coupling steel con 40mm z/pl

Cable Management Machined Brass, 40Mm Steel Coupling, Galvanised

Catalogue Number: 1242S40
coupling steel con 40mm z/pl
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Material
steel
Surface treatment
cast galvanised
Surface finish
polished
Connector type
thread connector
Product destination
diameter: 40-40 mm tube
Length
48.5-48.5 mm
Standards
  • CS 792/S
  • AS 2052
  • AS 1721
    • REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      How to remove or install PDL3208

      Please see attached instruction sheet - complete with cleaning instructions.

      What is the part number for a 20mm steel conduit plug?

      The part number  for a 20mm brass plug for steel conduit is 1220S20.

      Does the M340 BMXPRA0100 Remote I/O module come with an SD card on delivery?

      Yes. The standard SD card part# BMXRMS008MP is included when purchasing the unit BMXPRA0100 Remote I/O module.

      What is the replacement for RE11RMMW Timer?

       The replacement for RE11RMMW Timer is  RE17RMMW

      RE17RMMW 
      time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC 

      For more information see: https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=RE17RMMW

      Conext SW - Installation/ Wiring issue.

      Issue:

      Customer is installing the Conext SW and wants to confirm the wiring of the AC and DC cabling. 

      Environment:

      Conext SW 2524 120/240 Split-phase (865-2524)
       
      Conext SW 4024 120/240 Split-phase (865-4024)


      Resolution:
       

      See the attached wiring diagrams for the Conext SW and Conext SW-NA.
      Do not mix AC and DC wiring in the same conduit or panel. Consult the applicable installation code for details.
      There are two dual 3/4" /1" trade-size knockouts on the side panel and another two on the bottom panel for AC wiring. Use the same trade size of strain relief as the trade size of the knockout(s) you are using.

       

      What's the difference between the SyMax Model 50 programmable controllers 8005CP50 and 8005CP51?

      The difference between the two SyMax Model 50 programmable controllers is the power voltage rating.
      8005CP50 is a 120/240 VAC Processor Unit.
      8005CP51 is a 24 VDC Processor Unit.


      Legacy KB System (APS) Data: RESL169642 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Sy/Max

      What would be the replacement to the older ATV31 S-Flex drive?

      Issue:
      What would be the replacement to the older ATV31 S-Flex drive?

      Product Line:
      ATV31 S-Flex

      Environment: 

      All

      Answer To Customer: 
      If the application is low torque such as fan or pump then an ATV212 S-Flex would be a good replacement.
      If the application is moderate or heavy torque, then please contact your local Product Application Engineer (PAE) or local distributor for enclosed drive selection.

      How do you display motor current on the ATV312 drives?

      Issue:
      Display motor current on the ATV312 drives

      Product Line:
      Altivar ATV312

      Environment:
      All

      Cause:
      Needs to display motor current on the main display.

      Resolution:
      Programming
      SUP menu
      Enter
      Arrow down to LCR enter
      now the drive will display motor current. 
      If you want the drive to always show motor current hit Enter again.

      No access to web agent using TLS 1.1 or TLS 1.2 with PowerChute Business Edition 9.0.1, 9.1.0, 9.0.2

      Issue:
      PowerChute Business Edition 9.0.1, 9.1.0 and 9.0.2 is packaged with JRE 6. JRE 6 is not compatible with TLS 1.1 or TLS 1.2

      Product Line: 
      PowerChute Business Edition  versions 9.0.1, 9.1.0 and 9.0.2

      Environment:
      OS: Linux, Solaris, Windows x64, x86

      Cause:
      JRE 6 is not compatible with TLS 1.1 or TLS 1.2 see the following for more info: https://docs.oracle.com/javase/7/docs/technotes/guides/security/SunProviders.html

      Solution:
      Upgrade the version of JRE used by PowerChute to a version greater than 6
      1 – Install a standalone x86 Java JRE (minimum JRE version 7)
           Note: On Linux, the RPM Package Manager installs the JRE to the /usr/java/ directory.

      2 – Download the attached JRE Config Tool:   


      3 – Run the JRE Config Tool to change the location of the Java JRE used by PowerChute to  the  JRE installed in step 1.
       

      XW Won't qualify generator.

      Issue:

      XW inverter charger will not qualify AC generator. AC IN light blinks
      AC input qualification, overloading the generator, unable to sustain battery charging and and running loads (multi-tasking)


      Environment:

      XW 4024/4548/6048 with AC generator


      Resolution:

      1) Ensure generator is split phase 120/240, not 120 monophase or 120/208V. Voltage from (L1 to N) and (N to L2) should add up exactly to (L1 to L2) voltage
      3) Recommended, size your generator 2 times the rating of the XW system.
      2) Ensure no neutral to ground bond in Generator
      3) Connect gen output to AC2, not AC1 and open up AC2 parameters in XW advanced settings - ac settings menu
      4) Reduce max charge rate in XW
      5) If Kohler RES series generator, see  Solution 1179

      Cause:

      1) XW can only connect to splt-ph 120/240 unless converted to monophase 
      2) Potential ground loop
      3) AC2 qualification parameter window much wider than AC1
      4) Gen being overloaded by combination of house loads and XW charger.

