box junction adaptor plate

General Accessories Mounting Brackets, Metal Adaptor Plate To Suit Junction Box

Catalogue Number: 150
box junction adaptor plate
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
adaptor plate
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

  • Corporate Marketing

Frequently Asked Questions

hide show

Which networks are supported on the Modicon Momentum by Communication adapters

The following networks are supported by Modicon Momentum Communication adapters

Communication adapters for Ethernet TCP/IP
170 ENT 110 02 Transparent Ready Class A10
170 ENT 110 01 Transparent Ready Class B20
 
INTERBUS SUPI 3
170 INT 110 03 Twisted Pair
170 INT 120 00 Fibre optic
 
INTERBUS I/O bus SUPI 2
170 INT 110 00 Twisted Pair
 
Profi bus DP
170 DNT 110 00
DeviceNet
170 LNT 710 00
 
Modbus Plus
170 PNT 110 20
170 PNT 160 20
170 NEF 110 21
170 NEF 160 21
 
Fipio
170 FNT 110 00
170 FNT 110 01

what wattage is PDL26 lamp holder ?


150 Watt

What dimmer can handle 4 x 150 watt high bays?

The C2031E4RUD-WE is rated at 800 watt so it will be able to handle 4 x 150 watt high bays.

How is current unbalance calculated on the DM6200?

Issue
The Current Unbalance formula is not detailed in the DM6200 User Manual.

Product Line
DM6200

Environment
Reading verification

Resolution
The current unbalance is calculated using the following equation:

I unbalance = (Max phase current - Min phase current) / Avg 3 phase current * 100

For example:

Ia = 100 A
Ib = 120 A
Ic = 150 A

Therefore, Max phase current = 150 A, Min phase current = 100 A, and Avg 3 phase current = (100 + 120 + 105) / 3 = 108.3 A.

I unbalance = (150 - 100) / 108.3 * 100 = 46.2 % unbalance

Where can I find Application Note 150 which details scalability of the PX20 all in one UPS

Issue:
Where can I find Application Note 150 which details scalability of the PX20 all in one UPS
 
 
Product line:
ISX20K20F PX1 20K AIO
 
 
Environment:
ALL
 
 
Resolution:
Provide information on application note 150 which details scalability of the PX20K all in one UPS – ISX20K20F
 
https://www.apc.com/salestools/AWAR-7KEP2T/AWAR-7KEP2T_R0_EN.pdf
 
 

What is the part number for 50 X 150 TALplus / Moduline duct?

The part number for 50 X 150 duct is PL50150D*

 

*=Colour code

For further information see page 433, 434 Of the Trade Product Edition 93

or page 474 of Edition 92

or visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/CMS0005.pdf

How do you set up the process drive to give you 150% starting current?

Issue: 
What are the limitations of heavy duty and normal duty in regards to starting current 110% and 150%?

Product Line:
Altivar ATV630 Process drive.

Environment:
All

Resolution:
The normal duty or heavy duty could be configured via a parameter drive DRT.  Normal duty will give you 110% starting current and heavy duty will give you 150% starting current.


 

Are there End Plugs available for the 150 x 75mm (900/150/75) Maxi Duct Trunking?

We do not currenlty stock any fittings for the 150 x 75mm Maxi Duct - This includes End Plugs, Internal, External and Flat Elbows etc...

Is MPPT60 150 a transformer or transformerless charger?

The MPPT60 150 is transformerless based charge controller. It is compatible with any brand of PV Module and Integrated PV ground fault protection for negative grounded arrays.

What is the part number for clip on Gray lid , 150 mm, moduline?

The part number will be PL150CLO.
 

Does Clipsal have a 150 kA surge arrestor?

No, the biggest we have is 40 kA - 940RMT/1.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=940RMT/1


What is the difference between a Transformer's "temperature rise" and its "insulation class"?

Issue:
Explanation of the difference between temperature rise and insulation class specifications.

