box junct galv l/d 25mm 3way

Cable Management Machine Cast Fittings, Junction Boxes and Lid Kits, 25mm, 3 Way

Catalogue Number: 1240/25/3
box junct galv l/d 25mm 3way
Retail
$128.26
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Range of product
Saturn Series
Material
cast iron
Depth
40 mm
Shape
round
Surface treatment
galvanised
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
819 g
Package 1 Height
4.6 cm
Package 1 width
10 cm
Package 1 Length
10 cm
Unit Type of Package 2
BB1
Number of Units in Package 2
10
Package 2 Weight
8.304 kg
Package 2 Height
11.4 cm
Package 2 width
19.2 cm
Package 2 Length
25.2 cm
Unit Type of Package 3
PAL
Number of Units in Package 3
1120
Package 3 Weight
873.6 kg
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Frequently Asked Questions

hide show

What is the part number for a plug to suit the 240/25?

The part number for a plug to suit the 240/25/3 is a 220/25.
 

Does the 1240/25 series come with gaskets?

No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
For more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=1240

Whati s pitch thread for part number 1245/25?

Pitch thread is 1.5mm

What is the part number of a Junction box with 25mm entry but entries in U shape?

Unfortunately we dont make U entry junction box any more, closest will be 240/25/2A and similar.

What is part number for lid to suit 1239/20/4?

Part number 1239L20 will suit any of 1239/20 series.

Where are the CT/VT ratios set for a VAMP relay in VAMPSET?

The CT/VT ratios are set under the S C A L I N G label.

Sur le document suivant, PublicDocument Author Bertrand Guarinos Created : 12/09/2003 Sur le document suivant sur le site STIE-GHD. Title ...

Goals and Symptoms

Sur le document suivant,

PublicDocument
Author Bertrand Guarinos Created : 12/09/2003
Sur le document suivant sur le site STIE-GHD.
Title ATV11 line fuses list
Category d - PRODUCTS\ATV11\Maintenance, d - PRODUCTS\ATV11\Technical information.
e - Maintenance-Repair\ATV11.
Public.

figure deux types de fusible possibles à placer en tête d'alimentation des ATV11.
Où puis-je trouver la définition des classes fusible CC et J?
D'autre par pour qu'elle raison la valeur du courant assigné des fusibles rapides ou retardé en classe J est le même?
Voir document en attachement.

Causes and Fixes

Il s'agit de deux standards américains, protection au toucher pour le J et l'encombrement réduit pour le CC.

plus d'infos sur : https://www.ferraz-shawmut.com/fr/PRODUCTS/gen_nord_americain.html

What does FUN 41 mean on a Model 50 Hand Held Programmer?

FUN 41 is a function code for the hand held programmer.
FUN41 is shutdown / auto-restart mode selection.

If set to 0, it will be in shutdown mode
If set to 1, it will be in auto-restart mode.

What size fuses are used in the ATS48 for the control circuit going to CL1 and CL2?

Issue:
What size fuses are used in the ATS48 for the control circuit going to CL1 and CL2?

Product Line:
Altistart 48, ATS48

Environment:
All open style units.  All models, All Serial numbers.

Cause:
Selection of Fuses.

Resolution:

ATS48D17Y and ATS48D22Y we recommend Class CC 600V 0.5 A fuses.

ATS48D32Y, ATS48D38Y, ATS48D47Y, ATS48D62Y, ATS48D75Y, ATS48D88Y, ATS48C11Y, ATS48C14Y, and ATS48C17Y we recommend Class CC 600V 0.6 A fuses.

ATS48C21Y, ATS48C24Y, and ATS48C32Y we recommend Class CC 600V 1.0 A fuses.

ATS48C41Y, ATS48C48Y, ATS48C59Y, ATS48C66Y, ATS48C79Y, ATS48M10Y and ATS48M12Y we recommend Class CC 600V, 1.5 A fuses.

Information provided in Table 31 page 83) of document S1A37491 Altistart 48 Y-range Soft Start Controllers Instruction Bulletin.

StruxureWare Power Monitoring 7.0 - Why do I see 'an unexpected error has occurred' when I try to add a Report Subscription in Web Reporter?

Issue
If StruxureWare Power Monitoring 7.0 is installed as a distributed system, that is, there is both a database server and an application server and Reporting Services is installed on the database server, you will not be able to create a report subscription.. When an attempt is made to add a report subscription, in the Web Reporter UI, the user will see a screen that says ''unexpected error has occurred. Your request cannot be processed at this time. If the problem persists, contact the Webpage administrator'.

If you look in the EventException table, the following will be displayed:

System.ApplicationException: Could not authenticate. at PowerMeasurement.Security.UserImpersonator..ctor(String username, String password, String domain) at PowerMeasurement.Apps.Web.EEM.Modules.Reports.AddRSReportSubscription.InitPrinterControl() at PowerMeasurement.Apps.Web.EEM.Modules.Reports.AddRSReportSubscription.Page_Load(Object sender, EventArgs e) at System.Web.Util.CalliHelper.EventArgFunctionCaller(IntPtr fp, Object o, Object t, EventArgs e) at System.Web.Util.CalliEventHandlerDelegateProxy.Callback(Object sender, EventArgs e) at System.EventHandler.Invoke(Object sender, EventArgs e) at System.Web.UI.Control.OnLoad(EventArgs e) at System.Web.UI.Control.LoadRecursive() at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)

Product Line
StruxureWare Power Monitoring (SPM) 7.0 or 7.0 to 7.0.1 Upgrade

Cause
This problem results because the IONUser windows account is not created on the application server at install time.

Resolution
The workaround is to add the IONUser Windows account manually. The password should be set to 'IONisgreat!' without the single quotes.. Most of the time, It does not need to be a member of any group. However, if the same error message shows up again, adding the IONUser to the Administrators group can correct the error.

This problem has been addressed in Struxureware Power Monitoring 7.0.1, but only on new installations. SPM 7.0 systems that are upgraded to SPM 7.0.1 will need to have the IONUser added to the application server manually.

Is there an alternative for 1239/20/1, Round, 20mm, 1 Way Entry, Light Duty Junction Box?

 Yes, however the alternatives may vary in style, material or number of entries.

The closest alternative in galvanised cast iron is a Junction Box, Round- 20mm I.D, 1 Way Entry, Heavy Duty. The Part number is 1239H20/1.
The closest alternative in PVC is a Junction and Adaptable Boxes PVC- 20mm Entries, 1 Way. The partn number is 240/20/1.

For further information please visit https://www.clipsal.com/Trade/searchround/jbox20MMENTRY1