, AP9340, Netbotz 200, NetBotz 250)
        ·                          Network Management Card 2 - AP9630/AP9630CH, AP9631/AP9631CH, AP9635/35CH
        Devices with an embedded Network Management Card 2 include (but are not limited to): 2G Metered/Switched Rack PDUs (AP84XX, AP86XX, AP88XX, AP89XX), Certain Audio/Video Network Management Enabled products.



        Environment:

        Any version DCO, DCE, NetBotz appliance, or NMC

        Cause:

        CVE-2017-0144, also known as WannaCry, is a high level vulnerability that many customers have contacted Schneider Electric about to find out if StruxureWare DCE or NetBotz are vulnerable.

        Resolution:

        WannaCry allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability."

        As per the link below, this effects:
        Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607
        https://www.cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-0144

        Neither DCE, DCO, NetBotz, or the APC NMC run any version of Windows operating system and as such are not vulnerable to this attack.
        More information on these platforms can be found on https://DCIMsupport.apc.com

        Link150 Password Reset

        Issue
        It is not possible to generate the backdoor password of Link150. We have to perform only the factory reset so Link150 will return to the default user name and password.
        Product Line
        Link150

        Cause
        Forgetting the web page password for the Link150

        Resolution
        Module State Indication LED shall flash, GREEN for first 10 seconds, and then RED for 10-15 seconds. 
         
        Actions Effects
        Press and hold the 'reset pin' 1 - 5 seconds     LED: Flashing GREEN
          10 - 15 seconds     LED: Flashing RED: All user-configurable information is reset to factory defaults


        Release the pin when the Module State LED starts flashing RED (i,e 10 - 15 seconds)    Device reboots.
        Factory settings will be applied. The default password can be found at FA299649

        NOTE: 
        •    If the 'reset pin' is released, after 5 seconds and before 10 seconds, no action will be performed, LED will be flashing GREEN, till the 'reset pin' is released.
        •    If the 'reset pin' is released after 15 seconds, no action will be performed, LED will be turned to GREEN. 

        What is the replacement AC coil for CAD32 and CAD50 relay?

        Issue:
        Are replacement  AC coil available for CAD32 and CAD50 relay?

        Product Line:
        Tesys Relays

        Environment:
        All Products

        Cause:
        Product selection

        Resolution:
        Volt = coil part number
        12 = LXD1J7
        21 = LXD1Z7
        24 = LXD1B7
        32 = LXD1C7
        36 = LXD1CC7
        42 = LXD1D7
        48 = LXD1E7
        60 = LXD1EE7
        100 = LXD1K7
        110 = LXD1F7
        115 = LXD1FE7
        120 = LXD1G7
        127 = LXD1FC7
        200 = LXD1L7
        208 = LXD1LL7
        220/230 = LXD1M7
        230 595 21 LXD1P7
        230/240 = LXD1U7
        277 781 30 LXD1W7
        380/400 = LXD1Q7
        400 = LXD1V7
        415 = LXD1N7
        440 = LXD1R7
        480 = LXD1T7
        600 = LXD1X7
        690 = LXD1Y7

         

        What is the part number for a single pole, din rail mount, analogue timer?

        The part number for a single pole, din rail mount, analog timer is a 4TC for the Clipsal option.
        Schneider also offers the following products:

        ION over Modbus communications for PM8000 and ION7400 series meters

        Issue
        New features and improvements were made on firmware version v1.4.1 for the PM8000 and ION7400 meters. This attached document (TechnicalBulletin_ION-Modbus_v1.3) addresses issues related to replacing legacy products on a Modbus serial (RS-485) bus connected to PME systems.

        ION over Modbus is a communications method that allows an ION master such as EcoStruxure™ Power Monitoring Expert or PowerLogic™ ION Setup software full access to all the ION modules inside the ION meter, while communicating using Modbus RTU protocol on the serial daisy chain.

        The primary use of ION over Modbus is specifically for retrofit applications, where a Modbus meter such as the PowerLogic PM800 series meter is being replaced by an ION meter such as the PowerLogic PM8000 series meter on the RS-485 serial bus.

        Product Line
        PM8000
        ION7400

        Cause 
        ION masters such as Power Monitoring Expert (PME) and ION Setup use ION protocol to communicate with an ION meter to access and manipulate the ION modules in the meter.  However, if the ION meter is added to a Modbus serial daisy chain, the ION meter must be configured as a Modbus device (i.e., protocol set to Modbus RTU) to allow Modbus masters access to the mapped Modbus registers in the ION meter.
         
        PME and ION Setup use Modbus protocol to communicate with a Modbus gateway and the serial daisy-chained meters.  Historically, an ION meter that has been added as a Modbus RTU device in the Modbus serial daisy chain cannot be easily configured, i.e., PME or ION Setup cannot access the ION modules in the meter because the communications protocol is set to Modbus RTU, not ION. 

        Resolution
        All ION meters support the Modbus RTU protocol. Newer ION meter firmware adds ION over Modbus functionality. This enables an ION master such as Power Monitoring Expert or ION Setup to access all configuration and historical data in the meter while it is connected to a serial communications bus and configured as a Modbus RTU device

        Updates are available for Power Monitoring Expert and ION Setup to support ION over Modbus for communication networks utilizing an Ethernet to serial gateway device to connect to the serial daisy chain.



        Power Monitoring Expert and ION Setup currently do not support ION over Modbus communications for:
        • Direct Ethernet or direct serial communications connections.
        • Serial communications sites that use serial-to-serial communications converters such as an RS 232 to RS 485 converter or USB to RS 485 adapter.
        • Modem sites (telephone, radio or fiber optic).
        Serial communications considerations
        ION meters can generate larger volumes of historical data, events or waveforms, which might cause communications performance issues.  It is recommended not to exceed 10-15 devices wired on the same RS-485 daisy chain.


        Prerequisites
        To use ION over Modbus, both your ION meter and ION software must meet the minimum requirements:
        ION meter
        • PM8000 firmware v1.4.1 or later
        • ION7400 firmware v1.4.1 or later
        ION software
        • Power Monitoring Expert 8.2 CU1  (Cumulative Update #1) or later. This update is available for download from this Box link.
        • The latest version of ION Setup (available from Box at Schneider electric)

        For more information on ION over Modbus Communication, review the attached Technical Bulletin.