Product Line:
LV Transformers

Environment:
Applies to Low Voltage Transformers by SquareD/Schneider Electric

Cause:
Transformer Temperature Rise and Insulation Class are two different technical attributes

Resolution:

This question has come up because NEC 450-21(b) requires Transformers larger than 112.5 kVA to be installed in fire resistant construction unless the insulation class is 155 or higher.

The insulation system of a Transformer is rated in degrees Celsius at its maximum temperature rating (the Class number = the degree C of the insulation system; example, a Class 220 insulation system is rated for 220°C) Transformers have either a Class 220 (former designation "H") Class 180 (former designation "F",) Class 150 (former designation "B") or Class 105 (former designation "A") Some smaller manufacturers may also use a Class 200 (former designation "R").

The temperature rise of a Transformer is the average temperature rise that will occur in the coils during normal full load.

The insulation system <> standard temperature rise relationships are:
Class 220 <> 150 degree Celsius rise
Class 180 <> 115 degree Celsius rise
Class 150 <> 80 degree Celsius rise
Class 105 <> 50 degree Celsius rise

A Transformer with a Class 220 insulation system can be designed for a maximum temperature rise that is lower than the standard 150 degree Celsius. It can be designed for either 115 or 80 degree Celsius rise. As well, a Class 180 insulation system Transformer can be designed with 80 degree Celsius rise. Class 150 and 105 transformers are not typically designed for other than their standard temperature rise.

Since all Square D low voltage dry type Transformers larger than 112.5kVA are built with a 220 degree Celsius insulation system, exception #2 under NEC 450-21(b) applies.

Do you have a 4 pole normally closed 159 Series contactor?

Unfortunately the 4 pole normally closed 159 Series contactor was a part of the Square D brand and has been discontinued.

Looking for a Himel enclosure - powder coated dimensions 400 x 300 x 150 - Is this available?

The NSYCRN43150P but you would need to take it to get powder coated yourself

Is there an Internal Elbow for truning size 150 x 50mm Maxi Duct Drunking?



No, largest internal elbow available is 900/100/100EI

What is the replacement for ACW-1 pressure switch?

The replacement for ACW-1 pressure switch is 9012GAW5
 9012GAW5 pressure switch 9012G - adjustable scale - 2 thresholds - 3.0 to 150 psig
9012GAW5
pressure switch 9012G - adjustable scale - 2 thresholds - 3.0 to 150 psig

For more information see;https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=9012GAW5

Video: How to upgrade the Link 150 firmware?

Issue:
How to upgrade the Link 150 firmware?

Product Line:
Link 150 (EGX150)

Environment:
Firmware upgrade

Resolution:


 
  1. Download the latest Link 150 firmware zip file attached below. 
    It can also be downloaded from this link
  2. Unzip the folder and store it in your local PC.
  3. Open the unzipped folder.
  4. Right-click the FirmwareUpgrade.bat, and then click Edit.
  5. Set the IP address, FTP user name, and password of the module being upgraded in the FirmwareUpgrade.bat file.
  6. Save and exit the FirmwareUpgrade.bat.
  7. Double-click the FirwareUpgrade.bat file, this starts the upgrade process. 
  8. Wait until the FirwareUpgrade.bat closes itself.
  9. After successful firmware upgrades, the Link 150 will take 40 seconds to restart. 
Note:
  • Default IP address = 169.254.YY.ZZ where YY and ZZ are the last two bits of the Link 150 MAC address. 
  • Default FTP user name = Administrator
  • Default FTP password = Gateway

What is the lug torque specification for a Powerpact J frame circuit breaker?

Product Line:
Circuit Breakers
PowerPact J

Environment:
Electrical Distribution Equipment

Resolution:
The standard al/cu lugs are rated at 225lb-in and require a 5/16 in hex bit torque wrench. See below for lug information.
The AL175JD ( 150 - 175A) is 225lb - in.
The AL250JD ( 200 - 250A) is 225lb - in.
The CU250JD (150 - 250A) is 250lb - in

See instruction bulletin, 48940-221-02

Are Momentum Ethernet modules full or half duplex?

