Quantcast

Duo Max TSP 6/50 Box 25 Pcs

Duo Max TSP 6/50 Box 25 Pcs

Duo Max TSP 6/50 Box 25 Pcs

Item Number: 1240001

Retail
$1.97
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Thorsman

Product or component type

cavity fixing

Device application

3-26 mm board material

Colour tint

red/white

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Provided equipment

screw

Mounting support

board material - thickness: 3-26 mm

Mounting support

wall mounted

Quantity per set

set of 25

Net weight

0.0028 kg

Environmental characteristic

corrosion resistance

Ambient air temperature for operation

-40-80 °C

Length

52 mm

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP101028EN

Material

Material

  • screw: steel electroplated
  • collar: PA (polyamide)
  • spring: PA (polyamide)
    • Others

      Number of Units in Package 1

      1

      Package 1 Height

      0.9 cm

      Package 1 Length

      5.3 cm

      Package 1 width

      0.9 cm

      Unit Type of Package 1

      PCE

      Device short name

      TSP

      Thread type

      M3

      Screw diameter

      3 mm

      Screw length

      50 mm

      Drilling diameter

      6 mm

      Practical load capacity

    • shear: 180 N for 13 mm board 4.5 )
    • pull-out load: 70 N for 13 mm board 6 )
    • shear: 240 N for 2 x 13 mm board 4.5 )
    • pull-out load: 90 N for 2 x 13 mm board 6 )
      • Thickness

      • 0-20 mm fixture 13 mm board
      • 0-7 mm fixture 2 x 13 mm board
        • Diameter

          11 mm

          Package 1 Weight

          3 g
          Show all specifications

          Frequently Asked Questions

          hide show

          Concept 2.6. Trying to assign an address to a variable using the format '%I1' produces error message: "Invalid selector of register address Error ID: NCC-19902".

          Open the Concept project and navigate to Options - Preferences and choose IEC format. Once this option is chosen,
          the following rule applies:

          Entering %0x0001 on a pin will display %Q0001 on the block.
          Entering %1x0001 on a pin will display %I0001 on the block.
          Entering %3x0001 on a pin/block will display %IW0001 on the block.
          Entering %4x0001 on a pin/block will display %QW0001 on the block.

          You will find that this will alter the \windows\concept.ini file' [Common] section. AddrStyle=3 will be set.


          Can I use a PDL699TB with a 14470019 modem pack floor socket bracket

          Yes, PDL699TB will suit the 14470019 modem

          How to gear in two LXM28 drives in SoMachine?

          Issue:
          Setup function block GearIn_LXM28 so that the client and server drives follow each other perfectly

          Product Line:
          LXM28

          Resolution:
          The NUM of the GearIn_LXM28 function block should be set to 1280000 and the DENUM should be set to 8192 (2048 x 4).
          This will make the perfect gear between the client and server.

          What is the native resolution of the encoder counts for Lexium 28 servo drives?

          The native resolution for Lexium 28 is 1280000 counts per revolution on the motor.

          This is important to know especially when using the LXM28 in gear mode.
          The factory default ratio for gear mode is 128/10      (128 = numerator  10 = denominator)
          The equates to 128 motor increments for 10 pulses applied to the pulse train input.  


          Rev 10-23-18
           

          What is the factory default scaling on Lexium 28 servo drives?

          The factory default for position scaling is 128 as the numerator and 10 and the denominator.  Parameters P1-44 and P1-45 respectively.
          These values are based on the encoder feedback resolution of 1280000 counts per revolution from the motor.

          With the factory default scaling a commanded move of 100000 will result in the motor shaft making one full revolution.


          rev 7-19-18

           

          PME upgrade times out at 'Create Database' step, fails at 'Verify Databases' step

          Issue
          When upgrading to PME from an earlier version, the 'Create Database' step times out, causing the 'Verify Databases' step to fail.



          Product Line
          Power Monitoring Expert 9.0
          Power Monitoring Expert 2020

          Environment
          Software Upgrade

          Cause
          The default timeout for the 'Create Database' step is 20 minutes for PME 9.0 and 30 minutes for PME 2020. If the databases are large, it can sometimes take longer than 30 minutes to finish upgrading the databases, resulting in this step timing out. Since the database upgrade doesn't complete, the installer does not pass the 'Verify Databases' step.

          Resolution
          *Warning: Take backups of any files prior to modifying them. Ensure the backups are in a location that will not be overwritten (i.e. the Desktop).
          1. Click Exit and close out of the installer
          2. The installation media cannot normally be edited, so either copy the install disc to the hard drive or download and extract the PME installer .iso using a .iso file extractor (e.g. 7-Zip)
          3. Navigate to setup\ BrokerFragments
          4. Right-click > Edit the Database.Core.broker.xml file
          Note: The example below using the values from PME 9.0. The timeout is 1800000 ms for PME 2020.

          If Windows Authentication was used during Database Software step:
          1. Locate the following line, where the current 'TimeOut' is set to 1200000 ms, or 20 minutes: 
          <Request Name="CreateIONDatabasesWindowsAuth" EstTime="500" TimeOut="1200000" UIName="#CreateDatabase" ActionOnFail="Stop">
          1. Change the 'TimeOut' parameter to 12000000 ms, or 200 minutes: 
          <Request Name="CreateIONDatabasesWindowsAuth" EstTime="500" TimeOut="12000000" UIName="#CreateDatabase" ActionOnFail="Stop">
           
          1. Save the Database.Core.broker.xml file
          2. Navigate back to the root directory of the extracted installation media, then right-click MainSetup.exe > Run as Administrator to re-run the installer with the new timeout setting
          If SQL Authentication was used during Database Software step:
          1. Locate the following line, where the current 'TimeOut' is set to 1200000 ms, or 20 minutes: 
          <Request Name="CreateIONDatabasesSqlAuth" EstTime="500" TimeOut="1200000" UIName="#CreateDatabase" ActionOnFail="Stop">
          1. Change the 'TimeOut' parameter to 12000000 ms, or 200 minutes: 
          <Request Name="CreateIONDatabasesSqlAuth" EstTime="500" TimeOut="12000000" UIName="#CreateDatabase" ActionOnFail="Stop">
           
          1. Save the Database.Core.broker.xml file
          2. Navigate back to the root directory of the extracted installation media, then right-click MainSetup.exe > Run as Administrator to re-run the installer with the new timeout setting
          Show More