bracket front mnt 2g horiz

Mounting Accessories Metal Bracket, 2 Gang, Front Stud Mount Horizontal

Catalogue Number: 155H2
bracket front mnt 2g horiz
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
bracket
Accessory / separate part category
mounting accessory
Shape
rectangular
Material
metal
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Can the 155H2 be used with the 2025H2 series ?

No, the 155H2 mounting bracket can not be used with the 2025H2 as the mounting holes do not line up. You can use a wall clip part number 2154/4.

For further information please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures

 

What is the acti 9 equivelant of the 15512

The part code is A9C30211

What is the plaster bracket to suit the P2025?

The part name is 155P2

Will 25/2V double outlet, large size, vertical fit on 155P2 plaster bracket?

Yes, 25/2V will fit on 155P2. 25/2V is  Large Size Format 115 x 115mm, Double Power Outlet rated to 250V 10A.
For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=25/2V
User-added image

155P2 is a large plaster mounting bracket with 84mm mounting centre. For further information please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=155P2
User-added image
 

What would be the Wall plate (plaster) to suit Prestige large switches?

The wall plate would be the 155P2.

Please go to the website via the following link www.clipsal.com/Trade/Products/ProductDetail  and check under the Documentation Tab for more information.

What are the part names for the mounting equipment for the Saturn 4025H2?

Wall clip - 2154H2
Wall Bracket - 2155PHRM2
Wall Box - 2157H2

What mounting options can be used with 4025H2 or Z4025H2 ?

Use a 2154H2 ( wall clip) , 2155PHRM2 ( plaster mount bracket ) or 2157H2 ( Wall box) recessed 8mm
for more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=4025h2

What is the replacement for Merlin Gerin 15322 ?

A9A15322

What is the separator for a 15092

 The separator part code is 27001

alternative for Merlin Gerin Code 15962 ?

 A9C20834

What bracket is used to suit the larger Prestige range.

The bracket would be the 156/2.
This is also available in a wall box version as a157/2.
Please see below documentation for more information.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=156/2

What is the wall box for a P2033/2VA-WE

 Part code 157/2

What is the Replacement Acti9 code for the Merlin Gerin 15322 din rail mounted buzzer?

Looking for a 80A 3pole din rail mount mains switch

The mains switch is 15092

What is the part code for a 1P 32A relay

 The part code is 15515

What is the wallbox to suit the 4025H2?

The part name is as follows: 2157H2

Can you use two flush boxes behind a Saturn quad socket?

Yes you can it has 2x84mm mounting centers. Or you can use the 2154H2 mounting bracket or the 2157H2 Metal wall box.

What are the mounting centers for the 3155H4 mounting bracket?

The mounting centers of the 3155H4 mounting bracket is 179.8mm.

What is the part code for a pulse relay 16Amp 2P 240V ac coil voltage

Use a 15520

What is the flush box to suit the Clipsal 4025H2-OM ?

Use a Clipsal 2157H2

What is the alternative safety transformer part code for the Merlin Gerin 15222?

Part number 15222 is no longer available the alternative is the A9A15222.
Please use link for Data sheet:
https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9A15222
 

What is the double horizontal wall box for Saturn series

Use a 2157H2
or a 2154H2 mounting bracket
 

L1JCN - What is the code for the flush box to suit 31/2VX-WE

157/2 wall box 2gang

What is part number for bracket to suit BSL31VA?

The part number for bracket to suit is 155P.

What is the part code for a 240 to 24V 100VA transformer

The largest transformer that we have is 63VA - The part code is 15222

what is the Acti 9 code for Merlin Gerin 15515?

A9C30831 is the Acti9 code for the 1P 1NO 32A 230v AC impulse relay.

What is the flush box to suit the Clipsal 4025H2-OM ?

Use a Clipsal 2157H2

What are the dimensions of the INS400 single handle transfer switch 31150?

205mm x 395mm x 155mm (H x W x D) excluding the handle.
Overall depth with standard handle is 213mm.
See attached.

What wall clip is used for Prestige large format plates?

The 154/2 is the clip to suit any Prestige large format plate 115mm x 115mm

Part number for a C clip to suit prestige range?

The part name is 154/2

What are the outside dimensions of the FPSS121-CAT6?

The dimensions are 121mm (W) X 83mm (H) X 155mm (D).

What is the mounting bracket to suit part number 3015/4?

The part number is 3155H4 at this stage anticipated release is December 2016.

What is the mounting bracket to suit Prestige large format plates?

Part number 156/2 can be used on all Prestige large format plates.

What is the difference between the Surge Arresters reference 15597 and 16447

The difference between the Surge Arrester references 15597 and 16447 is as follows:

1.) 15597 is a PF20 3Pole Fixed type Type 2 LV Surge Arrester.
2.) 16447 is a PRD20 3Pole Withdrawable type Type 2 LV Surge Arrester. 

Both are suitable to be used in low risk level and for use in TNC Earthing systems.

The difference is that 15597 at its end of life needs to be replaced as it is Fixed type, while 16447 at its end of life can be reused by simply replacing the cartridge as it is Withdrawable type, and the other major advantage is that the wiring does not get disturbed.

Will the 9001KA contact blocks work at 24VDC?

