elbow insp galv h/d gaskets

General Accessories Elbow Insp Galv H/D Gaskets

Catalogue Number: 1244/20GT
elbow insp galv h/d gaskets
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Material
cast iron
Surface treatment
electro-zinc
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Specifications

  • Corporate Marketing

Frequently Asked Questions

hide show

What is part number for lid to suit 1239/20/4?

Part number 1239L20 will suit any of 1239/20 series.

How to control an ATV61 / ATV71 with a M340 CPU built-in Ethernet port using the DATA_EXCH function

The attached document describes an application using a M340 CPU with a built-in Ethernet port connected to an ATV71 Ethernet card VW3A3310D and using the DATA_EXCH function. The M340 will be communicating with the IO Scanner service in the drive.
 

What would cause a Quantum 140CPS11100 power supply to not power up?

The Quantum 140CPS11100 power supply that has a PV 01 or higher now require a jumper on pins 3 and 4 on the terminal strip for 115 VAC operations. If this jumper is not installed, it will be set for 220 VAC operations. Any power supply with a PV less than 1 did not require the jumpers.

Note: The Quantum line is obsolete 12/1/2018 and the recommended replacement is the M580 with the x80 I/O, for further information on this contact your local distributor.


Can my XW+ inverter qualify an input of 120V/208V 60Hz?

XW+ inverters input parameters

The XW+ and XW inverters, either the XW6848, XW5548, XW6048, XW4548 or the XW4024, require an input of 120V/240V 60Hz. When the input is 120V/208V 60Hz, is going to be a three phase setup. The reason for this is because the XW+ and XW unit require a phase difference between line 1 (L1) and line 2 (L2) of 180 degrees, on a three phase setup, L1 and L2 are 120 degrees offset. This causes the inverter to not recognize the input at all. The inverter can only accept input from 120/208V wye source if you have 3 inverters (1 per phase), each "converted" to 120V, and then configured for 3-phase multi-unit operation.

Single Phase Diagram:



Three Phase Diagram:


 

Video: Setting Up DTM Browser for ModbusTCP Communication

Issue:
Is there an example of adding a ModbusTCP device using the Unity DTM Browser ?
 
Product Line:
M580 and M340 NOC modules
 
Environment:
Unity Pro
 
Resolution:
Yes, attached is an example that explains the steps to adding a ModbusTCP device through the Unity DTM Browser.

 

Does the modicon M340 PLC have a ruggedized version 12-slot chassis?

Title
12 Slot Ruggedized Rack
 
Issue
Does the modicon M340 PLC have a ruggedized version 12-slot chassis?
 
Product Line
M340
 
Resolution
Yes... Part# BMXXBP1200H
Modicon_M340_BMXXBP1200H Data Sheet.zipModicon_M340_BMXXBP1200H Data Sheet.zip


M340 Ethernet services available when using different memory cards.

Title
M340 Ethernet services availablity 
 
Issue
M340 Ethernet services available when using different memory cards.
 
Product Line
M340.
 
Resolution
The following table lists the services that are available when the memory card is inserted in various Modicon M340 modules:


Is it possible to change IP address of meters, gateways or communication connections in System Manager Software (SMS) for existing devices, and keep historical data intact?

How to change the IP address of a meter, gateway or communication connection in SMS:
- Take the system offline by clicking on File> Offline
- Click Setup > Communications Connection. The Setup Communications Connection dialog box displays.
- Click on the communication connection that needs to be changed, and click on Configure.
- Change the IP address for the communication connection.
- Click Ok after making the changes, and put the system back online
- Click on File>Online>System

171CCC98030 - How do I reset the IP address of the unit back to the default IP address.

Momentum M1E:
Title
171CCC98030 Reset capability
 
Issue
How do I reset the IP address of the 171CCC98030 back to the default IP address
 
Product Line
Momentum.
 
Resolution
Once the Momentum M1E processor has had a project download and flashed, it can not be reset back to default settings.

 

Minimum parts requirements for adding ‘one’ 140NRP95400 Fiber Optic Repeaters modules to replace a stand alone 490NRP95400 modules.

Title
Replacing 490NRP95400 with a 140NRP95400 Fiber Optic Repeaters modules
 
Issue
Parts requirements for adding ‘one’ 140NRP95400 Fiber Optic Repeaters modules
 
Product Line
Modbus Plus
 
Resolution
 Backplane and PSU for ‘one’ NRP repeater system
1-  Quantum Three position back plane Part# 140XBP00300
1-  Quantum Power supply 115..230VAC 3A Part# 140CPS11100
 

What size fuses are used in the ATS48 for the control circuit going to CL1 and CL2?

Issue:
What size fuses are used in the ATS48 for the control circuit going to CL1 and CL2?

Product Line:
Altistart 48, ATS48

Environment:
All open style units.  All models, All Serial numbers.

Cause:
Selection of Fuses.

Resolution:

ATS48D17Y and ATS48D22Y we recommend Class CC 600V 0.5 A fuses.

ATS48D32Y, ATS48D38Y, ATS48D47Y, ATS48D62Y, ATS48D75Y, ATS48D88Y, ATS48C11Y, ATS48C14Y, and ATS48C17Y we recommend Class CC 600V 0.6 A fuses.

ATS48C21Y, ATS48C24Y, and ATS48C32Y we recommend Class CC 600V 1.0 A fuses.

ATS48C41Y, ATS48C48Y, ATS48C59Y, ATS48C66Y, ATS48C79Y, ATS48M10Y and ATS48M12Y we recommend Class CC 600V, 1.5 A fuses.

Information provided in Table 31 page 83) of document S1A37491 Altistart 48 Y-range Soft Start Controllers Instruction Bulletin.

What is the minimum clearance for mounting Twido Controllers in a cabinet?

Minimum Clearances for a Compact Controller and Expansion I/O Modules. In order to maintain a natural circulation of air around the Compact controller and expansion I/O modules in a control panel, observe the minimum clearances shown in the figures below.

Minimum Clearances for a Modular Controller and Expansion I/O Modules. In order to maintain a natural circulation of air around the Modular controller and expansion I/O modules in a control panel, observe the minimum clearances shown in the figures below.

 


Note: Twido was made obsolete 12/1/2015 and has been replaced with the M221. The Twido program can be imported into the M221 SoMachine Basic software and the dimensions are the same for the M221 as the Twido. For further information on this contact your local distributor or Schneider sales office.
Show More