elbow insp galv cond 25mm

Series 1244 Machine Cast Fittings, Inspection Elbows, 25mm Galvanised Cast Iron

Catalogue Number: 1244/25
elbow insp galv cond 25mm
Retail
$68.37
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Range of product
Series 1244
Material
cast iron
Surface treatment
galvanised
Diameter
25 mm
Connector type
thread connector
Operating angle
90 °
Length
67 mm
Inner radius
12 mm
Standards
  • AS 2052
  • AS 1721
    • Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      274 g
      Package 1 Height
      40 mm
      Package 1 width
      45 mm
      Package 1 Length
      92 mm
      Unit Type of Package 2
      BB1
      Number of Units in Package 2
      10
      Package 2 Weight
      2.916 kg
      Package 2 Height
      96 mm
      Package 2 width
      176 mm
      Package 2 Length
      177 mm
      Unit Type of Package 3
      CAR
      Number of Units in Package 3
      50
      Package 3 Weight
      14.4 kg
      Package 3 Height
      190 mm
      Package 3 width
      203 mm
      Package 3 Length
      475 mm
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Frequently Asked Questions

      hide show

      Whati s pitch thread for part number 1245/25?

      Pitch thread is 1.5mm

      Does the 1240/25 series come with gaskets?

      No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
      For more information on this product range please visit the Clipsal web site on the link provided
      https://www.clipsal.com/Trade/search-results?q=1240

      What is the thread type on a 1235/25?

      The thread type on a 1235/25 is BS - British Standard.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=1235/25 

      What potentiometer should I use for ATV61?

      Schneider Electric part No. SZ1RV1202

      Is there 125x125 mini trunking available.

      no, biggest mini trunking size available is 150x75

      What is the part number for a plug to suit the 240/25?

      The part number for a plug to suit the 240/25/3 is a 220/25.
       

      What is the dimension of 1264/2M, 25mm (male) to 20mm (female) brass reducer?

      Dimensions of 1264/2M are as follows:
      A = 25mm
      B = 21mm
      C = 16mm


      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=1264/2M

      What is part number for lid to suit 1239/20/4?

      Part number 1239L20 will suit any of 1239/20 series.

      Is there an extension ring to suit the 343?

      Yes, there is the 93ER and also the 249/12 or 249/25.

      SRT 8 or 10kVA reports Error P.11 or DC Bus Soft Start or event codes 124/125

      Issue: The UPS reports P.11 or DC Bus Soft Start - event 124/125



      Product Line: SRT 8-10kVA Models 

      Resolution:
      Clear the Alarm. Turn the output ON again. If the problem persists, Brain dead the UPS. If the alarm reoccurs, perform a UPS Firmware upgrade to the latest 04.7 revision that addressed these issues. For complete upgrade instructions please refer to FA164737.
       
      Release Notes (UPS 04.7):
      ========================
      1. Improved system performance of transitions between Online and Bypass operation modes.
      2. Improved system behaviour for three phase input configurations to reduce transitions to battery under certain input feed conditions.
      3. Improved system behaviour to eliminate false detection of DC bus under voltage alarm under certain conditions.
      4. Improved system handling for certain AC input conditions during system start-up.

      Could not remove directory \usr\Cfg message when upgrading M241/251 firmware

      • When upgrading using Controller Assistant and USB cable, error message "Could not remove directory \usr\Cfg" is displayed.
      • When upgrading using SD card "Delete "/usr/*" (line 1) returned cleaning error" appears in SCRIPT.log file.

      This is because some corrupted files can not be deleted.
      To delete these files " Format "/usr" " should be added to SD card script.

      In firmwares starting from v4.0.2.52 " Format "/usr" " is added automatically by Controller Assistant when generating SD cards.
       

      What is the dimension of 1260025 TMX-4E hollow wall anchor cavity fixing with screw?

      The dimension of 1260025 TMX-4E is 14mm (diameter) x 47mm (length). 1260025 is cavity fixing including fully threaded screw with combi-head and Phillips cross-slot.
      Benefits
      • Captive fixing – stays fixed even when the screw is not tightened
      • Anti-rotation design
      • Pre-assembled screw
      • High load values
      • Fire-resistant
      • Ideal for overhead cavity fixing
      Material and Operative Data:
      Material cavity fixing Expanding part: electroplated sheet metal
      Screw: electroplated steel
      Material mounting tool: Steel and plastic
      Temperature range:  –40°C to 80°C
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=1260025
      User-added image
      Show More