nipple steel cond 40mm z/pl

Cable Management Machined Brass, Steel Couplings, 40mm Steel Nipple

Catalogue Number: 1243S40
nipple steel cond 40mm z/pl
Retail
$39.77
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Range of product
Series 1243
Material
steel
Connector type
thread connector
Product destination
diameter: 40-40 mm tube
Length
38-38 mm
Standards
  • AS 1721
  • CS 792/S
  • AS 2052
    • Package 1 Weight
      0.072 kg
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Frequently Asked Questions

      hide show

      Can you use a XBTZGMBP with a HMIGTO ?

      Yes

      Is there a difference in depth of the swing frame cabinets to the non swing frame variants?

      Swing frame adds an ecxtra 50mm depth to cabinet.

      What is the part number for a 20mm steel conduit plug?

      The part number  for a 20mm brass plug for steel conduit is 1220S20.

      What are the torque specifications for AB1VV435U and AB1VVN1035U terminal blocks?

      Issue:
      What are the torque specifications for AB1VV435U and AB1VVN1035U terminal blocks?
      Product Line:
      IEC Terminal Blocks 
       
      Environment:
      AB1VV Box Lug Blocks
      Cause:
      Assembly/installation, wiring
      Resolution:
      The torque specification for the AB1VV435U is .5-.7 N-m(4.4-6.2 inch-lbs).  and for the AB1VVN1035U, it is 2-2.5 N-m (17.6-22 inch-lbs).
      CTA-ID : 2043140

      What is the replacement for RE11RMMW Timer?

       The replacement for RE11RMMW Timer is  RE17RMMW

      RE17RMMW 
      time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC 

      For more information see: https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=RE17RMMW

      What are the certification of the Altivar drives?

      Issue:
      What are the certification of the Altivar drives?

      Product Line:
      ATV32, ATV61, ATV312, ATV12, ATV71 , ATV31, ATV212, ATV21, ATS48, ATS22, ATS01

      Environment:
      All Serial numbers

      Cause:
      N/A

      Resolution
      For a list of certificates see the attached document.

      Conext SW - Installation/ Wiring issue.

      Issue:

      Customer is installing the Conext SW and wants to confirm the wiring of the AC and DC cabling. 

      Environment:

      Conext SW 2524 120/240 Split-phase (865-2524)
       
      Conext SW 4024 120/240 Split-phase (865-4024)


      Resolution:
       

      See the attached wiring diagrams for the Conext SW and Conext SW-NA.
      Do not mix AC and DC wiring in the same conduit or panel. Consult the applicable installation code for details.
      There are two dual 3/4" /1" trade-size knockouts on the side panel and another two on the bottom panel for AC wiring. Use the same trade size of strain relief as the trade size of the knockout(s) you are using.

       

      What's the difference between the SyMax Model 50 programmable controllers 8005CP50 and 8005CP51?

      The difference between the two SyMax Model 50 programmable controllers is the power voltage rating.
      8005CP50 is a 120/240 VAC Processor Unit.
      8005CP51 is a 24 VDC Processor Unit.


      Legacy KB System (APS) Data: RESL169642 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Sy/Max

      What is the replacement lens cap for ZB2BW extended head push button?

      Issue:
      What is the replacement lens cap for ZB2BW extended head push button?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product selection

      Resolution:
      The ZB2 product line is discontinued.  The replacement heads are no longer available

      ZB2BW931 - White
      ZB2BW933 - Green
      ZB2BW934 - Red
      ZB2BW935 - Ambler
      ZB2BW936 - Blue
      ZB2BW937 - Clear

      Will the Compact NSX breaker be for sale in the USA or Canada?

      Issue:
      Where can I buy a Compact NSX breaker?

      Product Line:
      Circuit Breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

      If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

      For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
      https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page

      XW Won't qualify generator.

      Issue:

      XW inverter charger will not qualify AC generator. AC IN light blinks
      AC input qualification, overloading the generator, unable to sustain battery charging and and running loads (multi-tasking)


      Environment:

      XW 4024/4548/6048 with AC generator


      Resolution:

      1) Ensure generator is split phase 120/240, not 120 monophase or 120/208V. Voltage from (L1 to N) and (N to L2) should add up exactly to (L1 to L2) voltage
      3) Recommended, size your generator 2 times the rating of the XW system.
      2) Ensure no neutral to ground bond in Generator
      3) Connect gen output to AC2, not AC1 and open up AC2 parameters in XW advanced settings - ac settings menu
      4) Reduce max charge rate in XW
      5) If Kohler RES series generator, see  Solution 1179

      Cause:

      1) XW can only connect to splt-ph 120/240 unless converted to monophase 
      2) Potential ground loop
      3) AC2 qualification parameter window much wider than AC1
      4) Gen being overloaded by combination of house loads and XW charger.

      Can a circuit breaker be operated at a voltage less than the voltage marked on the breaker?

      Inquiry:
      Is it OK to apply a circuit breaker on a voltage system rated lower than the rating of the breaker?

      Product Line:
      MCB and MCCB circuit breakers

      Cause:
      Circuit breakers are typically marked only with a few standard voltages, while other voltage systems exist.

      Resolution:
      Yes. According to 2011 NEC article  240.83(E), a circuit breaker may be used at voltages equal to or less than its voltage rating. 
      When applied on a system of lower voltage than marked, he interrupting rating is equal to the next highest marked interrupting rating. 
      The only exceptions to application at less than rated voltage are:
      1. QO and HOM -GFI, -EPD, -AFI, -CAFI, and DF circuit breakers must be applied on 120/240 Vac systems only (they need over 100 Vac to power the electronic modules)
      2. EHB-EPD and EDB-EPD type breakers which must be applied on 480Y/277 systems only

      NOTE:  Circuit breakers marked with DC ratings only are not suitable for application on AC systems, and circuit breakers marked with AC ratings only are not suitable for application on DC systems.
      Show More