Thorsman Eye Anchor M8, Set of 25

Thorsman Eye Anchor M8, Set of 25

Thorsman Eye Anchor M8, Set of 25

Item Number: 1511227

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Thorsman

Product or component type

eye anchor

Physical

Mounting support

  • ceiling
  • wall
  • floor
    • Provided equipment

    • nut
    • washer
      • Quantity per set

        set of 25

        Sale per indivisible quantity

        25

        EU RoHS Directive

        Pro-active compliance (Product out of EU RoHS legal scope)

        Environmental Disclosure

        ENVPEP1401003EN

        Others

        Thread type

        M8

        Package 1 Weight

        47 g

        Package 1 Height

        24 mm

        Package 1 width

        19 mm

        Package 1 Length

        90 mm
        Show all specifications

        Frequently Asked Questions

        hide show

        What is Advantys STB?

        Advantys STB (smart terminal block) is an open, modular distributed I/O system designed for the machine industry, with a migration path to the process industry.  Modular I/O, power distribution modules (PDMs) and a network interface module (NIM) reside in a structure called an island.  The island functions as a node on a fieldbus control network and is managed by an upstream fieldbus master controller.

        Can the DBF30 be a three phase board

        Yes - all boards can be wired as three phase by using three phase comb busbar

        What is the MTBF for HMIBM series?

        Issue:
        Unable to find any documentation regarding the MTBF for the HMIBM series.

        Product Line:
        Magelis HMIBM series iPC

        Resolution:
        The MTBF values for the HMIBM series are as follows:

        HMIBMU -> MTBF = 171,527 hours @ 30 Degrees C
        HMIBMP -> MTBF = 140,889 hours @ 30 Degrees C

         

        Will the ZB2BZ21 push-on/push-off operator work with illuminated pushbuttons that have a light module?

        Issue:
        Will the ZB2BZ21 push-on/push-off operator work with illuminated pushbuttons that have a light module?

        Product Line:
        Harmony Pushbuttons

        Environment:
        Obsolete Products

        Cause:
        Product Features

        Resolution:
        Yes you can use with illuminated pushbuttons.


        CTA-ID : 2022122

        Can the ATV31...A model be setup to use the integral speed pot dial for reference adjustment, but use the LI logic input for a run forward command?

        Issue:   Can the ATV31...A model be setup to use the integral speed pot dial for reference adjustment, but use the LI logic input for a run forward command?
         
        Product Line:   ATV31
         
        Environment:  ATV31**A models
         
        Cause:   N/A
         
        Resolution:   Yes.  In the IO menu, set parameter tCC to 2C.  This assigns LI1 as run forward command.  In the CtL menu, set parameter Fr1 to AIP.

         

        Why does my Rack ATS (AP77XX) lose SNMPv1 communication with my StruXureWare device or ISX Manager?



        Issue

        My Rack ATS (AP77XX) is losing SNMPv1 communication with my StruXureWare device, ISX Manager, or other SNMP NMS periodically.


        Product Line
         
        • Only the following Rack Automatic Transfer Switch (ATS) models:
          • AP7752
          • AP7753
          • AP7721
          • AP7723
          • AP7724
          • AP7730
          • AP7732

        Environment
         
        • All serial numbers
        • Rack ATS app g2ats v3.5.7 and below
        • Rack ATS monitored by the SNMPv1 protocol


        Cause

        An issue has been previously indentified with the aforementioned Next Generation Rack ATS product firmware that causes the device to lose SNMPv1 communication with StruXureWare, ISX Manager, or other SNMP monitoring programs. This issue occurs after an undefined amount of uptime but limiting access control to specific devices seems to help increase the uptime to about 30-45 days for the integrated Network Management Card.


        Resolution


        This has been addressed in Rack ATS Firmware g2ats v3.7.0 and higher. If you are unable to update to v3.7.0 or higher from https://www.apc.com/tools/download/index.cfm, a warmstart of the Network Management Card Interface is required to re-establish communication. This can be accomplished by pushing the "Reset" button on the front of the ATS or issuing the Reboot Management Interface from the Network Management Card UI (web, telnet/SSH, or local console). This action does not disrupt power output of the ATS and only reboots the Management Interface.