box junction galv 20mm 3way

Cable Management Machine Cast Fittings, Junction Boxes And Lid Kits, 20Mm, 3 Way

Catalogue Number: 1239/20/3
box junction galv 20mm 3way
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Saturn Series
Material
cast iron
Depth
30 mm
Shape
round
Surface treatment
galvanised
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is part number for lid to suit 1239/20/4?

Part number 1239L20 will suit any of 1239/20 series.

Is there a 32A version of the 1439/20?

No, 20A is the largest size in this model plug.

What size fuses are used in the ATS48 for the control circuit going to CL1 and CL2?

Issue:
What size fuses are used in the ATS48 for the control circuit going to CL1 and CL2?

Product Line:
Altistart 48, ATS48

Environment:
All open style units.  All models, All Serial numbers.

Cause:
Selection of Fuses.

Resolution:

ATS48D17Y and ATS48D22Y we recommend Class CC 600V 0.5 A fuses.

ATS48D32Y, ATS48D38Y, ATS48D47Y, ATS48D62Y, ATS48D75Y, ATS48D88Y, ATS48C11Y, ATS48C14Y, and ATS48C17Y we recommend Class CC 600V 0.6 A fuses.

ATS48C21Y, ATS48C24Y, and ATS48C32Y we recommend Class CC 600V 1.0 A fuses.

ATS48C41Y, ATS48C48Y, ATS48C59Y, ATS48C66Y, ATS48C79Y, ATS48M10Y and ATS48M12Y we recommend Class CC 600V, 1.5 A fuses.

Information provided in Table 31 page 83) of document S1A37491 Altistart 48 Y-range Soft Start Controllers Instruction Bulletin.

What is the difference between the SyMax 8030PS25/35 power supplies and the 8030PS25F/35F power supplies?

The PS25F and PS35F power supplies are identical in function to the PS25 and PS35 modules, except that they do not have an ON/OFF switch located on the front of the module. A separate main disconnect switch or circuit breaker must be installed to shut off power to the programmable controller system.


NOTE: The Sy/Max product line was obsoleted 12/31/2013 and the recommneded upgrade is the M580, contact your local distributor or SchneiderElectric for more information.

Sur le document suivant, PublicDocument Author Bertrand Guarinos Created : 12/09/2003 Sur le document suivant sur le site STIE-GHD. Title ...

Goals and Symptoms

Sur le document suivant,

PublicDocument
Author Bertrand Guarinos Created : 12/09/2003
Sur le document suivant sur le site STIE-GHD.
Title ATV11 line fuses list
Category d - PRODUCTS\ATV11\Maintenance, d - PRODUCTS\ATV11\Technical information.
e - Maintenance-Repair\ATV11.
Public.

figure deux types de fusible possibles à placer en tête d'alimentation des ATV11.
Où puis-je trouver la définition des classes fusible CC et J?
D'autre par pour qu'elle raison la valeur du courant assigné des fusibles rapides ou retardé en classe J est le même?
Voir document en attachement.

Causes and Fixes

Il s'agit de deux standards américains, protection au toucher pour le J et l'encombrement réduit pour le CC.

plus d'infos sur : https://www.ferraz-shawmut.com/fr/PRODUCTS/gen_nord_americain.html

Is there an alternative for 1239/20/1, Round, 20mm, 1 Way Entry, Light Duty Junction Box?

 Yes, however the alternatives may vary in style, material or number of entries.

The closest alternative in galvanised cast iron is a Junction Box, Round- 20mm I.D, 1 Way Entry, Heavy Duty. The Part number is 1239H20/1.
The closest alternative in PVC is a Junction and Adaptable Boxes PVC- 20mm Entries, 1 Way. The partn number is 240/20/1.

For further information please visit https://www.clipsal.com/Trade/searchround/jbox20MMENTRY1



             1239/20/1                          1239H20/1                           240/20/1                           



 

What is the part code for the cord connector to suit the PDL56P320F?

We do not do one this size and with flat pins in 56 series
clipsal option (not IP rated)
438/20-WE - extention socket 20A
1439/20 - 20A plug
 

StruxureWare Power Monitoring 7.0 - Why do I see 'an unexpected error has occurred' when I try to add a Report Subscription in Web Reporter?

