sock swt mech auto side con

Automatic Single Socket Outlet, 250VAC, 10A, Skirting Duct

Catalogue Number: 12M
sock swt mech auto side con
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Grey 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 12M
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
Mounting support
skirt
Fixing mode
by screws
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Depth
29 mm
Length
63 mm
Width
43 mm
Number of poles
1
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • EU RoHS Directive
      Compliant
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Case Studies

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the sensing range of the FLS20SENLED?

      The sensor detection range of the FLS20SENLED is between 2m and 12m based on a mounting height of 2-3m.


      For further information please visit https://www.clipsal.com/Trade/search-results?q=FLS20SENLED


       

      What is the difference between L5508RVFP and L5508RVF?

      L5508RVFP and L5508RVF are C-Bus DIN Rail Mounted Relay Units, 250V AC 10A 8 Channel, 12M modules wide. The only difference between the two is L5508RVFP does not come with C-Bus Power Supply and L5508RVF is with 200mA C-Bus internal Power Supply.
      For further information, please visit:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5508RVFP
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5508RVF

      User-added image
      User-added image

      What are the limitations of the Modbus TCP IO Scanner of a TM251MESE?

      The limitation of the Modbus TCP IO Scanner of a TM251MESE are:
      - maximum 64 channels divided between maximum 64 slaves.
      Each channel has the following limitations:
      - for Read/Write Holding Registers the maximum length is 125 read words  and 121 write words
      - for Read Holding Registers the maximum length is 125 words
      - for Write Multiple Registers the maximum length is 123 words

      What hardware is required to add an M340 expanded backplane?

      Adding an expansion rack requires an Extension rack Module (BMXXBE1000), Extension rack Cable and Terminators.
      The BMXXBE2005 is an Extension rack kit that contains everything that you need including:

      • 2 BMXXBE1000 extension rack modules
      • one BMXXBC008K 0.8 meter extension cable
      • one TSXTLYEX set of 2 line terminators

      Other cable lengths available:
      BMXXBC015K - 1.5m extension rack cable.
      BMXXBC030K - 3m extension rack cable.
      BMXXBC050K - 5m extension rack cable
      BMXXBC120K - 12m extension rack cable







       

      Legacy KB System (APS) Data: RESL212579 V1.0, Originally authored by DaSo on 09/25/2013, Last Edited by DaSo on 09/25/2013
      Related ranges: Modicon M340

      How many socket outlets can be protected by a RCD or LIOM?

      To meet the requirements of the AS3003 wiring rules the number of sockets connected to a LPD device is associated with the area of installation.

      Cardiac Protected Areas
       
      • Connected to a LIOM 12x socket outlets (multiple patient locations).
      • Connected to a RCD 12x sockets (one patient location).
       
      Body Protected Areas
       
      • Connected to a LIOM (in accordance with AS3000 rules & multiple patient locations.
      • Connected to a RCD 12x sockets (multiple patient locations).

      Is the HMIGTU 12' display (HMIDT643) with built in WIFI compatible with both HMIG3U and HMIG5U?

      Issue: It is not possible to select the HMIDT643 with built in Wifi for a HMIG3U in Vijeo Designer or Vijeo XD.

      Product Line: HMIG3U, HMIG5U, HMIDT643

      Resolution:The new Magelis HMIDT643 12” Display with Wireless Lan can only be combined with the Open Box HMIG5U/HMIG5U2.

      What are the dimensions of LC1D40AB7 ?

      Height 122 mm
      Width 55 mm
      Depth 120 mm
      Product weight 1.4 kg

      What is the part code for a caravan lead with RCD 15m permanent connection

       The part code is PDL 953/15

      Is there a PDL 953/15 that is longer than 15m

       No not available 
      Please note this product is being phased out

      is the actpp6u24nss loaded

      yes as per page 126 clipsal book

      What is the range of a Clipsal 750WPR passive infrared sensor

      The beam scans a 18m radius out from the sensor and around 110 degrees in an arc

      What is the power dissipation for the XBTGT7340?

      The power dissipation of the XBTGT7340 is max. 35.3W (with 12W external load).

      Do you have a shielded CAT 5E 10m patchlead?

      No unfortunately this part is not available.

      What is the measurement for the mounting centres for the Clipsal 10M

      It is 84mm

      Is the VAMP 121 capable of tripping off of current and light?

      The VAMP 121 is only capable of tripping off of light.


      Legacy KB System (APS) Data: RESL210584 V1.0, Originally authored by DaFr on 02/07/2013, Last Edited by DaFr on 02/07/2013
      Related ranges: Others protection relays

      How many outputs does a VAMP 121 have?