The M1E Momentum processors are 10 meg half duplex. The 170 ENT 110 01 is 10/100 meg full/half duplex. The 170 ENT 110 00 is 10 meg half duplex..


What is the standard key used in a 9001KX,9001KR, 9001KS and 9001SKS selector switch?

Issue:
Replacement standard key for the 9001 oeprators.

Product Line:
Harmony Pushbuttons

Environment:
All Products

Resolution:
The standard key is the E10 key which is catalog number 2941101100.
 

What is the 154 that suits the Slimline range?

The 154 to suit the Slimline range is the 154RM.

Link 150 Device List option missing with ION protocol enabled

Issue
After switching the Link 150 (EGX150) to ION protocol support, the Device List is not shown anymore.

Product Line
EGX150

Environment
Gateway Protocol Support

Resolution

When the ION protocol is enabled, the following webpages are not needed which makes the options hidden:

Diagnostics → Device Health Check → Read Device Registers
Configuration & Settings → Network Configuration → Advanced Ethernet Settings
Configuration & Settings → Network Configuration → MBTCP/IP Filtering
Configuration & Settings → Device Configuration → Device List


 

Will changing the Display Hold slow down the scroll speed in my MPPT 60 150?

Issue
The customer would like to change the amount time the MPPT60 holds on a screen before switching to the next screen.

Product Line
MPPT 60 150

Environment
Using the display of the MPPT 60 150 to read information

Cause
The amount of time the MPPT holds on screen is too short

Resolution
The scroll time is set to 4 seconds.  Unfortunately, it is not configurable.  The Display Hold is not related to the scroll time.  Instead, the Display Hold is the amount of time needed without input for the MPPT 60 display to return to the home screen.

What is the wind resistance rating for a Flite 110 and Flite 116?

93 mph (150 kmh)

What is the depth of a Clipsal T150F main switch?

The depth is 81mm including the toggle.
It is 140mm (H) x 94mm (W)
The T100 and T150 (front or back wired) range are all the same body size.

Is the extra switch in the 15X removable?

Yes, the extra switch in the 15X is removable. Any 230v rated 30 series mec will fit in it's place.

 

What is the resistance to vibration for the ATV31?

Issue:
What is the resistance to vibration for the ATV31?

Product Line:
ATV31

Environment:
All

Cause:
Specifications

Resolution:
Conforming to IEC/EN 60068-2-6: 1.5 mm peak to peak from 3 to 13 hz, 1 gn from 13 to 150 hz.

Are the Altivar 650 and Altivar 950 Process Drives available?

Issue:
How do I order an Altivar 650 (ATV650) or Altivar 950 (ATV950) drive?

Product Line:
Altivar Process Drive (ATV650, ATV950)

Environment:
All serial numbers for Altivar 650 and 950 Process Drive 

Cause:
N/A

Resolution:
Altivar 650
This drive is now available to order.  

In the past ATV630........ EU was the part number used in place of the ATV650.....EU drives.    The only difference is the ATV630....... EU has a Black color disconnect and the ATV650...... EU has a Red color disconnect. 

Altivar 950
These drives are not available for ordering yet.
To order a Nema 12 drive:
 - Order an Altivar 960 Enclosed drive using Product Selector with Nema 12 option. (For End Users/Customers please your contact local distributor for assistance)
 

LC1D1506 What are the dimensions? Weight?

Height 158 mm
Width 120 mm
Depth 136 mm
Product weight 2.5 kg

Do you have a 15S in biege?

No, the 15S only comes in White Electric and Red.

Some of the key features are:
  • 1 pole
  • Standard size
  • Safety shutter
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=15Shttps://www.clipsal.com/Trade/Products/ProductDetail?catno=15S

Netbotz and FTP Return Codes

Issue:

Netbotz and FTP Return Codes

Product Line:

NetBotz

Environment:

NetBotz ftp codes

Cause:

When configuring the FTP Alert Action on a Netbotz device, the FTP server may return error codes which may viewed in the Appliance Log. The return codes may be used to further troubleshoot the problem.