Issue
If StruxureWare Power Monitoring 7.0 is installed as a distributed system, that is, there is both a database server and an application server and Reporting Services is installed on the database server, you will not be able to create a report subscription.. When an attempt is made to add a report subscription, in the Web Reporter UI, the user will see a screen that says ''unexpected error has occurred. Your request cannot be processed at this time. If the problem persists, contact the Webpage administrator'.

If you look in the EventException table, the following will be displayed:

System.ApplicationException: Could not authenticate. at PowerMeasurement.Security.UserImpersonator..ctor(String username, String password, String domain) at PowerMeasurement.Apps.Web.EEM.Modules.Reports.AddRSReportSubscription.InitPrinterControl() at PowerMeasurement.Apps.Web.EEM.Modules.Reports.AddRSReportSubscription.Page_Load(Object sender, EventArgs e) at System.Web.Util.CalliHelper.EventArgFunctionCaller(IntPtr fp, Object o, Object t, EventArgs e) at System.Web.Util.CalliEventHandlerDelegateProxy.Callback(Object sender, EventArgs e) at System.EventHandler.Invoke(Object sender, EventArgs e) at System.Web.UI.Control.OnLoad(EventArgs e) at System.Web.UI.Control.LoadRecursive() at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)

Product Line
StruxureWare Power Monitoring (SPM) 7.0 or 7.0 to 7.0.1 Upgrade

Cause
This problem results because the IONUser windows account is not created on the application server at install time.

Resolution
The workaround is to add the IONUser Windows account manually. The password should be set to 'IONisgreat!' without the single quotes.. Most of the time, It does not need to be a member of any group. However, if the same error message shows up again, adding the IONUser to the Administrators group can correct the error.

This problem has been addressed in Struxureware Power Monitoring 7.0.1, but only on new installations. SPM 7.0 systems that are upgraded to SPM 7.0.1 will need to have the IONUser added to the application server manually.

What is the minimum firmware requirements for Powerlogic meters in StruxureWare Power Monitoring Expert?

Issue
What is the minimum firmware requirements for Powerlogic meters in StruxureWare Power Monitoring Expert?

Product Line
Powerlogic meters
StruxureWare Power Monitoring Expert 7.0.x
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.0
Power Monitoring Expert 8.1
Power Monitoring Expert 8.2

Environment 
Power Monitoring Expert Software Configuration

Resolution
It is strongly recommended to upgrade the firmware to the recommended levels to rule out any potential issues. Below are minimum firmware requirements that SPM/PME will support.

Device Type Firmware Version(s)
PM810/PM820/PM850 10.6
PM870 10.7
CM3xxx 14.35
CM4xxx 14.34
PM750 3.02
PM700/PM700P/PM720 3.01
MicroLogic H 8.261 (Logic2005AF)
MicroLogic P 8.261 (Logic2005AF)
MicroLogic A No change in the last five years
MicroLogic Communications Module Use in type A, P, and H = 2.001
CM2050/CM2150/CM2250/CM2452 17.xxx
CM2350/CM2450 16.xxx
PM600 12.004
PM620 12.002
PM650 22.7
Momentum PLC D16 (EPSS) 1.01
Momentum PLC A8 (WAGES) 3.03
Momentum PLC D10 (WAGES) 3.03


NOTE: SPM can still support older firmware versions. However, some registers might be supported on those versions; and thus they may cause “n/a” or nonexistent measurement displays.
CM2 OS firmware version 14 (and older) has a Y2K issue that affects correct operation in the software. You should upgrade to the latest version.
Vista diagrams may not open correctly if older firmware versions are used. Contact Technical Support for assistance.

What is the part# for our RS232 to RS485 converter?

Part# XGSZ24

what is the replacement or how can be make up a MSWSL1000-BK ?

we need to build it up MSWALFE1000-BK + 1439/20-TR PLUG

what is the part no for a plug like 439 which is 20A rated?

the part no is 1439/20

please use this link for further information https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=1439/20

User-added image

Is there a CAD drawing for BMEP M580?

Please see attached a 2D drawing.

