Series 1244 Machine Cast Fittings, Inspection Elbows, 40mm Galvanised Cast Iron

Series 1244 Machine Cast Fittings, Inspection Elbows, 40mm Galvanised Cast Iron

Series 1244 Machine Cast Fittings, Inspection Elbows, 40mm Galvanised Cast Iron

Item Number: 1244/40

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Series 1244

Surface treatment

galvanised

Physical

Connector type

thread connector

Length

95 mm

Standards

  • AS 1721
  • AS 2052
    • REACh free of SVHC

      Yes

      EU RoHS Directive

      Pro-active compliance (Product out of EU RoHS legal scope)

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Material

      Material

      cast iron

      Others

      Diameter

      40 mm

      Operating angle

      90 °

      Inner radius

      13 mm

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      0.614 kg

      Package 1 Height

      46 mm

      Package 1 width

      92 mm

      Package 1 Length

      92 mm

      Unit Type of Package 2

      BB1

      Number of Units in Package 2

      5

      Package 2 Weight

      2.7 kg

      Package 2 Height

      96 mm

      Package 2 width

      168 mm

      Package 2 Length

      178 mm

      Unit Type of Package 3

      CAR

      Number of Units in Package 3

      25

      Package 3 Weight

      13.5 kg

      Package 3 Height

      190 mm

      Package 3 width

      203 mm

      Package 3 Length

      175 mm
      Show all specifications

      Frequently Asked Questions

      hide show

      Is there are vertical version of the ML2025RCD10C-BG available?

      No,Only available in horizontal.

      Does the 1240/25 series come with gaskets?

      No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
      For more information on this product range please visit the Clipsal web site on the link provided
      https://www.clipsal.com/Trade/search-results?q=1240

      Whati s pitch thread for part number 1245/25?

      Pitch thread is 1.5mm

      What is the replacement on the HMIGTW7354?

      The HMIGTW7354 has been replaced by the HMIDT732 (15' screen display) + HMIG5U (Open Box).

      What is part number for lid to suit 1239/20/4?

      Part number 1239L20 will suit any of 1239/20 series.

      XCSPL XCSTL XCSPR XCSTL safety switches - EC/EU declaration of conformity

      Find attached 2016 update EC/EU declaration of conformity for our XCSPL XCSTL XCSPR XCSTR plastic safety switches. The Low Voltage and EMC directive changed.

      What is the replacement for RE11RMMW Timer?

       The replacement for RE11RMMW Timer is  RE17RMMW

      RE17RMMW 
      time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC 

      For more information see: https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=RE17RMMW

      What is the purpose of the free wheeling diode used in the TM3DQ16R digital replay output card?

      To improve the life time of the contacts, and to protect from potential inductive load damage, it is recommended to connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load.

      Conext SW - Installation/ Wiring issue.

      Issue:

      Customer is installing the Conext SW and wants to confirm the wiring of the AC and DC cabling. 

      Environment:

      Conext SW 2524 120/240 Split-phase (865-2524)
       
      Conext SW 4024 120/240 Split-phase (865-4024)


      Resolution:
       

      See the attached wiring diagrams for the Conext SW and Conext SW-NA.
      Do not mix AC and DC wiring in the same conduit or panel. Consult the applicable installation code for details.
      There are two dual 3/4" /1" trade-size knockouts on the side panel and another two on the bottom panel for AC wiring. Use the same trade size of strain relief as the trade size of the knockout(s) you are using.

       

      What's the difference between the SyMax Model 50 programmable controllers 8005CP50 and 8005CP51?

      The difference between the two SyMax Model 50 programmable controllers is the power voltage rating.
      8005CP50 is a 120/240 VAC Processor Unit.
      8005CP51 is a 24 VDC Processor Unit.


      Legacy KB System (APS) Data: RESL169642 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Sy/Max

      Where can I find programming assistance setting up an Lonworks card on the S-Flex ATV212 drives?

      Issue:
      Where can I find programming assistance setting up an Lonworks card on the S-Flex ATV212 drives?

      Product Line:
      Altivar ATV212 or S-flex 212 drive

      Environment:
      All

      Cause:
      Needs to set up the Lonworks card on the ATV212 drive


      Resolution:
      Reference the ATV212 Lonworks programming manual ATV212_Lonworks_manual_EN_S1A53848_01




       

      Energy Meter shows "Phase Loss" Alarm

      Issue
      Energy meter shows “Phase Loss” alarm on front display.

      Product Line
      Energy meter (EMB and EME series).

      Environment
      Installing/wiring energy meter

      Cause
      If the voltage of any phase is measured as less than 75% of the voltage on any other phase, the display will show PHASE LOSS and indicate the specific phase(s).

      Resolution
      If the energy meter is installed with the proper number of phases (see selection below to determine this) then the phase voltages should be verified. If the number of phases installed is not correct, then the phase loss alarm will be indicated in all operating conditions.

      It’s very important to know the model number of your Energy meter.  
      For example, users see “Phase Loss” error when they use EMB2043 (1 phase, 3 wire) with 1 phase, 2 wire application.

      As a result, it’s very important for users to know their application and use appropriate meter that meets their system type.  Please review the tables below for selecting correct meter.

      Basic 120/240 Volt 208 Wye

      EMB1010 Basic 100A 1 Phase, 2 wire installation 1 CT
      EMB1021 Basic 200A 1 Phase, 2 wire installation 1 CT
      EMB1032 Basic 300A 1 Phase, 2 wire installation 1 CT
      EMB2010 Basic 100A 1 Phase, 3 wire installation 2 CTs
      EMB2021 Basic 200A 1 Phase, 3 wire installation 2 CTs
      EMB2032 Basic 300A 1 Phase, 3 wire installation 2 CTs
      EMB2043 Basic 400A 1 Phase, 3 wire installation 2 CTs
      EMB2083 Basic 800A 1 Phase, 3 wire installation 2 CTs
      EMB3010 Basic 100A 3 Phase, 4 wire installation 3 CTs
      EMB3021 Basic 200A 3 Phase, 4 wire installation 3 CTs
      EMB3032 Basic 300A 3 Phase, 4 wire installation 3 CTs
      EMB3043 Basic 400A 3 Phase, 4 wire installation 3 CTs
      EMB3083 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EMB3084 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EMB3164 Basic 1600A 3 Phase, 4 wire installation 3 CTs


      Extended Range 120/480 Volt Wye

      EME1010 Basic 100A 1 Phase, 2 wire installation 1 CT
      EME1021 Basic 200A 1 Phase, 2 wire installation 1 CT
      EME1032 Basic 300A 1 Phase, 2 wire installation 1 CT
      EME2010 Basic 100A 1 Phase, 3 wire installation 2 CTs
      EME2021 Basic 200A 1 Phase, 3 wire installation 2 CTs
      EME2032 Basic 300A 1 Phase, 3 wire installation 2 CTs
      EME2043 Basic 400A 1 Phase, 3 wire installation 2 CTs
      EME2083 Basic 800A 1 Phase, 3 wire installation 2 CTs
      EME3010 Basic 100A 3 Phase, 4 wire installation 3 CTs
      EME3021 Basic 200A 3 Phase, 4 wire installation 3 CTs
      EME3032 Basic 300A 3 Phase, 4 wire installation 3 CTs
      EME3043 Basic 400A 3 Phase, 4 wire installation 3 CTs
      EME3083 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EME3084 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EME3164 Basic 1600A 3 Phase, 4 wire installation 3 CTs


      NOTE: the meter will operate, however the phase loss alarm will constantly be present if the improper meter is in use.
      Show More