      The VAMP 121 has one output contact.


      Legacy KB System (APS) Data: RESL210595 V1.0, Originally authored by DaFr on 02/07/2013, Last Edited by DaFr on 02/07/2013
      Related ranges: Others protection relays

      Is the dimensions for a Clipsal C2016/2-WE the same as C2016/2S

       No, the C2000 is 48mm x 160mm x 28mm  with 122 mounting centres

      do we do female/male bushes 12mm ?

      No - smallest is 16mm

      What size cable can be used with the Clipsal 413QC socket?

      1mm - 2.5mm
      See attached.

      What is the socket for 418SL or 439SL

      438L - Socket PVD 10A suit 1mm ord.duty flex, rnd Earth socket.

      What is the part code for a power supply with a 12V DC output?

      ABL8MEM12020 is 12V DC @ 2A

      What is the part number for a CAT6A patch panel, unloaded


      ACTPPAS24NS 
       
      page 126 of the 2014 Clipsal Pocket book.

      Are the new 6U, 9U and 12U NetShelter cabinets hinged in the rear like the AR100 & AR100HD?

      Issue:
      Customers inquire if the newer 6U, 9U and 12U wall mount cabinets are hinged in the rear.

      Product Line:
      NetShelter WX

      Environment:
      All versions and serial ranges.

      Cause:
      The 13U NetShelter WX cabinets are hinged in the rear.

      Resolution:
      The new 6U, 9U and 12U NetShelter WX cabinets (AR106, AR109, AR112) are not hinged in the rear. Only the NetShelter WX AR100 and AR100HD are hinged in the rear,

      How to use the LXM32M advanced settings in SoMachine?

      In SoMachine, you can add the device under the CanOpen tree as a Lexium 32M or Lexium 32M advanced settings.
      The difference is the DTM available in Lexium 32M advanced settings which allows to connect to the drive without using SoMove (please see attached)

      Video: How do I configure Lexium 32M for control via Modbus RS485?

      Do you do a European socket outlet?

      Yes the part number is 56SO332/6LE

      What is the part number for a 3P 200amp front wired main switch

      T200FA-BK this comes with cover
       
      PDL Book page 124 (2014)

      Error 127 in ION7650 event log

      Issue
      There is error code 127 in ION7650/7550 event log.

      Product Line
      ION7650
      ION7550

      Environment
      Event log

      Resolution
      Error 127 is logged when the ION meter needs to recreate file space for a data recorder.

      The 127 error is logged when there is NO data file present. The ION meter creates the file space for a data recorder and puts a message in the event log telling the user the file was created.

      This is an informational message stating the meter corrected a missing file. This message is usually observed after a framework paste has occurred.

      ETSNZ - How do I wire the BMXDDI1604T discrete IO 125 VDC module for a M340 PLC?

      BMXDDI1604T wiring the 125 VDC module as per the diagram:

      ETSNZ - How do I wire the BMXDRA0804T discrete IO 125 VDC module for a M340 PLC?

      BMXDRA0804T wiring the 125 VDC module as per the diagram:

      What is the part number for duct lid to suit 125 X35  TALplus?

      The part number is PL125CLB

      Do the 755PSMA2 smoke alarms have an insect screen?

      Yes, the new Gen 2 smoke alarms have a 1mm mesh stainless steel high insect screen on the optical sensing chamber. 

      Do you have a 15335 Timer in a 12V DC Timer?

      No unfortunately this is unavailable.

      Electrolyte Levels of All Single-phase Symmetra Battery Systems


      Issue

      What are the electrolyte levels of single phase Symmetra UPS and battery systems?  


      Product Line

      Symmetra Power Array
      Symmetra RM
      Symmetra LX


      Environment

      All serial ranges


      Cause

      This document contains the electrolyte levels found in the battery modules used by each single phase Symmetra system.  This information can sometimes be needed for regulatory compliance in certain jurisdictions.


      Resolution

      Symmetra Power Array 
      SYBATT: Each SYBATT contains (10) 12V 7.2Ah batteries installed in series. The total amount of electrolyte in (1) SYBATT is 0.845 gallons.

      Symmetra 12k RM
      SYBT3: Each SYBT3 contains (10) 12V 7.2Ah batteries installed in series. The total amount of electrolyte in (1) SYBT3 is 0.845 gallons.

      Symmetra 6k RM
      SYBT2: Each SYBT2 contains (10) 12V 5.1 Ah batteries installed in series. The total amount of electrolyte in (1) SYBT2 is 0.55 gallons.

      Symmetra LX
      SYBT5: Each SYBT5 contains (10) 12V 9Ah batteries installed in series. The total amount of electrolyte in (1) SYBT5 is 0.95 gallons.