MiCOM P52x manual

See attached for the MiCOM P521, P522, and P523 manual.
MiCOM P521 Manual_A83.pdfMiCOM P521 Manual_A83.pdf

How to control an ATV61 / ATV71 with a M340 CPU built-in Ethernet port using the DATA_EXCH function

The attached document describes an application using a M340 CPU with a built-in Ethernet port connected to an ATV71 Ethernet card VW3A3310D and using the DATA_EXCH function. The M340 will be communicating with the IO Scanner service in the drive.
 

What is the part number for a metal conduit J-Box with 1 x 20mm entry?

The part number for a metal conduit J-Box with 1 x 20mm entry is - 1239/20/1

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=1239/20/1
User-added image

Where are the CT/VT ratios set for a VAMP relay in VAMPSET?

The CT/VT ratios are set under the S C A L I N G label.

What would cause a Quantum 140CPS11100 power supply to not power up?

The Quantum 140CPS11100 power supply that has a PV 01 or higher now require a jumper on pins 3 and 4 on the terminal strip for 115 VAC operations. If this jumper is not installed, it will be set for 220 VAC operations. Any power supply with a PV less than 1 did not require the jumpers.

Note: The Quantum line is obsolete 12/1/2018 and the recommended replacement is the M580 with the x80 I/O, for further information on this contact your local distributor.


STBXTS5610 Connector Pinouts

Goals and Symptoms

The purpose of this resolution is to document pinouts for the STBXTS5610 HE10 connector used with the STBDDO3705 16 Channel Output module.

Facts and Changes



Causes and Fixes

See Facts and Changes for connector pinouts.

SoMachine Basic 1.6 FTP download link.

Issue:
Where to find and download SoMachine Basic.

Product Line: 
SoMachine Basic

Environment:
SoMachine Basic

Resolution:
As of 10/9/2018 the SoMachine Basic software is version 1.6 sp2 and below is the free download FTP link for it. 
https://www.schneider-electric.com/en/download/document/SoMachineBasicV1.6SP2/

Note: As of 2/1/2019  SoMachine Basic is now called EcoStruxure Machine Expert Basic 

Can my XW+ inverter qualify an input of 120V/208V 60Hz?

XW+ inverters input parameters

The XW+ and XW inverters, either the XW6848, XW5548, XW6048, XW4548 or the XW4024, require an input of 120V/240V 60Hz. When the input is 120V/208V 60Hz, is going to be a three phase setup. The reason for this is because the XW+ and XW unit require a phase difference between line 1 (L1) and line 2 (L2) of 180 degrees, on a three phase setup, L1 and L2 are 120 degrees offset. This causes the inverter to not recognize the input at all. The inverter can only accept input from 120/208V wye source if you have 3 inverters (1 per phase), each "converted" to 120V, and then configured for 3-phase multi-unit operation.

Single Phase Diagram:



Three Phase Diagram:


 

What is the replacement for my Connexium 5 port unmanaged switch part number 499NES25100?

The replacement would be the Connexium unmanaged 5 port switch part number TCSESU053FN0


Legacy KB System (APS) Data: RESL199233 V1.0, Originally authored by MiMe on 06/26/2009, Last Edited by MiMe on 06/26/2009
Related ranges: ConneXium - Ethernet

Is Topological Addressing supported on the Quantum ERIO network?

No. Topological Addressing is not supported on the Quantum ERIO network. This includes Quantum or X80 EIO drops.





R-3162018



 

What does FUN 41 mean on a Model 50 Hand Held Programmer?

FUN 41 is a function code for the hand held programmer.
FUN41 is shutdown / auto-restart mode selection.

If set to 0, it will be in shutdown mode
If set to 1, it will be in auto-restart mode.

Is it possible to change the IONUser password?

Issue

As of ION Enterprise 6.0, a Windows user account is used to operate the reporting functionality. The default username and password for this account are IONUser and IONisgreat!, respectively. This article describes the required actions to change the IONUser password.

Product Line
ION Enterprise 6.0
Struxureware Power Monitoring (SPM) 7.0.x
Power Monitoring Expert (PME) 7.2.x, 8.x

Resolution

WARNING: This direct modification of the database is potentially harmful to your system and can result in system being inoperative and/or loss of data if below instructions are followed improperly. Always use extreme caution before executing such actions and make sure to backup the databases before you start.

