Quantcast

Automatic Single Socket Outlet, 250VAC, 10A, Skirting Duct

White Electric | Automatic Single Socket Outlet, 250VAC, 10A, Skirting Duct

Automatic Single Socket Outlet, 250VAC, 10A, Skirting Duct

Item Number: 12M-WE

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Series 12M

Product or component type

socket-outlet

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Quantity per set

set of 1

Marking

without marking

Local signalling

without light indicator

Mounting support

skirt

Fixing mode

by screws

[In] rated current

10 A

[Ue] rated operational voltage

250 V AC

Depth

29 mm

Length

63 mm

Width

43 mm

Number of poles

1

Standards

  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • REACh Regulation

      Free of Substances of Very High Concern above the threshold

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120506EN

      Others

      Cover type

      complete housing

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      68 g

      Package 1 Height

      30 mm

      Package 1 width

      43 mm

      Package 1 Length

      60 mm

      Unit Type of Package 2

      BB1

      Number of Units in Package 2

      10

      Package 2 Weight

      0.78 kg

      Package 2 Height

      76 mm

      Package 2 width

      102 mm

      Package 2 Length

      202 mm

      Unit Type of Package 3

      CAR

      Number of Units in Package 3

      200

      Package 3 Weight

      15.6 kg

      Package 3 Height

      305 mm

      Package 3 width

      296 mm

      Package 3 Length

      436 mm
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Specifications

      Frequently Asked Questions

      hide show

      What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

      Issue:
      Identifying maximum voltage of an LC1D contactor

      Product Line:
      TeSys D Contactors

      Environment:
      IEC contactors and starters used in North America

      Cause:
      n/a

      Resolution:
      IThe maximum voltage per UL and CSA is 600VAC. 
       

      What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

      Issue:
      Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

      Product Line:
      IEC Contactors and Starters

      Environment:
      Tesys D Contactors

      Resolution:
      For contactors with screw clamp terminals:
      stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
      stranded cable w/cable end: One or Two #18-10 AWG per terminal.
      solid cable: One or Two #18-8 AWG per terminal.

      What is the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38?

      Issue:
      LC1D09 - LC1D38 Coil tolerance

      Product Line:
      Contactors and Starters, IEC

      Environment:
      Tesys D Contactors

      Cause:
      Needs the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38.

      Resolution:
      AC single frequency coils: 50Hz and 60 Hz (-20% / +10%);
      AC dual frequency coils: 50Hz (-20% / +10%) ; 60Hz (-15% / +10%)
      DC standard coil for LC1D09 -D38 and LC1DT20 to DT40: (-30% / +25%)
      DC standard coil for LP1D12 and D25: (-20% / +10%)
      DC wide range coil for LP1D12 and D25 : (-30% to +25%)

      Can a molded case switch be reverse fed or backfed?

      Issue:
      Are the Powerpact and Legacy rated for feed in either direction?
       
      Product Line:
      Molded Case Switches
       
      Resolution:
      Yes, the molded case switches have been UL tested for reverse feed applications and are not marked line and load.

      What is the altitude derating for a TeSys D-Line contactor?

      Issue:​
      What is the altitude derating for a TeSys D-Line contactor?

      Product Line:
      Digest 177 Section 18 : Contactors and Starters, IEC

      Environment:
      North American Products

      Resolution:
      The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

      Voltage
      3500m x 0.90
      4000m x 0.80
      4500m x 0.70
      5000m x 0.60

      Current
      3500m x 0.92
      4000m x 0.90
      4500m x 0.88
      5000m x 0.86

      For example, an LC1D80 at 5000 meters:
      - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
      - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



       

      Is part number L5504D2U suitable for dimming LED?

      Yes. The L5504D2U is suitable for LED dimming.

      Key Features

      • 4 channel Leading Edge/Trailing Edge
      • 12M DIN modules wide
      • 4 channels of 2.5A rating
      • Suitable for low voltage electronic transformers, incandescent lamps and low voltage lamps with iron core transformersl
      • automatic load sensing
      • software selectable network burden and C-Bus system clock
      • inbuilt 200mA C-Bus power supply
      • C-Bus Learn Enabled
      • for use with Leading Edge or Trailing Edge compatible low voltage transformers
      • 215 mm x 85 mm x 65 mm
      for more information, please visit:https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504D2U

       
      Show More