Issue:
Will the 9001KA contact blocks work at 24VDC?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Cause:
Product Features

Resolution:
9001 KA1-KA6, KA21-25, KA31-35, KA1G-KA6 contact blocks will work on 24VDC providing the do not exceed 1.1amp make and break nor exceed 10 amps continuous current.


CTA-ID : 15554

What is the flush box to suit the P2025/2?

Standard 2 gang flush box will suit -  part number 157/2

What is the code for a 24 Hour Timer to fit into a 56 series E1 enclosure

PDL56TC24HB - Mechanical Synchronous, 1 channel, 15 min switching min 150hr Backup
PDL56TCU - Digital Quartz, 10yr Bat.Backup, 1 channel, 20 storage spaces

What is wall box to suit Saturn Zen part no Z4025H2

The 2157H2 is used on both standard Saturn & Saturn Zen

6610VT1 Wiggy Voltage Tester Leads

Issue:
What are the replacement leads for a 6610VT1 Wiggy voltage tester? 

Product Line:
Obsolete voltage testers formerly sold by Square D Company.

Environment:
Wiggy voltage testers

Resolution:
The 6610VT1 voltage test and all related accessories are now obsolete with no replacement. Consider another manufacturer of similar devices.  

Is there a bracket to mount sockets onto Actassi trucking?

You can direct mount onto the lid of the 80 or 155mm trunking or use the ISM15150

Other options are the Unistrut 2087016 and adaptors can also be found at cccutting.co.nz

What is the part number of the wall clip suitable for large format Prestige P2000 plates?

The part number for the wall clip suitable for large format Prestige P2000 plaes is 154/2.

What is the dimension of 90BD2 insulating shroud?

The dimension of 90BD2 insulating shroud is 105mm(length) 78mm(width) 65mm(depth). 90BD2 insulating shroud, large type format, deep type, meets double insulation requirements (suits 156/2 metal brackets).
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=90BD2
User-added image

How is it possible to determine if an Enercept Meter is the Basic or Enhanced model?

A System ID register located at addresses 30 (Integer) and 315 (Float) exists within the Enercept Meter. Reading that register will yield one of two values:
A value of 15022 will be returned from the Enhanced Enercept model.
A value of 15023 will be returned from the Basic Enercept model.

What are the baud rate options on the ATS48 modbus port?

Issue:
What is the baud rate for ATS48 modbus? 

Product Line:
ATS48 

Environment:
All 

Cause: 
Need to use 115.2 baud

Resolution:
ATS48 modbus is only available at 19200 or 9600.
Please note that the remote HMI only works with the 19200 baud rate.

Do you have an AMP meter to fit into the 56 Series enclosure?

There are two options available and they are both DIN rail mount which will fit into a 56CB4.

  1.  Part number: 15202 - This unit is a "direct connect" device and is rated up to 10A and it is 2 modules wide.
  2. Part number: 15209 - This unit uses C/T Clamps to measure the current and is rated from 0-5000A and it is 2 modules wide. (clamps not included)
For further information please visit https://www.schneider-electric.com.au/en/product-range/994-digital-amp---vlt--fre/

ATV58HC23N4 and ATV58HC28N4 Current Gain board part number?

Issue:
What is the Current Gain Board part number for an ATV58HC23N4 and ATV58HC28N4 ?

Product line: 
ATV58HC23N4  and ATV58HC28N4

Environment: :
ATV58,  All serial numbers

Resolution: 
The part number is  VX5A38C15.  Obsolete no replacement part.

Does Schneider Electric have any Altivar drives that do regeneration?

Issue:
Does Schneider Electric have any Altivar drives that do regeneration?

Product Line:
Altivar Process 980 Regeneration Drive

Resolution:
The Active Front End (AFE), Altivar Process 980 Drive system is a packaged, high-performance solution for regenerative applications. This regenerative drive is highly efficient in four-quadrant technology for speed control in both directions. The horsepower range is 150hp - 900hp.

Is there a wall box to suit 3015/4 ICONIC quad outlet?

No unfortunately there is no wall box to suit 3015/4 ICONIC quad outlet.

The only mounting accessory available for the 3015/4 is a 3155H4 which is a stud bracket.

For further information on our product range please visit Trade - Clipsal by Schneider Electric



 

Problem: Cannot establish communications via USB with the SMT or SMX UPS after installing PowerChute Agent.

Issue: Cannot establish communications via USB with the SMT or SMX UPS after installing PowerChute Agent.

Product Line:
PowerChute Business Edition

Environment:
All supported OS

Cause:
USB cable not connected during software installation

Solution:

If you installed the PowerChute Agent without the USB communications cable connected to the UPS, then you cannot subsequently establish communications. You need to correctly connect the USB communications cable from the computer to the UPS and then re-install the Agent.

If the USB cable was connected during installation please review knowledge base document FA163608

PowerChute Personal Edition 3.X "has stopped working" on Windows Vista or Windows 7.

Issue:
PowerChute Personal Edition 3.X "has stopped working" on Windows Vista or Windows 7.

Product Line:
PowerChute Personal Edition version 3.X

Environment:
All supported Windows OS

Cause:
If you see "PowerChute has stopped working" on Windows Vista or Windows 7

 

the reason is missing Arial font/s on your system. To check to see if Arial.ttf and or Arialbd.ttf are missing look in C:\Windows\Fonts\Arial

Solution:

If they are missing you can load the Arial fonts - font family from you system CD, system back-up drive, or back-up CD. You may also download the fonts from Microsoft.com