The IONUser account is used to authenticate the report server. To properly change the password of the IONUser, the password must be updated in the following three places:

  1. Open either Server Manager or Computer Management and navigate to Local Users and Groups > Users. Locate the IONUser user and apply the new password.
  2. Note: For 6.0 and 7.0 systems only. Open SQL Server Management Studio > Security > Logins. Right-click on IONUser and select Properties. Update the password and press OK.
  3. Use one of the following methods to update the ION_Network database:
Method 1: Manually changing the CFG_ItemValue table

In SQL Server Management Studio, navigate to the ION_Network database > CFG_ItemValue table. The password can be changed directly in the table but it is not trivial which row corresponds to IONUser as there is only a reference to ItemID.
  1. From CFG_Item table find the row with 'subscriptionDeliveryPassword' under 'ItemName' column. Make a note of the ItemID value.
    • In IONE 6.0 and SPM 7.0.1, the itemID = 33
    • In PME 7.2.2, the itemID =42
    • In PME8, the itemID = 43
  2. Edit the CFG_ItemValue table to contain the new password at the row specified by the ItemID.

Method 2: Running SQL script to change the CFG_ItemValue table

  1. Open SQL Server Management Studio
  2. Open a new query editor window
  3. Run the following query against ION_Network. Replace  in the query below by the actual password. Make sure to keep the single quotes.

UPDATE CFG_ItemValue SET [Value] =''
WHERE ItemID in(
SELECT ItemID
FROM CFG_Item
WHERE ItemName IN ('reportServerPassword','subscriptionDeliveryPassword'))

  1. Verify the password has been changed properly by running this query:

SELECT i.ItemName, i.Description, iv.Value, iv.DefaultValue 
FROM CFG_Item i INNER JOIN
CFG_ItemValue iv ON
i.itemID = iv.itemID
WHERE i.ItemName IN ('reportServerPassword','subscriptionDeliveryPassword')

 
The IONUser credentials are cached. You will also have to restart the following services for the changes to take effect:
  • ION Report Subscription Service
  • World Wide Web Publishing Service
  • Report Server Service (only SPM 7.0.1 and below) 
The Database Manager retrieves the username and password from the same place as the reporting platform. Restart Database Manager if it was left open during the password update for changes to take effect.

What is the communication cable to connect a Magelis XBTN401 to a Twido TWDNAC485D MiniDin port?

The cable part number is XBTZ968.


Note: The Twido is obsolete as of 12/31/2016 and the direct replacement for this is the M221 product and it has a RJ-45 port and not a mini din.

Can the Twido support an SSI absolute encoder?

No, the Twido does not support the SSI absolute encoder. The Twido will support one of the following, up/down, up/down 2 phase counter, single up, single down, frequency meter.

Note: The Twido product line was obsolete 12/31/2016 and has been replaced by the M221 product line.

Does Schneider offer a conversion tool which will allow me to migrate 800 Series I/O to Quantum, without rewiring my I/O?

Yes. Please see attached PDF file. 800_to_Quantum.pdf


Note: The Quantum seried will be obsoleted 12/31/2018 and the new upgrade option for the 800 series will be the M580 with the X80 I/O and that also has conversion kit to go from 800 to x80.


Rev 7/7/2017

What is the correct stripped exec to load into a Quantum 140CPUX130X when using Concept 2.6?

The PV version of the 140CPUX130X will determine what firmware you will need.

If the PV is < PV06, it is Q1SV248E.BIN.
If the PV is => PV06,  it is Q1RV301E.BIN.


Note:  The Quantum 140CPUX130x is obsolete and has been replaced with the Unity Quantum which will be obsoleted 12/31/2018 and the upgrade recommendation would be to use the M580 and import the program into the Unity Pro software.

Can a Twido TWDLCAA40DRF controller have a Memory cartridge and a Real Time Clock chip (RTC) installed?

Yes. The Twido TWDLCAA40DRF has a "built-in" RTC chip so you do not need to add the chip. As for the memory chip, this would only be needed if you want to save the program to it and it would not remain in the controller. It also has an option to add an external battery to hold the program when it is powered down.


Note: The Twido Line is obsolete as of 12/31/2015 and has been replaced by the M221 family, for more information on this contact your local distributor or Schneider Electric Sales office. 

Where Can I find EM4200 Enercept Meter Documents?