Resolution:

The return codes for FTP servers are:

110 Restart marker reply. In this case, the text is exact and not left to the particular implementation; it must read: MARK yyyy = mmmm where yyyy is User-process data stream marker, and mmmm server's equivalent marker (note the spaces between markers and "=").

120 Service ready in nnn minutes.

125 Data connection already open; transfer starting.

150 File status okay; about to open data connection.

200 Command okay.

202 Command not implemented, superfluous at this site.

211 System status, or system help reply.

212 Directory status.

213 File status.

214 Help message.On how to use the server or the meaning of a particular non-standard command. This reply is useful only to the human user.

215 NAME system type. WhereNAME is an official system name from the list in the Assigned Numbers document.

220 Service ready for new user.

221 Service closing control connection.

225 Data connection open; no transfer in progress.

226 Closing data connection. Requested file action successful (for example, file transfer or file abort).

227 Entering Passive Mode (h1,h2,h3,h4,p1,p2).

230 User logged in, proceed. Logged out if appropriate.

250 Requested file action okay, completed.

257 ""PATHNAME"" created.

331 User name okay, need password. 332 Need account for login.

350 Requested file action pending further information

421 Service not available, closing control connection. This may be a reply to any command if the service knows it must shut down.

425 Can't open data connection.

426 Connection closed; transfer aborted.

450 Requested file action not taken.

451 Requested action aborted. Local error in processing.

452 Requested action not taken. Insufficient storage space in system.File unavailable (e.g., file busy)

500 Syntax error, command unrecognized. This may include errors such as command line too long.
501 Syntax error in parameters or arguments.

502 Command not implemented.

503 Bad sequence of commands.

504 Command not implemented for that parameter.

530 Not logged in.

532 Need account for storing files.

550 Requested action not taken. File unavailable (e.g., file not found, no access). (550 a:: no such directory means no diskette in a: drive.)

551 Requested action aborted. Page type unknown.

552 Requested file action aborted. Exceeded storage allocation (for current directory or dataset). 553 Requested action not taken. File name not allowed.
 

What is the socket to go with a BALS21241

PDL56SO532CEELEGY page 153 pocket book

Does Vijeo Designer Support the Rockwell Micrologix 850 controller?

No, Vijeo Designer does not support the Rockwell Micrologix 850 controller.

What is the replacement AC coil for CAD32 and CAD50 relay?

Issue:
Are replacement  AC coil available for CAD32 and CAD50 relay?

Product Line:
Tesys Relays

Environment:
All Products

Cause:
Product selection

Resolution:
Volt = coil part number
12 = LXD1J7
21 = LXD1Z7
24 = LXD1B7
32 = LXD1C7
36 = LXD1CC7
42 = LXD1D7
48 = LXD1E7
60 = LXD1EE7
100 = LXD1K7
110 = LXD1F7
115 = LXD1FE7
120 = LXD1G7
127 = LXD1FC7
200 = LXD1L7
208 = LXD1LL7
220/230 = LXD1M7
230 595 21 LXD1P7
230/240 = LXD1U7
277 781 30 LXD1W7
380/400 = LXD1Q7
400 = LXD1V7
415 = LXD1N7
440 = LXD1R7
480 = LXD1T7
600 = LXD1X7
690 = LXD1Y7

 

What are the dimensions of the 535 power tower

 Dimensions 158 x 158 x 140mm high

Do Clipsal have a 150 mm, 22.5 degree conduit bend in EO.

No,  unfortunately our bends only come in 45 degrees and 90 degrees.
The part number for a 45 degree 150mm bend is a 247PH150-eo.
Please see following link and look under documentation tab for complete range and specifications.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=247PH150

What is the part code for a caravan lead with RCD 15m permanent connection

 The part code is PDL 953/15

Is there a PDL 953/15 that is longer than 15m

 No not available 
Please note this product is being phased out

What are the replacement interiors for the 9001BW Pendant control stations?