      Can a circuit breaker be operated at a voltage less than the voltage marked on the breaker?

      Inquiry:
      Is it OK to apply a circuit breaker on a voltage system rated lower than the rating of the breaker?

      Product Line:
      MCB and MCCB circuit breakers

      Cause:
      Circuit breakers are typically marked only with a few standard voltages, while other voltage systems exist.

      Resolution:
      Yes. According to 2011 NEC article  240.83(E), a circuit breaker may be used at voltages equal to or less than its voltage rating. 
      When applied on a system of lower voltage than marked, he interrupting rating is equal to the next highest marked interrupting rating. 
      The only exceptions to application at less than rated voltage are:
      1. QO and HOM -GFI, -EPD, -AFI, -CAFI, and DF circuit breakers must be applied on 120/240 Vac systems only (they need over 100 Vac to power the electronic modules)
      2. EHB-EPD and EDB-EPD type breakers which must be applied on 480Y/277 systems only

      NOTE:  Circuit breakers marked with DC ratings only are not suitable for application on AC systems, and circuit breakers marked with AC ratings only are not suitable for application on DC systems.

      How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

      Issue:
      Implementing a hardwire stepdown transformer in a 208v or 240v environment


      Product Line:

      Smart-UPS / Symmetra

      Environment:

      APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

      Cause:

      Unbalanced UPS outputs require a stepdown transformer to power 120v loads


      Resolution:

      This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

      The wiring block outputs are as follows:


      For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

      The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



       Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

      Lost Neutral - effects on loads and UL1449

      Issue:

      Lost Neutral - effects on loads and UL1449

      Product Line:

      All Back-UPS, Back-UPS PRO and Personal Surge

      Environment:

      Lost Neutral in electrical infrastructure.

      Cause:

      Lifted neutral at utility panel.

      Resolution:

      In a typical balanced load with all loads using the neutral return and the neutral is severed, the voltage from each Phase appears across each load and is added on itself. This is a typical fault condition. Underwriter's Laboratories realized that this fault condition is common and it is not up to the Surge Protection Industry to prevent these failures but in the event of this common failure, UL addressed this condition by requiring all Surge Protectors to pass a fault of 240 VAC at different current levels to simulate different loads. These currents are: 125 mA rms. 500 mA rms. 2.5 A rms. and 5 A rms. They also require an unlimited current test (1000 A rms. or greater). 240 VAC is used because most household wiring is 120/240 3 wire single phase and a lost neutral produces 240 VAC. The unit during this test has cheesecloth wrapped around it. The unit may not emit flame nor can it char the cheesecloth nor can it create an opening in the housing that exposes live metal parts large enough for a child's finger to be inserted. After the test, the unit may not allow leakage currents of > 0.5 mA from Line to Ground and Neutral to Ground also it must withstand a dielectric voltage of 240 VAC for minute between each protected mode. Our units have passed this stringent test requirement in order to get UL recognition and to insure the safety of our customer's lives and property.
       

      Can a 3-pole breaker be used in a 2-pole application?

      Issue:
      Can a three pole breaker be used in either a two pole or a single phase application?

      Product Line:
      MCCB

      Environment:
      Powerpact and Masterpact

      Resolution:
      • A 3p breaker can be used on a 3 phase system using either 2 or 3 poles.
      • A 3p breaker can be used on a 1 phase system only if indicated by the markings as noted below.
      For reference:
      • Per NEC article 240.85: "A circuit breaker with a straight voltage rating, such as 240V or 480V, shall be permitted to be applied in a circuit in which the nominal voltage between any two conductors does not exceed the circuit breaker’s voltage rating."
      • According to UL's White book, "3–pole circuit breakers are suitable for use on 3-phase systems only, unless marked to indicate use on 1-phase systems, such as, “For 1–phase connections, use two outside poles,” or an equivalent statement. A 3-pole breaker used in place of a 2-pole breaker on a 3-phase system, such as a 2-pole breaker used in a branch circuit that is actually two legs of a 3-phase system, is acceptable without the 3-pole breaker being specifically marked."