Product Line
EM4235
EM4236


Environment
EM4200 Documentation

Resolution
All EM4200 meters documents can be found at the following link:

https://shoppingkiosk.schneider-electric.com/list_documents.aspx?navid=63381


The documents current of 1/29/2016 are attached to this article.

NOTE: For Modbus registers list: downloand EM4200_Modbus_RegisterMap.xlsx
NOTE
: For BACnet objects list: downloand EM4200_BACnet_ObjectList.xlsx 
 

How do I flash the executive firmware to the 174CEV30020 bridge?

The Walusoft TFTP Client software utility is used to flash the executive firmware to the CEV 300 20.
https://www.walusoft.co.uk/download.htm


Legacy KB System (APS) Data: RESL169367 V1.0, Originally authored by on , Last Edited by on
Related ranges: ConneXium - Ethernet

Does the M340 BMXPRA0100 support the Global Data service?

Title

Issue
Does the M340 BMXPRA0100 support the Global Data service
 
Product Line
M340
 
Environment
Unity Pro
 
Cause
N/A
 
Resolution
The M340 BMXPRA0100 does not support the Global Data service

 

What is the execution time for a list instruction for Twido?

The execution time for a Twido list instruction is 0.14 micro seconds to 0.9 micro seconds.

 
NOTE: TheTwido line has been obsoleted as of 12/31/2016 and has been replaced with the M221 family with the SoMachine Basic software.

 

Is the Twido TWDLCAE40DRF Marine Certified?

No. The Twido TWDLCAE40DRF is not Marine Certified and will not be per engineering.

Note: The Twido line was obsoleted 12/31/2016 and was replaced by the M221 product family does have Marine certification.

If the power is removed from the Twido PLC, will the Real Time Clock part number TWDXCPRTC, continue to be updated?

Yes. Using a fully charged battery the time will continue to be updated for 1000 hours at 25 degrees C or 300 hours at 55 degrees C .


Note: The Twido PLC line was obsolete 12/31/2016 and has been replaced with the M221 product line.

What is the minimum clearance for mounting Twido Controllers in a cabinet?

Minimum Clearances for a Compact Controller and Expansion I/O Modules. In order to maintain a natural circulation of air around the Compact controller and expansion I/O modules in a control panel, observe the minimum clearances shown in the figures below.

Minimum Clearances for a Modular Controller and Expansion I/O Modules. In order to maintain a natural circulation of air around the Modular controller and expansion I/O modules in a control panel, observe the minimum clearances shown in the figures below.

 


Note: Twido was made obsolete 12/1/2015 and has been replaced with the M221. The Twido program can be imported into the M221 SoMachine Basic software and the dimensions are the same for the M221 as the Twido. For further information on this contact your local distributor or Schneider sales office.

Can I add a 2nd serial communication port to a Modular Twido?

Yes. With the Modular Twido you can add an expansion module to it for a second serial communication port.
There are 3 different types expansion modules available:

TWDNOZ232D RS232 mini din connector
TWDNOZ485D RS485 mini din connector
TWDNOZ485T RS485 terminal connector

Note: The Twido line was obsoleted 12/31/2016 and was replaced with the M221 family, this has a USB, serial and Ethernet port depnding on the model and also can add a secondary port if still needed.

 

Will Dynamic Host Configuration Protocol (DHCP) requests pass through a router?

DHCP requests sent by the client device, or client computer are broadcasts. Routers do not pass broadcasts through to other networks. This prevents a broadcast problem on one network from propagating to another. To use DHCP across a routed network, a DHCP/ BOOTP relay agent must be employed (RFC 1542). ( DHCP is an extension of the bootstrap protocol (BOOTP), refer to RFC 951).
A relay agent is a program used to pass specific types of IP packets between subnets. A DHCP/BOOTP relay agent simply passes DHCP/BOOTP messages (IP packets) from one subnet to another. It can be software or hardware based. Some routers are RFC 1542-compliant. These have an agent built in to them.


Legacy KB System (APS) Data: RESL1205 V1.0, Originally authored by on , Last Edited by on
Related ranges: ConneXium - Ethernet

What are the dip switches (RM and Stand by) used for on the ConneXium Ethernet Managed Switches?

The following table shows the states and meanings for the dip switches on the ConneXium Ethernet Managed Switches.