      Is there a 12v equivalent of the PDL 666TMB24

      No, this is only available in 24v

      Power Supply for 8073/8VHPIR

      8050P12/1600 12V DC @ 1600mA Regulated Power Pack

      What is the part number for the NSX160F Breaker with 125 Amps Trip Unit?

      The part number for the NSX160F Breaker with 125 Amps Trip Unit is "LV430631"

      https://www.schneider-electric.com.au/en/search/LV430631

      What is part number for Red pilot light 12V dc?

      The part number for Red pilot light 12V is part numbers ZBVJ4, ZB5AZ009, ZB5AV043.
       

      Step 7 Motion Library for Lexium 32M via Profibus DP

      Issue:
      Looking for the manual for Step 7 Motion Library for LXM32M on Profibus DP

      Product Line:
      Lexium 32 drives

      Resolution:
      The manual for the Step 7 Motion Library for Lexium 32M via Profibus DP is attached.

      Can the new Twido T2M I/O modules only be configured in TwidoSuite 2.20 and above?

      No.In TwidoSoft, all versions will need to be configured to the old module from the pick list and the same goes for all versions of TwidoSuite less than 2.20.

      Note: Twido was obsoleted in Dec. 2015 and was replaced with the M221 and SoMachine Basic. The M221 will support the TM2 I/O modules in SoMachine Basic.

      What are the characteristics of the XW fan?

      XW+/XW Series Fan Image

      Note: There may be times where the fan needs to be replaced and customer would like to know the ratings of the fan. Physically, the fan's size is 12cm by 12cm.
      Caution: This should only be done safely and by a qualified technician

      What is the sensing distance for the Clipsal 753?

      The effective field of view is circular, approximately 14m diameter, when mounted on a ceiling 2.4m above the floor.
      See Installation instructions for more information

      What voltage is the key tag 6200KT and does it come with a Card?

      It is 24V DC

      Enquire at Assa Abloy 1300 562 587.

      Unfortunately we do not sell the cards.

      Do you sell the center part of a 435VFS15 or the flap as a spare part?

      No, unfortunately we do not sell the center part of a 435VFS15. However we do sell the flap and the rubber seal as a spare part.

      The part numbers are  435VFS15FLAP and 435VF-GSKT.

      What is the part number for the Magelis IPC FRONT-PANEL 12" Touch Screen?

      The part number for the Magelis IPC FRONT- PANEL 12" touch screen is MPCNT20NNN00N.


      Legacy KB System (APS) Data: RESL173884 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Magelis Modular iPC

      Does the E5600 socket meter support a Delta Configuration?

      The 12S socket base is the only base that supports 3 phase 3 wire delta configuration. The 12S socket base does not support current transformers. The 45S socket base is intended for a 4 wire delta with a center tapped leg.
      The E5600 meter supports the following forms and system type below.
      Also attached is a wiring of each socket. 

      Note*: Current transformers can only be used with the class 20 forms. For more information on the current transformers, look to resolution FA212300. 

      Product Line: E5600

      Keywords: Delta, E5600, 3-wire

      Is there a 3 position marked "1, 0, 2" 2 pole cam switch 16A available?

      Yes, the part number for a 3 position marked "1, 0, 2" 2 pole cam switch 16A is a 7GN12/52/U.
      Brief :

       Rotary Cam Switches and Accessories, Rated Thermal Current (Ith) = 12A AC23A rating - 6kW at 415V. Rated Insulation Voltage Ui = 480V. Maximum 16A Fuse (gG/gL) for 3kA short circuit protection, 2 Pole 12A 60° changeover switch with Off marked 1-O-2.

      Some of the key features are:

      • Front mounting
      • AC23A Rating
      • Changeover switch with OFF marked 1-O-2
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=7GN12/52/U​

       

       

       

      AutoCAD drawings for Micom 12x relay

      Below are the drawings for the Micom P12x relay.
      GN0047-1-case 20TE.dwgP12x--518326101-1.pdf


      Legacy KB System (APS) Data: RESL210214 V1.0, Originally authored by DaFr on 01/04/2013, Last Edited by DaFr on 01/04/2013
      Related ranges: Others protection relays

      How many point APS_SENSORS may be connected to the VAMP 121?

      Product Line
      VAMP 121

      Environment
      Sensors

      Resolution
      The VAMP 121 is capable of monitoring up to 10 point APS_SENSORS.

      What is the part number for 125 amp 3 pole din rail mount Circuit breaker?

      Part number for a 3 pole 125 amp "C" curve din rail mount 10kA circuit breaker is A9N18369

      for more information see...

      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9N18369

      User-added image