      Powerpact P
      • The 3-pole P-frame breaker has a marking on the cover that states "single phase any 2 poles". Therefore on a 120/240Vac system, it is ok to use any 2 poles of a 3 pole P-frame breaker.
      • This breaker marking correlates with the wiring diagram markings of the M and P breaker enclosure, which shows both 2p and 3p applications.
      Powerpact L
      • The 3-pole L-frame breaker does NOT have a marking for single phase systems. Therefore on the 120/240Vac system, it is NOT ok to use a 3 pole L-frame breaker.
      • This marking correlates with the wiring diagram of the L breaker enclosure, which shows only 3p applications.
      Powerpact H and J
      • Three-pole Powerpact H and J-frame thermal-magnetic breakers are marked for single phase use
      • Three-pole Powerpact H and J-frame Micrologic breakers with standard trip units (U31X and U33X) are marked for single-phase use
      • Three-pole Powerpact H and J-frame Micrologic breakers with Ammeter and Energy trip units (U43X, U44X, U53X and U54X) are NOT marked for single-phase use.

      Energy Meter shows "Phase Loss" Alarm

      Issue
      Energy meter shows “Phase Loss” alarm on front display.

      Product Line
      Energy meter (EMB and EME series).

      Environment
      Installing/wiring energy meter

      Cause
      If the voltage of any phase is measured as less than 75% of the voltage on any other phase, the display will show PHASE LOSS and indicate the specific phase(s).

      Resolution
      If the energy meter is installed with the proper number of phases (see selection below to determine this) then the phase voltages should be verified. If the number of phases installed is not correct, then the phase loss alarm will be indicated in all operating conditions.

      It’s very important to know the model number of your Energy meter.  
      For example, users see “Phase Loss” error when they use EMB2043 (1 phase, 3 wire) with 1 phase, 2 wire application.

      As a result, it’s very important for users to know their application and use appropriate meter that meets their system type.  Please review the tables below for selecting correct meter.

      Basic 120/240 Volt 208 Wye

      EMB1010 Basic 100A 1 Phase, 2 wire installation 1 CT
      EMB1021 Basic 200A 1 Phase, 2 wire installation 1 CT
      EMB1032 Basic 300A 1 Phase, 2 wire installation 1 CT
      EMB2010 Basic 100A 1 Phase, 3 wire installation 2 CTs
      EMB2021 Basic 200A 1 Phase, 3 wire installation 2 CTs
      EMB2032 Basic 300A 1 Phase, 3 wire installation 2 CTs
      EMB2043 Basic 400A 1 Phase, 3 wire installation 2 CTs
      EMB2083 Basic 800A 1 Phase, 3 wire installation 2 CTs
      EMB3010 Basic 100A 3 Phase, 4 wire installation 3 CTs
      EMB3021 Basic 200A 3 Phase, 4 wire installation 3 CTs
      EMB3032 Basic 300A 3 Phase, 4 wire installation 3 CTs
      EMB3043 Basic 400A 3 Phase, 4 wire installation 3 CTs
      EMB3083 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EMB3084 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EMB3164 Basic 1600A 3 Phase, 4 wire installation 3 CTs


      Extended Range 120/480 Volt Wye

      EME1010 Basic 100A 1 Phase, 2 wire installation 1 CT
      EME1021 Basic 200A 1 Phase, 2 wire installation 1 CT
      EME1032 Basic 300A 1 Phase, 2 wire installation 1 CT
      EME2010 Basic 100A 1 Phase, 3 wire installation 2 CTs
      EME2021 Basic 200A 1 Phase, 3 wire installation 2 CTs
      EME2032 Basic 300A 1 Phase, 3 wire installation 2 CTs
      EME2043 Basic 400A 1 Phase, 3 wire installation 2 CTs
      EME2083 Basic 800A 1 Phase, 3 wire installation 2 CTs
      EME3010 Basic 100A 3 Phase, 4 wire installation 3 CTs
      EME3021 Basic 200A 3 Phase, 4 wire installation 3 CTs
      EME3032 Basic 300A 3 Phase, 4 wire installation 3 CTs
      EME3043 Basic 400A 3 Phase, 4 wire installation 3 CTs
      EME3083 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EME3084 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EME3164 Basic 1600A 3 Phase, 4 wire installation 3 CTs


      NOTE: the meter will operate, however the phase loss alarm will constantly be present if the improper meter is in use.

      Are EasyPact CVS circuit breakers for sale in the USA or Canada?

      Product Line:
      EasyPact CVS circuit breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.

      Will the Compact NSX breaker be for sale in the USA or Canada?

      Issue:
      Where can I buy a Compact NSX breaker?

      Product Line:
      Circuit Breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

      If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

      For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
      https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page

      Are EasyPact EZC or EZD circuit breakers for sale in the USA or Canada?

      Product Line:
      EasyPact EZC and EZD circuit breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the EasyPact EZC or EZD circuit breaker line in North America.