Note: If the Dip switches were not both set to 1 before the initial power up of the switch then all software settings for Redundancy will be greyed out and the default port settings will be use.
At this point to make the redundancy settings available the switch configuration needs to be erased and the switch need to have both Dip switched set to 1 upon power up.


Recommendation on when a reboot of the NIP2212 may be required

Goals and Symptoms

Recommendation on when a power cycle of the 'STB NIP2212' may be required to recover from a fault
condition shown in the status word.

Facts and Changes

'STB NIP2212'

Causes and Fixes


The following is recommendation on when a power cycle of the NIP2212 may be required to
recover from a fault condition that is shown in the status word.

  • A power cycle of the NIM may be required if, the bit for condition 'D9' (internal failure) is set in the
status word as described in the online help. 'D9' will get set when there is a global error. (i.e., if a
mandatory module is missing.)
  • Depending on the situation, some global errors may require a power cycle to restart the NIM or
island after the error condition has corrected.
  • Bit error conditions 'D8' and 'D10' may or may not require a power cycle.

Note: If the error condition can be corrected without power cycling the NIM, the error bit will get reset.

Can the password protection for my Twido application be removed?

Yes. In order to remove the password, you will need to know the old password. To remove password protection from an application, you
will need to do the following:

 

1.
Open the application that has been password protected using the current password.
2.
Select Program - Change Password from the main menu.
3.
Type the current password in Enter Old Password. Do not enter a password in "New Password " field, tab through the other boxes.
4.
Select OK to close the box.

The application must be saved to remove password protection.

Note: The Twido line has been obsoleted 12/31/2016 and has been replaced with the M221 line.

What is the difference between the 140XTS00206 and the 140XTS01206?


140-XTS-002-xx cable is rated for .5 Amps per point (read as point 5 Amps)
140-XTS-012-xx cable is rated for 2 Amps per point (read as 2 Amps)

The following table outlines the different Cablefast cables, their description, and rating:

140 XTS 002 03 3 foot cable with sub "D" connector Standard power .5 Amps
140 XTS 012 03 3 foot cable with sub "D" connector High power 2 Amps
140 XTS 002 06 6 foot cable with sub "D" connector Standard power .5 Amps
140 XTS 012 06 6 foot cable with sub "D" connector High power 2 Amps
140 XTS 002 09 9 foot cable with sub "D" connector Standard power .5 Amps
140 XTS 012 09 9 foot cable with sub "D" connector High power 2 Amps
140 XTS 002 12 12 foot cable with sub "D" connector Standard power .5 Amps
140 XTS 012 12 12 foot cable with sub "D" connector High power 2 Amps
140 XTS 102 06 6 foot cable with pigtail leads High power 2 Amps
140 XTS 102 15 15 foot cable with pigtail leads High power 2 Amps




R-82117


Note: the quantum line will be going obsolete 12/31/2018 and the M580 is the recommended replacement.

READ_VAR or WRITE_VAR does not re-establish communications after re-connecting cable.

Goals and Symptoms

READ_VAR or WRITE_VAR does not re-establish communications after re-connecting cable.

Causes and Fixes

The READ_VAR or WRITE_VAR does not re-establish communications after re-connecting the
Ethernet TCP/IP cable.

This will occur if the communications timeout is left at the default value of zero (0). A timeout value of
zero 0) will cause the function block to never timeout. This results in the The READ_VAR and
WRITE_VAR block to never close the TCP/IP connection when the Ethernet cable is disconnected
and re-connected. The PLC will need to be stopped and re-started after the Ethernet TCP/IP cable
is re-connected.

(If you can get online and change the slave ip address of the block, build changes, then  change it back
to the wanted address, build changes again, this will also get it to reestablish communications)

To resolve the issue, define a timeout value in the '%MW+2' management word of the READ_VAR
or WRITE_VAR block.
 

What are the Twido TWDXPCRTC Real Time Clock option adapter specifications?

Issue:
Twido RTC specifications.

Product line:
Twido

Environment:
TwidoSoft or TwidoSuite

Cause:
Information on the different specifications on back up and charging time.

Resolution:
The below chart is for the Twido TWDXCPRTC Real Time Clock specifications.

