coupling steel con 32mm z/pl

Cable Management Machined Brass, 32Mm Steel Coupling, Zinc Plated

Catalogue Number: 1242S32
coupling steel con 32mm z/pl
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Material
steel
Surface treatment
zinc plated
Surface finish
polished
Connector type
thread connector
Product destination
diameter: 30-30 mm tube
Length
49.5-49.5 mm
Standards
  • AS 1721
  • AS 2052
  • CS 792/S
    • REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      Can I get the 242/32 in orange?

      Yes, the 32mm coupling is available in orange. The part number is 242/32-EO.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=242/32

       

      What is the form number to get a 9012 type G preset from the factory?

      Issue:
      Ordering

      Product Line:
      Industrial Pressure Switches

      Environment:
      9012G

      Cause:
      Preset range and differential settings

      Resolution:
      Add for Y1 to the catalog number and  include the pressure settings  on the markings section in Quote to Cash in order to process the order. ( ie. 9012GBW2Y1 ( 400 FALL- 435 RISE) )

      CTA-ID : 2042032

       

       

      Where are the DC bus connections on a ATV61 drive?

      Issue:
      Where are the DC bus connections on a ATV61 drive?

      Product Line:
      All ATV61/71 drives

      Environment:
      All

      Cause:
      N/A

      Resolution:
      The DC connections are at PA/+ and PC/-.  Please refer to the installation manual for more information.

      Where can I find information on DC bus tying for the ATV71 drives, including wiring diagrams and fuse sizes?

      Issue:
      Where can I find information on DC bus tying for the ATV71 drives, including wiring diagrams and fuse sizes?

      Product Line:
      Altivar ATV71

      Environment:
      All

      Cause:
      Do we have any ATV71 examples of a DC bus tie?

      Resolution:
      See the attachment for wiring examples and fuse tables for the ATV71 drives DC bus tie.
       

      What are possible causes of a web page statistics Overrun fault on an ATV61/71 series drive with Ethernet IP communication card?

      Issue:
      What are possible causes of a web page statistics Overrun fault on an ATV61/71 series drive with Ethernet IP communication card?

      Product Line:
      Altivar 61 / Altivar 71 series drives.

      Environment:
      All models and serial numbers where Ethernet IP option card, part number VW3A3316, is installed.

      Cause:
      Information not available in current documentation.

      Resolution:

      The Overrun counter is a standard Ethernet Diagnostic. The value is provided directly by the Ethernet component used on this card.

      The overrun shows the number of times that the receiver hardware was incapable of handing received data to a hardware buffer because the input rate exceeded the receiver's capability to handle the data.

      This behavior can be observed when a peak of frames appears on the network.
      The origin of the frame peak can be linked to the network load.
      Burst of request could be generated on the network when some device restart or Power ON on the same Ethernet network (like for example PC with proxy server). This type of device initialization generates a lot of broadcast frame on the entire network. These frames will be seen by the drive.

      A point to check will be to make a network analysis in order to have an idea of the network load.

      Then if it appears on only one card:
      Dedicated services are launch only on this card.
      Even if the protocol selected is Ethernet/IP, the card embeds Modbus TCP server (on webserver for example). These Modbus TCP servers stays accessible. PLC or computer (webserver, specialized tool) could send Modbus TCP request to one card.
      So you will have on the same card, CIP implicit exchange + Modbus TCP request. If the rate of those exchanges is really fast, you are in similar condition that burst of request describe before but here only located on one card.
      Card could be defective
      For this it’s needed to replace the card and send back the card for expertise.


      Several verification could be check:
      First check the network load
      On device where you do not see Overrun fault and on device with Overrun counter increasing. This will give several indications
      Compare the Frames load on several drive (one good and the bad one)
      Have an overview of all frames send see by this drive with Overrun counter.

      Swap 2 card
      Take one card where there is no Overrun and swap it with “bad” card.
      If issue follow the card, it will be mandatory to analyze this card. But before analyze, we need to have the result of network measurement, and know what are the service used on this card
      implicit messaging (what is the speed RPI)
      explicit messaging (what frequency)
      Modbus TCP exchange used (if yes what is the frequency)
      Webserver used or not

      Are EasyPact CVS circuit breakers for sale in the USA or Canada?

      Product Line:
      EasyPact CVS circuit breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.

      Will the Compact NSX breaker be for sale in the USA or Canada?

      Issue:
      Where can I buy a Compact NSX breaker?

      Product Line:
      Circuit Breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

      If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

      For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
      https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page