 Issue:
Needs the replacement contacts or interior for 9001BW pendant stations

Product line:
9001BW Pendant control

Environment:
all models

Cause:
Replacement parts

Resolution:

Note replace the * with the enclosure color Y = yellow, B = black R = red
9001BW92* - replacement interior is 9001BOC368
9001BW93* - replacement interior is 9001BOC368
9001BW94* - replacement interior is 9001BOC358
9001BW95* - replacement interior is 9001BOC359
9001BW96* - replacement interior is 9001BOC358
9001BW97* - replacement interior is 9001BOC359
9001BW98* - replacement interior is not available

9001BW90*U - replacement interior is 9001BOC366
9001BW91*U - replacement interior is 9001BOC359
9001BW94*U - replacement interior is 9001BOC358
9001BW100*U - replacement interior is 9001BOC367
9001BW102*U - replacement interior is 9001BOC367

 

I have an LC1D TeSys D-Line contactor. Which are the coil terminals?

Issue:
I have an LC1D TeSys D-Line contactor.  Which are the coil terminals?

Product Line:
D Line contactors.

Environment:
Products sold in the United States.

Cause:
Product features.

Resolution:
The coil terminals are the ones labelled A1 and A2.


CTA-ID : 2011973

what are the dimensions of the ATV312HU40N4?

Height 184 mm
Width 142 mm
Depth 152 mm

Is there a 154 C-clip that does thicker than 10mm plasterboard/ gyprock?

Yes the 154/1 does plasterboard/gyprock thickness's between 19-25mm.

What is the 240v Shunt trip MX to fit a iC120 circuit breaker?

The MX stunt trip 100 VAC to 415 VAC and 110 VDC to 130 VDC to fit the iC120 and the C120 circuit breakers is the A9N26946

see data sheet .....
https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9N26946
User-added image

What is the motor trip unit needed for a LV430403 frame, 150A

Use a LV430500

What was a Unitized EZ Stack meter center?

Issue:
Product Features

Product Line:
Unitized EZ Metering Equipment

Resolution:
The Unitized EZ Stack devices were self-contained meter centers, available with up to six disconnecting means. The 100 ampere devices accepted field installed Type QO or Q1 tenant breakers. The 125 ampere and 150 ampere devices were supplied with factory installed Type Q2 tenant breakers. This product line is obsolete. The current offering for this application would be MP METER-PAK.


 

What is the part number for 4 pole 70ka 1250 amp micrologic 2.0 circuit breaker?

The part number for 4 pole 70ka 1250 amp micrologic 2.0 circuit breaker is 33481.
Please follow link attached for more information
https://www.schneider-electric.com.au/en/?q=33481

How do I adjust display language and contrast on MGE COMET 2-line LCD display

Issue:
How to adjust display language and contrast on MGE COMET 2-line LCD display
 

Product line:
Comet 50 to 150 kva UPS
 

Environment:
72-160500-44, 72-160502-42, 72-160522-22: 50 kva
72-160800-44, 72-160802-42, 72-160822-22: 80 kva
72-160400-44, 72-160402-42, 72-160422-22: 150 kva
 
Cause:
How to adjust display language and contrast on MGE COMET 2-line LCD display

Resolution:
See Attached document
 

 

Whats are the dimensions of the T200, T200FA, T200F, T200X, T200L, T200S

 210 x 158 x 112mm (L x D x W) 

Whats the dimensions for a T300, T300L, T300S

 210 x 158 x 117mm (L x W x D)

What lugs come standard on the PowerPact H frame breaker?

Product Line:
Circuit Breakers

Environment:  
PowerPact H

Resolution:
The 15 A through 150 A breakers have the AL150HD lug that will accept wire sizes of #14 through 3/0 Al or Cu.  The lug kit comes with 3 lugs.  
Show More