ACCURACY
30 s/month (typical) at 25 DEG C (77 deg.F)
Backup duration Approximately 30 days (typical) at 25 Deg. C (77 deg.F) after backup battery fully charged.
Battery Lithium secondary battery
Charging time Approximately 10 hours for charging from 0% to 90% of full charge
Replaceable Can Not replace battery

Note: The Twido was obsolete 12/31/2016 and was replaced with the M221 and the M221 has a replaceable battery.
 

How do you add an AS-i device in TwidoSuite?

Goals and Symptoms

Step by step instructions to ad in an AS-i device using TwidoSuite

Causes and Fixes

How to add AS-I device from a catalog.
Once the program is open and you are in the configuration tab and the TWDNOI10M3 has been added to the Controller, double click on the TWDNOI10M3 and the following will show.



Insert from catalog button on the bottom of the screen or you can also select the button to the left of it to add to catalog. You will also need to select the address of the AS-i device for the module configuration.








Select the family and the device to see the following information on the right side for the device that was selected.



The following information will now give the Permanent characteristics along with the Profile and addressing.


NOTE:  Twido is obsolete as of 12/31/2016 and is replaced with the M221 family and the M221 does not support the AS-i protocol and is recommended o replace with Ethernet or RS-485.

How do you configure a Run/Stop bit in TwidoSuite for a Twido Controller?

Goals and Symptoms

To show how to configure a Run/Stop bit for a Twido Controller using TwidoSuite.

Causes and Fixes

To be able to set up a Run/Stop bit in using TwidoSuite you will need to do the following steps.
Open the program and go to program and configure tab.



At this point depending on what controller that you have selected you will have an input that you can configure as a Run/ Stop bit. This will be an input between %I0.0 to %I0.23 depending on the model number. Select the input that you want to be the Run/Stop bit.



Once you have selected and download this into the controller your first input will control your Run/Stop. In this case it will be %I0.0.


Note: the Twido has been obsoleted 12/31/2016 and has been replaced with the M221, The M221 has a start/stop switch on the front of every M221.

Changing the 'Power Flow Lne Width' causes 'ProWORX 32' to close.

Goals and Symptoms

Changing the 'Power Flow Lne Width' causes 'ProWORX 32' to close.

Facts and Changes

ProWORX 32 version 2.1, Service Pack

Causes and Fixes

Changing the 'Power Flow Lne Width' using the up or down arrows in the Logic Properties window
causes 'ProWORX 32' to close.


The following workaround can be used to change the line width without using the up or down arrows:

  • Click on the textbox next to the 'Power Flow Line Width' to highlight the text..
  • Change the value within the textbox to a number between 1 and 6.
  • Click on the 'Apply button.
  • Click on 'OK' to close the properties window.


This problem has been fixed in Patch A for Service Pack 1. Patch A is expected to be released near the end of Q2/09.




 

Note: Proworx software was obsoleted 12/31/2016 and upgrading to he new hardware and Unity Pro is recommended.

What is the maximum number of PDO's that you can put in a Twido CANopen Master TWDNCO1M?

Issue:
Max number of PDO for the Twido.

Product line:
Twido

Environment:
TwidoSuite, TwidoSoft

Resolution:
The RPDO or TPDO is a 64-byte object that can contain up to eight 8-byte word objects or four 16-byte word objects or any combination of those two types of word objects, not too exceed the overall 64-byte limit of the PDO.
To customize the PDO mapping, select the Mapped Object you wish to modify.
Note: You can not add a 32 byte object into the PDO.

NOTE: The Twido is obsolete 12/31/2016 and has ben replaced with the M221 and the M221 does not support CANopen.
 
 

How long can a Twido hold the program when powered down without an external battery?

 

All bases: By lithium internal battery. Backup duration is approximately 30 days (typically) at 25°C (77°F) after battery is fully charged. It take 15 hours to obtain 0 to 90% of the full battery charge. Battery life is 10 years when charged for 9 hours and discharged for 15 hours. The battery cannot be replaced.

40DRF compact bases: By user replaceable lithium external battery (in addition to internal battery onboard). Backup duration is approximately 3 years (typically) at 25°C (77°F) under normal operating conditions of the base (typically, no long-term powering off of the base). BAT LED on front-panel provides indication of battery power status.

Note: The Twido was obsoleted 12/31/2016 and was replaced by the M221.
Show More