coupling steel con 40mm z/pl

Cable Management Machined Brass, 40mm Steel Coupling, Galvanised

Catalogue Number: 1242S40
coupling steel con 40mm z/pl
Retail
$79.08
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Material
steel
Surface treatment
cast galvanised
Surface finish
polished
Connector type
thread connector
Product destination
diameter: 40-40 mm tube
Length
48.5-48.5 mm
Standards
  • CS 792/S
  • AS 2052
  • AS 1721
    • Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      311 g
      Package 1 Height
      55 mm
      Package 1 width
      50 mm
      Package 1 Length
      55 mm
      Unit Type of Package 2
      BB1
      Number of Units in Package 2
      10
      Package 2 Weight
      3.11 kg
      Package 2 Height
      110 mm
      Package 2 width
      124 mm
      Package 2 Length
      170 mm
      Unit Type of Package 3
      CAR
      Number of Units in Package 3
      30
      Package 3 Weight
      9.33 kg
      Package 3 Height
      117 mm
      Package 3 width
      250 mm
      Package 3 Length
      310 mm
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Frequently Asked Questions

      hide show

      How to remove or install PDL3208

      Please see attached instruction sheet - complete with cleaning instructions.

      What is the part number for a 20mm steel conduit plug?

      The part number  for a 20mm brass plug for steel conduit is 1220S20.

      Does the M340 BMXPRA0100 Remote I/O module come with an SD card on delivery?

      Yes. The standard SD card part# BMXRMS008MP is included when purchasing the unit BMXPRA0100 Remote I/O module.

      What is the replacement for RE11RMMW Timer?

       The replacement for RE11RMMW Timer is  RE17RMMW

      RE17RMMW 
      time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC 

      For more information see: https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=RE17RMMW

      Conext SW - Installation/ Wiring issue.

      Issue:

      Customer is installing the Conext SW and wants to confirm the wiring of the AC and DC cabling. 

      Environment:

      Conext SW 2524 120/240 Split-phase (865-2524)
       
      Conext SW 4024 120/240 Split-phase (865-4024)


      Resolution:
       

      See the attached wiring diagrams for the Conext SW and Conext SW-NA.
      Do not mix AC and DC wiring in the same conduit or panel. Consult the applicable installation code for details.
      There are two dual 3/4" /1" trade-size knockouts on the side panel and another two on the bottom panel for AC wiring. Use the same trade size of strain relief as the trade size of the knockout(s) you are using.

       

      What's the difference between the SyMax Model 50 programmable controllers 8005CP50 and 8005CP51?

      The difference between the two SyMax Model 50 programmable controllers is the power voltage rating.
      8005CP50 is a 120/240 VAC Processor Unit.
      8005CP51 is a 24 VDC Processor Unit.


      Legacy KB System (APS) Data: RESL169642 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Sy/Max

      What would be the replacement to the older ATV31 S-Flex drive?

      Issue:
      What would be the replacement to the older ATV31 S-Flex drive?

      Product Line:
      ATV31 S-Flex

      Environment: 

      All

      Answer To Customer: 
      If the application is low torque such as fan or pump then an ATV212 S-Flex would be a good replacement.
      If the application is moderate or heavy torque, then please contact your local Product Application Engineer (PAE) or local distributor for enclosed drive selection.

      How do you display motor current on the ATV312 drives?

      Issue:
      Display motor current on the ATV312 drives

      Product Line:
      Altivar ATV312

      Environment:
      All

      Cause:
      Needs to display motor current on the main display.

      Resolution:
      Programming
      SUP menu
      Enter
      Arrow down to LCR enter
      now the drive will display motor current. 
      If you want the drive to always show motor current hit Enter again.

      No access to web agent using TLS 1.1 or TLS 1.2 with PowerChute Business Edition 9.0.1, 9.1.0, 9.0.2

      Issue:
      PowerChute Business Edition 9.0.1, 9.1.0 and 9.0.2 is packaged with JRE 6. JRE 6 is not compatible with TLS 1.1 or TLS 1.2

      Product Line: 
      PowerChute Business Edition  versions 9.0.1, 9.1.0 and 9.0.2

      Environment:
      OS: Linux, Solaris, Windows x64, x86

      Cause:
      JRE 6 is not compatible with TLS 1.1 or TLS 1.2 see the following for more info: https://docs.oracle.com/javase/7/docs/technotes/guides/security/SunProviders.html

      Solution:
      Upgrade the version of JRE used by PowerChute to a version greater than 6
      1 – Install a standalone x86 Java JRE (minimum JRE version 7)
           Note: On Linux, the RPM Package Manager installs the JRE to the /usr/java/ directory.

      2 – Download the attached JRE Config Tool:   


      3 – Run the JRE Config Tool to change the location of the Java JRE used by PowerChute to  the  JRE installed in step 1.
       

      XW Won't qualify generator.

      Issue:

      XW inverter charger will not qualify AC generator. AC IN light blinks
      AC input qualification, overloading the generator, unable to sustain battery charging and and running loads (multi-tasking)


      Environment:

      XW 4024/4548/6048 with AC generator


      Resolution:

      1) Ensure generator is split phase 120/240, not 120 monophase or 120/208V. Voltage from (L1 to N) and (N to L2) should add up exactly to (L1 to L2) voltage
      3) Recommended, size your generator 2 times the rating of the XW system.
      2) Ensure no neutral to ground bond in Generator
      3) Connect gen output to AC2, not AC1 and open up AC2 parameters in XW advanced settings - ac settings menu
      4) Reduce max charge rate in XW
      5) If Kohler RES series generator, see  Solution 1179

      Cause:

      1) XW can only connect to splt-ph 120/240 unless converted to monophase 
      2) Potential ground loop
      3) AC2 qualification parameter window much wider than AC1
      4) Gen being overloaded by combination of house loads and XW charger.

      Can a circuit breaker be operated at a voltage less than the voltage marked on the breaker?

      Inquiry:
      Is it OK to apply a circuit breaker on a voltage system rated lower than the rating of the breaker?

      Product Line:
      MCB and MCCB circuit breakers

      Cause:
      Circuit breakers are typically marked only with a few standard voltages, while other voltage systems exist.

      Resolution:
      Yes. According to 2011 NEC article  240.83(E), a circuit breaker may be used at voltages equal to or less than its voltage rating. 
      When applied on a system of lower voltage than marked, he interrupting rating is equal to the next highest marked interrupting rating. 
      The only exceptions to application at less than rated voltage are:
      1. QO and HOM -GFI, -EPD, -AFI, -CAFI, and DF circuit breakers must be applied on 120/240 Vac systems only (they need over 100 Vac to power the electronic modules)
      2. EHB-EPD and EDB-EPD type breakers which must be applied on 480Y/277 systems only

      NOTE:  Circuit breakers marked with DC ratings only are not suitable for application on AC systems, and circuit breakers marked with AC ratings only are not suitable for application on DC systems.

      How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

      Issue:
      Implementing a hardwire stepdown transformer in a 208v or 240v environment


      Product Line:

      Smart-UPS / Symmetra

      Environment:

      APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

      Cause:

      Unbalanced UPS outputs require a stepdown transformer to power 120v loads


      Resolution:

      This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

      The wiring block outputs are as follows:


      For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

      The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



       Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

      Show More